Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

Mouat, Asher P; Kaiser, Jennifer; Paton-Walsh, Clare; Ramirez-Gamboa, Jhonathan; Naylor, Travis A; Simmons, Jack B (2021): Volatile organic compound measurements at Cataract Scout Park, Australia, taken during the COALA-2020 campaign [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.927277

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Abstract:
Measurements of volatile organic compounds (VOCs) were collected using an Ionicon 4000 Proton Transfer Reaction Time of Flight Mass Spectrometer (PTR-ToF-MS). Measurements were taken at Cataract Scout Park, Appin, N.S.W. (34°14'42.29"S 150°49'24.97"E) from an inlet 10 m above ground level as part of the Characterizing Organics and Aerosol Loading over Australia (COALA-2020) campaign. The campaign ran from mid-January to mid-March, 2020, with the instrument running from early February. Sample air was drawn down a 20 m PTFE inlet line with a bypass pump (flow rate 1.5 - 3 L min-1). Calibration occurred in situ using standard cylinders for the compounds reported below. Calibration uncertainty is ±20%. Additional compounds may be available on request. Measurements were processed using the Ionicon PTR-MS Viewer software. Measurements from February 2 - February 7 have been corrected to account for an identified inlet leak. A flat subtraction was applied, and resulting compound offsets are provided in the parameter comments. Data from February 7 – February 16 have been removed due to identified leak requiring greater corrections.
Keyword(s):
Australia; Biogenic VOC; biomass burning; COALA-2020; volatile organic compounds
Related to:
Griffith, David W T; Paton-Walsh, Clare; Naylor, Travis A; Kettlewell, Graham; Ramirez-Gamboa, Jhonathan; Simmons, Jack B; Carter, Alex; Dang, Quang Phuc; Webb, Alayna (2021): Greenhouse gases measurements at Cataract Scout Park, Australia, taken during the COALA-2020 campaign. PANGAEA, https://doi.org/10.1594/PANGAEA.927313
Griffiths, Alan D; Naylor, Travis A; Paton-Walsh, Clare; Carter, Alex (2021): Wind speed and direction measurements at Cataract Scout Park, Australia, taken during the COALA-2020 campaign. PANGAEA, https://doi.org/10.1594/PANGAEA.928929
Griffiths, Alan D; Williams, Alastair G; Chambers, Scott D; Naylor, Travis A; Simmons, Jack B; Ramirez-Gamboa, Jhonathan; Webb, Alayna; Dang, Quang Phuc; Carter, Alex; Paton-Walsh, Clare (2021): Radon-222 measurements at Cataract Scout Park, Australia, taken during the COALA-2020 campaign. PANGAEA, https://doi.org/10.1594/PANGAEA.928372
Humphries, Ruhi S; Keywood, Melita D; Paton-Walsh, Clare; Naylor, Travis A; Simmons, Jack B; Ramirez-Gamboa, Jhonathan; Carter, Alex; Dang, Quang Phuc; Webb, Alayna (2021): Aerosol size distribution measurements at Cataract Scout Park, Australia, taken during the COALA-2020 campaign. PANGAEA, https://doi.org/10.1594/PANGAEA.928853
Humphries, Ruhi S; Keywood, Melita D; Paton-Walsh, Clare; Naylor, Travis A; Simmons, Jack B; Ramirez-Gamboa, Jhonathan; Carter, Alex; Dang, Quang Phuc; Webb, Alayna (2021): Cloud condensation nuclei (CCN) measurements at Cataract Scout Park, Australia, taken during the COALA-2020 campaign. PANGAEA, https://doi.org/10.1594/PANGAEA.928925
Keywood, Melita D; Humphries, Ruhi S; Paton-Walsh, Clare; Naylor, Travis A; Ramirez-Gamboa, Jhonathan; Simmons, Jack B; Carter, Alex; Dang, Quang Phuc; Webb, Alayna (2020): Condensation nuclei >3 nm (CN3) measurements at Cataract Scout Park, Australia, taken during the COALA-2020 campaign. PANGAEA, https://doi.org/10.1594/PANGAEA.925555
Keywood, Melita D; Humphries, Ruhi S; Paton-Walsh, Clare; Naylor, Travis A; Ramirez-Gamboa, Jhonathan; Simmons, Jack B; Carter, Alex; Dang, Quang Phuc; Webb, Alayna (2021): Black carbon aerosol measurements at Cataract Scout Park, Australia, taken during the COALA-2020 campaign. PANGAEA, https://doi.org/10.1594/PANGAEA.927544
Mouat, Asher P; Kaiser, Jennifer; Paton-Walsh, Clare; Ramirez-Gamboa, Jhonathan; Naylor, Travis A; Simmons, Jack B (in prep.): Observations of long-lived volatile organic compounds from the 2019-2020 Australian wildfires during the COALA campaign.
Naylor, Travis A; Paton-Walsh, Clare; Ramirez-Gamboa, Jhonathan; Carter, Alex; Webb, Alayna; Dang, Quang Phuc; Simmons, Jack B; Griffiths, Alan D (2021): Photosynthetically active radiation measurements at Cataract Scout Park, Australia, taken during the COALA-2020 campaign. PANGAEA, https://doi.org/10.1594/PANGAEA.928051
Simmons, Jack B; Paton-Walsh, Clare; Mouat, Asher P; Kaiser, Jennifer; Humphries, Ruhi S; Keywood, Melita D; Griffith, David W T; Sutresna, Adhitya; Naylor, Travis A; Ramirez-Gamboa, Jhonathan (accepted): Bushfire smoke plume composition and toxicological assessment from the 2019–2020 Australian Black Summer. Air Quality, Atmosphere & Health, https://doi.org/10.1007/s11869-022-01237-5
Coverage:
Latitude: -34.245081 * Longitude: 150.823603
Date/Time Start: 2020-02-02T01:34:00 * Date/Time End: 2020-03-19T05:15:00
Minimum HEIGHT above ground: 10.00 m * Maximum HEIGHT above ground: 10.00 m
Event(s):
Cataract_scout_park * Latitude: -34.245081 * Longitude: 150.823603 * Date/Time Start: 2020-01-18T00:00:00 * Date/Time End: 2020-03-19T00:00:00 * Location: Appin, Australia * Campaign: COALA-2020 (COALA-2020) * Method/Device: Multiple investigations (MULT)
Comment:
Empty cells = nd
COALA-2020 was funded by Australia's National Environmental Science Program through the Clean Air and Urban Landscapes hub.
Instrument precision estimated from calibration data.
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
1DATE/TIMEDate/TimePaton-Walsh, ClareGeocode
2HEIGHT above groundHeightmPaton-Walsh, ClareGeocode
3MethanolCH4OppbvPaton-Walsh, ClareProton Transfer Reaction Time of Flight Mass Spectrometer, Ionicon 4000 (PTR-ToF-MS, Ionicon 4000)Calibrated from methanol in calibration standard, correction: 1300 pptv
4PrecisionPrecpptvPaton-Walsh, ClareProton Transfer Reaction Time of Flight Mass Spectrometer, Ionicon 4000 (PTR-ToF-MS, Ionicon 4000)Instrument precision for methanol measurements
5AcetonitrileC2H3NppbvPaton-Walsh, ClareProton Transfer Reaction Time of Flight Mass Spectrometer, Ionicon 4000 (PTR-ToF-MS, Ionicon 4000)Calibrated from acetonitrile in calibration standard, correction: 0 pptv
6PrecisionPrecpptvPaton-Walsh, ClareProton Transfer Reaction Time of Flight Mass Spectrometer, Ionicon 4000 (PTR-ToF-MS, Ionicon 4000)Instrument precision for acetonitrile measurements
7AcetaldehydeC2H4OppbvPaton-Walsh, ClareProton Transfer Reaction Time of Flight Mass Spectrometer, Ionicon 4000 (PTR-ToF-MS, Ionicon 4000)Calibrated from acetaldehyde in calibration standard, correction: 200 pptv
8PrecisionPrecpptvPaton-Walsh, ClareProton Transfer Reaction Time of Flight Mass Spectrometer, Ionicon 4000 (PTR-ToF-MS, Ionicon 4000)Instrument precision for acetaldehyde measurements
9Prop-2-enalAcrolein (C3H4O)ppbvPaton-Walsh, ClareProton Transfer Reaction Time of Flight Mass Spectrometer, Ionicon 4000 (PTR-ToF-MS, Ionicon 4000)Calibrated from acrolein in calibration standard, correction: 0 pptv
10PrecisionPrecpptvPaton-Walsh, ClareProton Transfer Reaction Time of Flight Mass Spectrometer, Ionicon 4000 (PTR-ToF-MS, Ionicon 4000)Instrument precision for prop-2-enal measurements
11AcetoneC3H6OppbvPaton-Walsh, ClareProton Transfer Reaction Time of Flight Mass Spectrometer, Ionicon 4000 (PTR-ToF-MS, Ionicon 4000)Calibrated from acetone in calibration standard, correction: 100 pptv
12PrecisionPrecpptvPaton-Walsh, ClareProton Transfer Reaction Time of Flight Mass Spectrometer, Ionicon 4000 (PTR-ToF-MS, Ionicon 4000)Instrument precision for acetone measurements
13IsopreneC5H8pptvPaton-Walsh, ClareProton Transfer Reaction Time of Flight Mass Spectrometer, Ionicon 4000 (PTR-ToF-MS, Ionicon 4000)Calibrated from isoprene in calibration standard, correction: 150 pptv
14PrecisionPrecpptvPaton-Walsh, ClareProton Transfer Reaction Time of Flight Mass Spectrometer, Ionicon 4000 (PTR-ToF-MS, Ionicon 4000)Instrument precision for isoprene measurements
15Methacrolein + methyl vinyl ketoneMACR+MVKppbvPaton-Walsh, ClareProton Transfer Reaction Time of Flight Mass Spectrometer, Ionicon 4000 (PTR-ToF-MS, Ionicon 4000)Calibrated from weighted average of methacrolein and methyl vinyl ketone in calibration standard, correction: 0 pptv
16PrecisionPrecpptvPaton-Walsh, ClareProton Transfer Reaction Time of Flight Mass Spectrometer, Ionicon 4000 (PTR-ToF-MS, Ionicon 4000)Instrument precision for methacrolein plus methyl vinyl ketone measurements
17Butan-2-oneMethyl ethyl ketone (C4H8O)ppbvPaton-Walsh, ClareProton Transfer Reaction Time of Flight Mass Spectrometer, Ionicon 4000 (PTR-ToF-MS, Ionicon 4000)Calibrated from methyl ethyl ketone in calibration standard, correction: 0 pptv
18PrecisionPrecpptvPaton-Walsh, ClareProton Transfer Reaction Time of Flight Mass Spectrometer, Ionicon 4000 (PTR-ToF-MS, Ionicon 4000)Instrument precision for butan-2-one measurements
19BenzeneC6H6pptvPaton-Walsh, ClareProton Transfer Reaction Time of Flight Mass Spectrometer, Ionicon 4000 (PTR-ToF-MS, Ionicon 4000)Calibrated from benzene in calibration standard, correction: 0 pptv
20PrecisionPrecpptvPaton-Walsh, ClareProton Transfer Reaction Time of Flight Mass Spectrometer, Ionicon 4000 (PTR-ToF-MS, Ionicon 4000)Instrument precision for benzene measurements
21TolueneC6H5CH3ppbvPaton-Walsh, ClareProton Transfer Reaction Time of Flight Mass Spectrometer, Ionicon 4000 (PTR-ToF-MS, Ionicon 4000)Calibrated from toluene in calibration standard, correction: 0 pptv
22PrecisionPrecpptvPaton-Walsh, ClareProton Transfer Reaction Time of Flight Mass Spectrometer, Ionicon 4000 (PTR-ToF-MS, Ionicon 4000)Instrument precision for toluene measurements
23Sum C8H10C8H10ppbvPaton-Walsh, ClareProton Transfer Reaction Time of Flight Mass Spectrometer, Ionicon 4000 (PTR-ToF-MS, Ionicon 4000)Calibrated from xylene in CSIRO-provided calibration standard, correction: 100 pptv
24PrecisionPrecpptvPaton-Walsh, ClareProton Transfer Reaction Time of Flight Mass Spectrometer, Ionicon 4000 (PTR-ToF-MS, Ionicon 4000)Instrument precision for sum of C8H10 measurements
25Sum C9H12C9H12ppbvPaton-Walsh, ClareProton Transfer Reaction Time of Flight Mass Spectrometer, Ionicon 4000 (PTR-ToF-MS, Ionicon 4000)Calibrated from trimethylbenzene in CSIRO-provided calibration standard, correction: 0 pptv
26PrecisionPrecpptvPaton-Walsh, ClareProton Transfer Reaction Time of Flight Mass Spectrometer, Ionicon 4000 (PTR-ToF-MS, Ionicon 4000)Instrument precision for sum of C9H12 measurements
27MonoterpenesMonoterpenesppbvPaton-Walsh, ClareProton Transfer Reaction Time of Flight Mass Spectrometer, Ionicon 4000 (PTR-ToF-MS, Ionicon 4000)Calibrated from standards using a-pinene and cineole, correction: 0 pptv
28PrecisionPrecpptvPaton-Walsh, ClareProton Transfer Reaction Time of Flight Mass Spectrometer, Ionicon 4000 (PTR-ToF-MS, Ionicon 4000)Instrument precision for monoterpene measurements
Status:
Curation Level: Enhanced curation (CurationLevelC)
Size:
885045 data points

Download Data

Download dataset as tab-delimited text — use the following character encoding:

View dataset as HTML (shows only first 2000 rows)