Joerss, Hanna; Apel, Christina; Ebinghaus, Ralf (2021): Per- and polyfluoroalkyl substances (PFASs) in surface water of the North and Baltic Seas in 2016/2017 [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.927756
Always quote citation above when using data! You can download the citation in several formats below.
Published: 2021-02-10 • DOI registered: 2021-04-27
Related to:
Joerss, Hanna; Apel, Christina; Ebinghaus, Ralf (2019): Emerging per- and polyfluoroalkyl substances (PFASs) in surface water and sediment of the North and Baltic Seas. Science of the Total Environment, 686, 360-369, https://doi.org/10.1016/j.scitotenv.2019.05.363
Project(s):
Coverage:
Median Latitude: 54.107058 * Median Longitude: 10.143501 * South-bound Latitude: 53.448000 * West-bound Longitude: 7.126333 * North-bound Latitude: 54.887450 * East-bound Longitude: 14.543650
Date/Time Start: 2017-06-06T06:06:00 * Date/Time End: 2017-09-10T15:10:00
Minimum DEPTH, water: 0 m * Maximum DEPTH, water: 0 m
Event(s):
LP20170606_1WS * Latitude: 53.448000 * Longitude: 10.089000 * Date/Time: 2017-06-06T06:06:00 * Campaign: LP20170606 * Basis: Ludwig Prandtl * Method/Device: Water sample (WS)
LP20170606_2WS * Latitude: 53.537633 * Longitude: 10.002850 * Date/Time: 2017-06-06T08:28:10 * Campaign: LP20170606 * Basis: Ludwig Prandtl * Method/Device: Water sample (WS)
LP20170606_5WS * Latitude: 53.547167 * Longitude: 9.877383 * Date/Time: 2017-06-06T09:26:42 * Campaign: LP20170606 * Basis: Ludwig Prandtl * Method/Device: Water sample (WS)
Parameter(s):
| # | Name | Short Name | Unit | Principal Investigator | Method/Device | Comment |
|---|---|---|---|---|---|---|
| 1 | Event label | Event | Joerss, Hanna | |||
| 2 | Campaign of event | Campaign | Joerss, Hanna | |||
| 3 | Latitude of event | Latitude | Joerss, Hanna | |||
| 4 | Longitude of event | Longitude | Joerss, Hanna | |||
| 5 | Date/Time of event | Date/Time | Joerss, Hanna | |||
| 6 | DEPTH, water | Depth water | m | Joerss, Hanna | Geocode | |
| 7 | Perfluorobutanoic acid | PFBA | ng/l | Joerss, Hanna | Solid-phase extraction (SPE) and cleanup, coupled liquid chromatography tandem mass spectrometry (LC-MS/MS) | measured in water column, limit of detection for LP20170606: 0.16 ng/l, limit of quantification for LP20170606: 0.35 ng/l, limit of detection for LP20170904: 0.077 ng/l, limit of quantification for LP20170904: 0.19 ng/l |
| 8 | Perfluoropentanoic acid | PFPeA | ng/l | Joerss, Hanna | Solid-phase extraction (SPE) and cleanup, coupled liquid chromatography tandem mass spectrometry (LC-MS/MS) | measured in water column, limit of detection for LP20170606: 0.042 ng/l, limit of quantification for LP20170606: 0.12 ng/l, limit of detection for LP20170904: 0.051 ng/l, limit of quantification for LP20170904: 0.14 ng/l |
| 9 | Perfluorohexanoic acid | PFHxA | ng/l | Joerss, Hanna | Solid-phase extraction (SPE) and cleanup, coupled liquid chromatography tandem mass spectrometry (LC-MS/MS) | measured in water column, limit of detection for LP20170606: 0.055 ng/l, limit of quantification for LP20170606: 0.095 ng/l, limit of detection for LP20170904: 0.043 ng/l, limit of quantification for LP20170904: 0.14 ng/l |
| 10 | Perfluoroheptanoic acid | PFHpA | ng/l | Joerss, Hanna | Solid-phase extraction (SPE) and cleanup, coupled liquid chromatography tandem mass spectrometry (LC-MS/MS) | measured in water column, limit of detection for LP20170606: 0.024 ng/l, limit of quantification for LP20170606: 0.079 ng/l, limit of detection for LP20170904: 0.039 ng/l, limit of quantification for LP20170904: 0.13 ng/l |
| 11 | Perfluorooctanoic acid | PFOA | ng/l | Joerss, Hanna | Solid-phase extraction (SPE) and cleanup, coupled liquid chromatography tandem mass spectrometry (LC-MS/MS) | measured in water column, limit of detection for LP20170606: 0.11 ng/l, limit of quantification for LP20170606: 0.22 ng/l, limit of detection for LP20170904: 0.048 ng/l, limit of quantification for LP20170904: 0.095 ng/l |
| 12 | Perfluorononanoic acid | PFNA | ng/l | Joerss, Hanna | Solid-phase extraction (SPE) and cleanup, coupled liquid chromatography tandem mass spectrometry (LC-MS/MS) | measured in water column, limit of detection for LP20170606: 0.063 ng/l, limit of quantification for LP20170606: 0.14 ng/l, limit of detection for LP20170904: 0.033 ng/l, limit of quantification for LP20170904: 0.063 ng/l |
| 13 | Perfluorodecanoic acid | PFDA | ng/l | Joerss, Hanna | Solid-phase extraction (SPE) and cleanup, coupled liquid chromatography tandem mass spectrometry (LC-MS/MS) | measured in water column, limit of detection for LP20170606: 0.041 ng/l, limit of quantification for LP20170606: 0.087 ng/l, limit of detection for LP20170904: 0.024 ng/l, limit of quantification for LP20170904: 0.046 ng/l |
| 14 | Perfluoroundecanoic acid | PFUnDA | ng/l | Joerss, Hanna | Solid-phase extraction (SPE) and cleanup, coupled liquid chromatography tandem mass spectrometry (LC-MS/MS) | measured in water column, limit of detection for LP20170606: 0.028 ng/l, limit of quantification for LP20170606: 0.063 ng/l, limit of detection for LP20170904: 0.024 ng/l, limit of quantification for LP20170904: 0.05 ng/l |
| 15 | Perfluorododecanoic acid | PFDoDA | ng/l | Joerss, Hanna | Solid-phase extraction (SPE) and cleanup, coupled liquid chromatography tandem mass spectrometry (LC-MS/MS) | measured in water column, limit of detection: 0.017 ng/l, limit of quantification: 0.057 ng/l |
| 16 | Perfluorotridecanoic acid | PFTrDA | ng/l | Joerss, Hanna | Solid-phase extraction (SPE) and cleanup, coupled liquid chromatography tandem mass spectrometry (LC-MS/MS) | measured in water column, limit of detection: 0.0046 ng/l, limit of quantification: 0.015 ng/l |
| 17 | Perfluorotetradecanoic acid | PFTeDA | ng/l | Joerss, Hanna | Solid-phase extraction (SPE) and cleanup, coupled liquid chromatography tandem mass spectrometry (LC-MS/MS) | measured in water column, limit of detection: 0.0088 ng/l, limit of quantification: 0.029 ng/l |
| 18 | Perfluorobutane sulfonic acid | PFBS | ng/l | Joerss, Hanna | Solid-phase extraction (SPE) and cleanup, coupled liquid chromatography tandem mass spectrometry (LC-MS/MS) | measured in water column, limit of detection for LP20170606: 0.045 ng/l, limit of quantification for LP20170606: 0.15 ng/l, limit of detection for LP20170904: 0.052 ng/l, limit of quantification for LP20170904: 0.17 ng/l |
| 19 | Perfluorohexane sulfonic acid | PFHxS | ng/l | Joerss, Hanna | Solid-phase extraction (SPE) and cleanup, coupled liquid chromatography tandem mass spectrometry (LC-MS/MS) | measured in water column, limit of detection for LP20170606: 0.073 ng/l, limit of quantification for LP20170606: 0.24 ng/l, limit of detection for LP20170904: 0.1 ng/l, limit of quantification for LP20170904: 0.34 ng/l |
| 20 | Perfluoroheptane sulfonic acid | PFHpS | ng/l | Joerss, Hanna | Solid-phase extraction (SPE) and cleanup, coupled liquid chromatography tandem mass spectrometry (LC-MS/MS) | measured in water column, limit of detection: 0.027 ng/l, limit of quantification: 0.09 ng/l |
| 21 | Perfluorooctane sulfonic acid | PFOS | ng/l | Joerss, Hanna | Solid-phase extraction (SPE) and cleanup, coupled liquid chromatography tandem mass spectrometry (LC-MS/MS) | measured in water column, limit of detection for LP20170606: 0.0057 ng/l, limit of quantification for LP20170606: 0.019 ng/l, limit of detection for LP20170904: 0.015 ng/l, limit of quantification for LP20170904: 0.036 ng/l |
| 22 | Perfluorodecane sulfonic acid | PFDS | ng/l | Joerss, Hanna | Solid-phase extraction (SPE) and cleanup, coupled liquid chromatography tandem mass spectrometry (LC-MS/MS) | measured in water column, limit of detection: 0.032 ng/l, limit of quantification: 0.093 ng/l |
| 23 | Perfluoro-4-ethylcyclohexane sulfonic acid | PFECHS | ng/l | Joerss, Hanna | Solid-phase extraction (SPE) and cleanup, coupled liquid chromatography tandem mass spectrometry (LC-MS/MS) | measured in water column, limit of detection for LP20170606: 0.043 ng/l, limit of quantification for LP20170606: 0.14 ng/l, limit of detection for LP20170904: 0.038 ng/l, limit of quantification for LP20170904: 0.13 ng/l |
| 24 | 2,2,3-trifluoro-3-[1,1,2,2,3,3-hexafluoro-3-(trifluoromethoxy)propoxy]propanoic acid | DONA | ng/l | Joerss, Hanna | Solid-phase extraction (SPE) and cleanup, coupled liquid chromatography tandem mass spectrometry (LC-MS/MS) | measured in water column, limit of detection: 0.0075 ng/l, limit of quantification: 0.025 ng/l |
| 25 | 2,3,3,3-tetrafluoro-2-(1,1,2,2,3,3,3,-heptafluoropropoxy)-propanoic acid | HFPO-DA | ng/l | Joerss, Hanna | Solid-phase extraction (SPE) and cleanup, coupled liquid chromatography tandem mass spectrometry (LC-MS/MS) | measured in water column, limit of detection for LP20170606: 0.044 ng/l, limit of quantification for LP20170606: 0.15 ng/l, limit of detection for LP20170904: 0.018 ng/l, limit of quantification for LP20170904: 0.059 ng/l |
| 26 | Hexafluoropropylene oxide trimer acid | HFPO-TrA | ng/l | Joerss, Hanna | Solid-phase extraction (SPE) and cleanup, coupled liquid chromatography tandem mass spectrometry (LC-MS/MS) | measured in water column, limit of detection: 0.044 ng/l, limit of quantification: 0.15 ng/l |
| 27 | Hexafluoropropylene oxide tetramer acid | HFPO-TeA | ng/l | Joerss, Hanna | Solid-phase extraction (SPE) and cleanup, coupled liquid chromatography tandem mass spectrometry (LC-MS/MS) | measured in water column, limit of detection: 0.075 ng/l, limit of quantification: 0.25 ng/l |
| 28 | 9-chlorohexadecafluoro-3-oxanonane-1-sulfonic acid | 9Cl-PF3ONS | ng/l | Joerss, Hanna | Solid-phase extraction (SPE) and cleanup, coupled liquid chromatography tandem mass spectrometry (LC-MS/MS) | measured in water column, limit of detection: 0.0069 ng/l, limit of quantification: 0.023 ng/l |
| 29 | Bis(perfluorohexyl)phosphinic acid | 6:6PFPiA | ng/l | Joerss, Hanna | Solid-phase extraction (SPE) and cleanup, coupled liquid chromatography tandem mass spectrometry (LC-MS/MS) | measured in water column, limit of detection: 0.0049 ng/l, limit of quantification: 0.016 ng/l |
| 30 | Perfluorohexylperfluorooctylphosphinic acid | 6:8PFPiA | ng/l | Joerss, Hanna | Solid-phase extraction (SPE) and cleanup, coupled liquid chromatography tandem mass spectrometry (LC-MS/MS) | measured in water column, limit of detection: 0.0087 ng/l, limit of quantification: 0.029 ng/l |
| 31 | Perfluorooctane sulfonamide | FOSA | ng/l | Joerss, Hanna | Solid-phase extraction (SPE) and cleanup, coupled liquid chromatography tandem mass spectrometry (LC-MS/MS) | measured in water column, limit of detection for LP20170606: 0.0036 ng/l, limit of quantification for LP20170606: 0.012 ng/l, limit of detection for LP20170904: 0.0022 ng/l, limit of quantification for LP20170904: 0.0074 ng/l |
| 32 | 4:2 fluorotelomer sulfonic acid | 4:2FTSA | ng/l | Joerss, Hanna | Solid-phase extraction (SPE) and cleanup, coupled liquid chromatography tandem mass spectrometry (LC-MS/MS) | measured in water column, limit of detection: 0.03 ng/l, limit of quantification: 0.1 ng/l |
| 33 | 6:2 fluorotelomer sulfonic acid | 6:2 FTSA | ng/l | Joerss, Hanna | Solid-phase extraction (SPE) and cleanup, coupled liquid chromatography tandem mass spectrometry (LC-MS/MS) | measured in water column, limit of detection for LP20170606: 0.061 ng/l, limit of quantification for LP20170606: 0.15 ng/l, limit of detection for LP20170904: 0.28 ng/l, limit of quantification for LP20170904: 0.48 ng/l |
| 34 | 8:2 fluorotelomer sulfonic acid | 8:2FTSA | ng/l | Joerss, Hanna | Solid-phase extraction (SPE) and cleanup, coupled liquid chromatography tandem mass spectrometry (LC-MS/MS) | measured in water column, limit of detection: 0.036 ng/l, limit of quantification: 0.12 ng/l |
| 35 | 11-chloroeicosafluoro-3-oxaundecane-1-sulfonic acid | 11Cl-PF3OUdS | ng/l | Joerss, Hanna | Solid-phase extraction (SPE) and cleanup, coupled liquid chromatography tandem mass spectrometry (LC-MS/MS) | measured in water column, limit of detection: 0.0068 ng/l, limit of quantification: 0.023 ng/l |
License:
Creative Commons Attribution 4.0 International (CC-BY-4.0)
Size:
2639 data points
Download Data
View dataset as HTML (shows only first 2000 rows)