Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

Joerss, Hanna; Apel, Christina; Ebinghaus, Ralf (2021): Per- and polyfluoroalkyl substances (PFASs) in surface water of the North and Baltic Seas in 2016/2017 [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.927756

Always quote citation above when using data! You can download the citation in several formats below.

Published: 2021-02-10DOI registered: 2021-04-27

RIS CitationBibTeX Citation ShareShow MapGoogle Earth

Related to:
Joerss, Hanna; Apel, Christina; Ebinghaus, Ralf (2019): Emerging per- and polyfluoroalkyl substances (PFASs) in surface water and sediment of the North and Baltic Seas. Science of the Total Environment, 686, 360-369, https://doi.org/10.1016/j.scitotenv.2019.05.363
Coverage:
Median Latitude: 54.107058 * Median Longitude: 10.143501 * South-bound Latitude: 53.448000 * West-bound Longitude: 7.126333 * North-bound Latitude: 54.887450 * East-bound Longitude: 14.543650
Date/Time Start: 2017-06-06T06:06:00 * Date/Time End: 2017-09-10T15:10:00
Minimum DEPTH, water: m * Maximum DEPTH, water: m
Event(s):
LP20170606_1WS * Latitude: 53.448000 * Longitude: 10.089000 * Date/Time: 2017-06-06T06:06:00 * Campaign: LP20170606 * Basis: Ludwig Prandtl * Method/Device: Water sample (WS)
LP20170606_2WS * Latitude: 53.537633 * Longitude: 10.002850 * Date/Time: 2017-06-06T08:28:10 * Campaign: LP20170606 * Basis: Ludwig Prandtl * Method/Device: Water sample (WS)
LP20170606_5WS * Latitude: 53.547167 * Longitude: 9.877383 * Date/Time: 2017-06-06T09:26:42 * Campaign: LP20170606 * Basis: Ludwig Prandtl * Method/Device: Water sample (WS)
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
1Event labelEventJoerss, Hanna
2Campaign of eventCampaignJoerss, Hanna
3Latitude of eventLatitudeJoerss, Hanna
4Longitude of eventLongitudeJoerss, Hanna
5Date/Time of eventDate/TimeJoerss, Hanna
6DEPTH, waterDepth watermJoerss, HannaGeocode
7Perfluorobutanoic acidPFBAng/lJoerss, HannaSolid-phase extraction (SPE) and cleanup, coupled liquid chromatography tandem mass spectrometry (LC-MS/MS)measured in water column, limit of detection for LP20170606: 0.16 ng/l, limit of quantification for LP20170606: 0.35 ng/l, limit of detection for LP20170904: 0.077 ng/l, limit of quantification for LP20170904: 0.19 ng/l
8Perfluoropentanoic acidPFPeAng/lJoerss, HannaSolid-phase extraction (SPE) and cleanup, coupled liquid chromatography tandem mass spectrometry (LC-MS/MS)measured in water column, limit of detection for LP20170606: 0.042 ng/l, limit of quantification for LP20170606: 0.12 ng/l, limit of detection for LP20170904: 0.051 ng/l, limit of quantification for LP20170904: 0.14 ng/l
9Perfluorohexanoic acidPFHxAng/lJoerss, HannaSolid-phase extraction (SPE) and cleanup, coupled liquid chromatography tandem mass spectrometry (LC-MS/MS)measured in water column, limit of detection for LP20170606: 0.055 ng/l, limit of quantification for LP20170606: 0.095 ng/l, limit of detection for LP20170904: 0.043 ng/l, limit of quantification for LP20170904: 0.14 ng/l
10Perfluoroheptanoic acidPFHpAng/lJoerss, HannaSolid-phase extraction (SPE) and cleanup, coupled liquid chromatography tandem mass spectrometry (LC-MS/MS)measured in water column, limit of detection for LP20170606: 0.024 ng/l, limit of quantification for LP20170606: 0.079 ng/l, limit of detection for LP20170904: 0.039 ng/l, limit of quantification for LP20170904: 0.13 ng/l
11Perfluorooctanoic acidPFOAng/lJoerss, HannaSolid-phase extraction (SPE) and cleanup, coupled liquid chromatography tandem mass spectrometry (LC-MS/MS)measured in water column, limit of detection for LP20170606: 0.11 ng/l, limit of quantification for LP20170606: 0.22 ng/l, limit of detection for LP20170904: 0.048 ng/l, limit of quantification for LP20170904: 0.095 ng/l
12Perfluorononanoic acidPFNAng/lJoerss, HannaSolid-phase extraction (SPE) and cleanup, coupled liquid chromatography tandem mass spectrometry (LC-MS/MS)measured in water column, limit of detection for LP20170606: 0.063 ng/l, limit of quantification for LP20170606: 0.14 ng/l, limit of detection for LP20170904: 0.033 ng/l, limit of quantification for LP20170904: 0.063 ng/l
13Perfluorodecanoic acidPFDAng/lJoerss, HannaSolid-phase extraction (SPE) and cleanup, coupled liquid chromatography tandem mass spectrometry (LC-MS/MS)measured in water column, limit of detection for LP20170606: 0.041 ng/l, limit of quantification for LP20170606: 0.087 ng/l, limit of detection for LP20170904: 0.024 ng/l, limit of quantification for LP20170904: 0.046 ng/l
14Perfluoroundecanoic acidPFUnDAng/lJoerss, HannaSolid-phase extraction (SPE) and cleanup, coupled liquid chromatography tandem mass spectrometry (LC-MS/MS)measured in water column, limit of detection for LP20170606: 0.028 ng/l, limit of quantification for LP20170606: 0.063 ng/l, limit of detection for LP20170904: 0.024 ng/l, limit of quantification for LP20170904: 0.05 ng/l
15Perfluorododecanoic acidPFDoDAng/lJoerss, HannaSolid-phase extraction (SPE) and cleanup, coupled liquid chromatography tandem mass spectrometry (LC-MS/MS)measured in water column, limit of detection: 0.017 ng/l, limit of quantification: 0.057 ng/l
16Perfluorotridecanoic acidPFTrDAng/lJoerss, HannaSolid-phase extraction (SPE) and cleanup, coupled liquid chromatography tandem mass spectrometry (LC-MS/MS)measured in water column, limit of detection: 0.0046 ng/l, limit of quantification: 0.015 ng/l
17Perfluorotetradecanoic acidPFTeDAng/lJoerss, HannaSolid-phase extraction (SPE) and cleanup, coupled liquid chromatography tandem mass spectrometry (LC-MS/MS)measured in water column, limit of detection: 0.0088 ng/l, limit of quantification: 0.029 ng/l
18Perfluorobutane sulfonic acidPFBSng/lJoerss, HannaSolid-phase extraction (SPE) and cleanup, coupled liquid chromatography tandem mass spectrometry (LC-MS/MS)measured in water column, limit of detection for LP20170606: 0.045 ng/l, limit of quantification for LP20170606: 0.15 ng/l, limit of detection for LP20170904: 0.052 ng/l, limit of quantification for LP20170904: 0.17 ng/l
19Perfluorohexane sulfonic acidPFHxSng/lJoerss, HannaSolid-phase extraction (SPE) and cleanup, coupled liquid chromatography tandem mass spectrometry (LC-MS/MS)measured in water column, limit of detection for LP20170606: 0.073 ng/l, limit of quantification for LP20170606: 0.24 ng/l, limit of detection for LP20170904: 0.1 ng/l, limit of quantification for LP20170904: 0.34 ng/l
20Perfluoroheptane sulfonic acidPFHpSng/lJoerss, HannaSolid-phase extraction (SPE) and cleanup, coupled liquid chromatography tandem mass spectrometry (LC-MS/MS)measured in water column, limit of detection: 0.027 ng/l, limit of quantification: 0.09 ng/l
21Perfluorooctane sulfonic acidPFOSng/lJoerss, HannaSolid-phase extraction (SPE) and cleanup, coupled liquid chromatography tandem mass spectrometry (LC-MS/MS)measured in water column, limit of detection for LP20170606: 0.0057 ng/l, limit of quantification for LP20170606: 0.019 ng/l, limit of detection for LP20170904: 0.015 ng/l, limit of quantification for LP20170904: 0.036 ng/l
22Perfluorodecane sulfonic acidPFDSng/lJoerss, HannaSolid-phase extraction (SPE) and cleanup, coupled liquid chromatography tandem mass spectrometry (LC-MS/MS)measured in water column, limit of detection: 0.032 ng/l, limit of quantification: 0.093 ng/l
23Perfluoro-4-ethylcyclohexane sulfonic acidPFECHSng/lJoerss, HannaSolid-phase extraction (SPE) and cleanup, coupled liquid chromatography tandem mass spectrometry (LC-MS/MS)measured in water column, limit of detection for LP20170606: 0.043 ng/l, limit of quantification for LP20170606: 0.14 ng/l, limit of detection for LP20170904: 0.038 ng/l, limit of quantification for LP20170904: 0.13 ng/l
242,2,3-trifluoro-3-[1,1,2,2,3,3-hexafluoro-3-(trifluoromethoxy)propoxy]propanoic acidDONAng/lJoerss, HannaSolid-phase extraction (SPE) and cleanup, coupled liquid chromatography tandem mass spectrometry (LC-MS/MS)measured in water column, limit of detection: 0.0075 ng/l, limit of quantification: 0.025 ng/l
252,3,3,3-tetrafluoro-2-(1,1,2,2,3,3,3,-heptafluoropropoxy)-propanoic acidHFPO-DAng/lJoerss, HannaSolid-phase extraction (SPE) and cleanup, coupled liquid chromatography tandem mass spectrometry (LC-MS/MS)measured in water column, limit of detection for LP20170606: 0.044 ng/l, limit of quantification for LP20170606: 0.15 ng/l, limit of detection for LP20170904: 0.018 ng/l, limit of quantification for LP20170904: 0.059 ng/l
26Hexafluoropropylene oxide trimer acidHFPO-TrAng/lJoerss, HannaSolid-phase extraction (SPE) and cleanup, coupled liquid chromatography tandem mass spectrometry (LC-MS/MS)measured in water column, limit of detection: 0.044 ng/l, limit of quantification: 0.15 ng/l
27Hexafluoropropylene oxide tetramer acidHFPO-TeAng/lJoerss, HannaSolid-phase extraction (SPE) and cleanup, coupled liquid chromatography tandem mass spectrometry (LC-MS/MS)measured in water column, limit of detection: 0.075 ng/l, limit of quantification: 0.25 ng/l
289-chlorohexadecafluoro-3-oxanonane-1-sulfonic acid9Cl-PF3ONSng/lJoerss, HannaSolid-phase extraction (SPE) and cleanup, coupled liquid chromatography tandem mass spectrometry (LC-MS/MS)measured in water column, limit of detection: 0.0069 ng/l, limit of quantification: 0.023 ng/l
29Bis(perfluorohexyl)phosphinic acid6:6PFPiAng/lJoerss, HannaSolid-phase extraction (SPE) and cleanup, coupled liquid chromatography tandem mass spectrometry (LC-MS/MS)measured in water column, limit of detection: 0.0049 ng/l, limit of quantification: 0.016 ng/l
30Perfluorohexylperfluorooctylphosphinic acid6:8PFPiAng/lJoerss, HannaSolid-phase extraction (SPE) and cleanup, coupled liquid chromatography tandem mass spectrometry (LC-MS/MS)measured in water column, limit of detection: 0.0087 ng/l, limit of quantification: 0.029 ng/l
31Perfluorooctane sulfonamideFOSAng/lJoerss, HannaSolid-phase extraction (SPE) and cleanup, coupled liquid chromatography tandem mass spectrometry (LC-MS/MS)measured in water column, limit of detection for LP20170606: 0.0036 ng/l, limit of quantification for LP20170606: 0.012 ng/l, limit of detection for LP20170904: 0.0022 ng/l, limit of quantification for LP20170904: 0.0074 ng/l
324:2 fluorotelomer sulfonic acid4:2FTSAng/lJoerss, HannaSolid-phase extraction (SPE) and cleanup, coupled liquid chromatography tandem mass spectrometry (LC-MS/MS)measured in water column, limit of detection: 0.03 ng/l, limit of quantification: 0.1 ng/l
336:2 fluorotelomer sulfonic acid6:2 FTSAng/lJoerss, HannaSolid-phase extraction (SPE) and cleanup, coupled liquid chromatography tandem mass spectrometry (LC-MS/MS)measured in water column, limit of detection for LP20170606: 0.061 ng/l, limit of quantification for LP20170606: 0.15 ng/l, limit of detection for LP20170904: 0.28 ng/l, limit of quantification for LP20170904: 0.48 ng/l
348:2 fluorotelomer sulfonic acid8:2FTSAng/lJoerss, HannaSolid-phase extraction (SPE) and cleanup, coupled liquid chromatography tandem mass spectrometry (LC-MS/MS)measured in water column, limit of detection: 0.036 ng/l, limit of quantification: 0.12 ng/l
3511-chloroeicosafluoro-3-oxaundecane-1-sulfonic acid11Cl-PF3OUdSng/lJoerss, HannaSolid-phase extraction (SPE) and cleanup, coupled liquid chromatography tandem mass spectrometry (LC-MS/MS)measured in water column, limit of detection: 0.0068 ng/l, limit of quantification: 0.023 ng/l
Size:
2639 data points

Download Data

Download dataset as tab-delimited text — use the following character encoding:

View dataset as HTML (shows only first 2000 rows)