Mouat, Asher P; Kaiser, Jennifer; Paton-Walsh, Clare; Ramirez-Gamboa, Jhonathan; Naylor, Travis A; Simmons, Jack B (2021): Volatile organic compound measurements at Cataract Scout Park, Australia, taken during the COALA-2020 campaign [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.927277
Always quote citation above when using data! You can download the citation in several formats below.
Abstract:
Measurements of volatile organic compounds (VOCs) were collected using an Ionicon 4000 Proton Transfer Reaction Time of Flight Mass Spectrometer (PTR-ToF-MS). Measurements were taken at Cataract Scout Park, Appin, N.S.W. (34°14'42.29"S 150°49'24.97"E) from an inlet 10 m above ground level as part of the Characterizing Organics and Aerosol Loading over Australia (COALA-2020) campaign. The campaign ran from mid-January to mid-March, 2020, with the instrument running from early February. Sample air was drawn down a 20 m PTFE inlet line with a bypass pump (flow rate 1.5 - 3 L min-1). Calibration occurred in situ using standard cylinders for the compounds reported below. Calibration uncertainty is ±20%. Additional compounds may be available on request. Measurements were processed using the Ionicon PTR-MS Viewer software. Measurements from February 2 - February 7 have been corrected to account for an identified inlet leak. A flat subtraction was applied, and resulting compound offsets are provided in the parameter comments. Data from February 7 – February 16 have been removed due to identified leak requiring greater corrections.
Related to:
Griffith, David W T; Paton-Walsh, Clare; Naylor, Travis A; Kettlewell, Graham; Ramirez-Gamboa, Jhonathan; Simmons, Jack B; Carter, Alex; Dang, Quang Phuc; Webb, Alayna (2021): Greenhouse gases measurements at Cataract Scout Park, Australia, taken during the COALA-2020 campaign [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.927313
Griffiths, Alan D; Naylor, Travis A; Paton-Walsh, Clare; Carter, Alex (2021): Wind speed and direction measurements at Cataract Scout Park, Australia, taken during the COALA-2020 campaign [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.928929
Griffiths, Alan D; Williams, Alastair G; Chambers, Scott D; Naylor, Travis A; Simmons, Jack B; Ramirez-Gamboa, Jhonathan; Webb, Alayna; Dang, Quang Phuc; Carter, Alex; Paton-Walsh, Clare (2021): Radon-222 measurements at Cataract Scout Park, Australia, taken during the COALA-2020 campaign [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.928372
Humphries, Ruhi S; Keywood, Melita D; Paton-Walsh, Clare; Naylor, Travis A; Simmons, Jack B; Ramirez-Gamboa, Jhonathan; Carter, Alex; Dang, Quang Phuc; Webb, Alayna (2021): Aerosol size distribution measurements at Cataract Scout Park, Australia, taken during the COALA-2020 campaign [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.928853
Humphries, Ruhi S; Keywood, Melita D; Paton-Walsh, Clare; Naylor, Travis A; Simmons, Jack B; Ramirez-Gamboa, Jhonathan; Carter, Alex; Dang, Quang Phuc; Webb, Alayna (2021): Cloud condensation nuclei (CCN) measurements at Cataract Scout Park, Australia, taken during the COALA-2020 campaign [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.928925
Keywood, Melita D; Humphries, Ruhi S; Paton-Walsh, Clare; Naylor, Travis A; Ramirez-Gamboa, Jhonathan; Simmons, Jack B; Carter, Alex; Dang, Quang Phuc; Webb, Alayna (2020): Condensation nuclei >3 nm (CN3) measurements at Cataract Scout Park, Australia, taken during the COALA-2020 campaign [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.925555
Keywood, Melita D; Humphries, Ruhi S; Paton-Walsh, Clare; Naylor, Travis A; Ramirez-Gamboa, Jhonathan; Simmons, Jack B; Carter, Alex; Dang, Quang Phuc; Webb, Alayna (2021): Black carbon aerosol measurements at Cataract Scout Park, Australia, taken during the COALA-2020 campaign [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.927544
Mouat, Asher P; Paton-Walsh, Clare; Simmons, Jack B; Ramirez-Gamboa, Jhonathan; Griffith, David W T; Kaiser, Jennifer (2022): Measurement report: Observations of long-lived volatile organic compounds from the 2019–2020 Australian wildfires during the COALA campaign. Atmospheric Chemistry and Physics, 22(17), 11033-11047, https://doi.org/10.5194/acp-22-11033-2022
Naylor, Travis A; Paton-Walsh, Clare; Ramirez-Gamboa, Jhonathan; Carter, Alex; Webb, Alayna; Dang, Quang Phuc; Simmons, Jack B; Griffiths, Alan D (2021): Photosynthetically active radiation measurements at Cataract Scout Park, Australia, taken during the COALA-2020 campaign [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.928051
Simmons, Jack B; Paton-Walsh, Clare; Mouat, Asher P; Kaiser, Jennifer; Humphries, Ruhi S; Keywood, Melita D; Griffith, David W T; Sutresna, Adhitya; Naylor, Travis A; Ramirez-Gamboa, Jhonathan (accepted): Bushfire smoke plume composition and toxicological assessment from the 2019–2020 Australian Black Summer. Air Quality, Atmosphere & Health, https://doi.org/10.1007/s11869-022-01237-5
Project(s):
Coverage:
Latitude: -34.245081 * Longitude: 150.823603
Date/Time Start: 2020-02-02T01:34:00 * Date/Time End: 2020-03-19T05:15:00
Minimum HEIGHT above ground: 10.00 m * Maximum HEIGHT above ground: 10.00 m
Event(s):
Cataract_scout_park * Latitude: -34.245081 * Longitude: 150.823603 * Date/Time Start: 2020-01-18T00:00:00 * Date/Time End: 2020-03-19T00:00:00 * Location: Appin, Australia * Campaign: COALA-2020 (COALA-2020) * Method/Device: Multiple investigations (MULT)
Comment:
Empty cells = nd
COALA-2020 was funded by Australia's National Environmental Science Program through the Clean Air and Urban Landscapes hub.
Instrument precision estimated from calibration data.
Parameter(s):
# | Name | Short Name | Unit | Principal Investigator | Method/Device | Comment |
---|---|---|---|---|---|---|
1 | DATE/TIME | Date/Time | Paton-Walsh, Clare | Geocode | ||
2 | HEIGHT above ground | Height | m | Paton-Walsh, Clare | Geocode | |
3 | Methanol | CH4O | ppbv | Paton-Walsh, Clare | Proton Transfer Reaction Time of Flight Mass Spectrometer, Ionicon 4000 (PTR-ToF-MS, Ionicon 4000) | Calibrated from methanol in calibration standard, correction: 1300 pptv |
4 | Precision | Prec | pptv | Paton-Walsh, Clare | Proton Transfer Reaction Time of Flight Mass Spectrometer, Ionicon 4000 (PTR-ToF-MS, Ionicon 4000) | Instrument precision for methanol measurements |
5 | Acetonitrile | C2H3N | ppbv | Paton-Walsh, Clare | Proton Transfer Reaction Time of Flight Mass Spectrometer, Ionicon 4000 (PTR-ToF-MS, Ionicon 4000) | Calibrated from acetonitrile in calibration standard, correction: 0 pptv |
6 | Precision | Prec | pptv | Paton-Walsh, Clare | Proton Transfer Reaction Time of Flight Mass Spectrometer, Ionicon 4000 (PTR-ToF-MS, Ionicon 4000) | Instrument precision for acetonitrile measurements |
7 | Acetaldehyde | C2H4O | ppbv | Paton-Walsh, Clare | Proton Transfer Reaction Time of Flight Mass Spectrometer, Ionicon 4000 (PTR-ToF-MS, Ionicon 4000) | Calibrated from acetaldehyde in calibration standard, correction: 200 pptv |
8 | Precision | Prec | pptv | Paton-Walsh, Clare | Proton Transfer Reaction Time of Flight Mass Spectrometer, Ionicon 4000 (PTR-ToF-MS, Ionicon 4000) | Instrument precision for acetaldehyde measurements |
9 | Prop-2-enal | Acrolein (C3H4O) | ppbv | Paton-Walsh, Clare | Proton Transfer Reaction Time of Flight Mass Spectrometer, Ionicon 4000 (PTR-ToF-MS, Ionicon 4000) | Calibrated from acrolein in calibration standard, correction: 0 pptv |
10 | Precision | Prec | pptv | Paton-Walsh, Clare | Proton Transfer Reaction Time of Flight Mass Spectrometer, Ionicon 4000 (PTR-ToF-MS, Ionicon 4000) | Instrument precision for prop-2-enal measurements |
11 | Acetone | C3H6O | ppbv | Paton-Walsh, Clare | Proton Transfer Reaction Time of Flight Mass Spectrometer, Ionicon 4000 (PTR-ToF-MS, Ionicon 4000) | Calibrated from acetone in calibration standard, correction: 100 pptv |
12 | Precision | Prec | pptv | Paton-Walsh, Clare | Proton Transfer Reaction Time of Flight Mass Spectrometer, Ionicon 4000 (PTR-ToF-MS, Ionicon 4000) | Instrument precision for acetone measurements |
13 | Isoprene | C5H8 | pptv | Paton-Walsh, Clare | Proton Transfer Reaction Time of Flight Mass Spectrometer, Ionicon 4000 (PTR-ToF-MS, Ionicon 4000) | Calibrated from isoprene in calibration standard, correction: 150 pptv |
14 | Precision | Prec | pptv | Paton-Walsh, Clare | Proton Transfer Reaction Time of Flight Mass Spectrometer, Ionicon 4000 (PTR-ToF-MS, Ionicon 4000) | Instrument precision for isoprene measurements |
15 | Methacrolein + methyl vinyl ketone | MACR+MVK | ppbv | Paton-Walsh, Clare | Proton Transfer Reaction Time of Flight Mass Spectrometer, Ionicon 4000 (PTR-ToF-MS, Ionicon 4000) | Calibrated from weighted average of methacrolein and methyl vinyl ketone in calibration standard, correction: 0 pptv |
16 | Precision | Prec | pptv | Paton-Walsh, Clare | Proton Transfer Reaction Time of Flight Mass Spectrometer, Ionicon 4000 (PTR-ToF-MS, Ionicon 4000) | Instrument precision for methacrolein plus methyl vinyl ketone measurements |
17 | Butan-2-one | Methyl ethyl ketone (C4H8O) | ppbv | Paton-Walsh, Clare | Proton Transfer Reaction Time of Flight Mass Spectrometer, Ionicon 4000 (PTR-ToF-MS, Ionicon 4000) | Calibrated from methyl ethyl ketone in calibration standard, correction: 0 pptv |
18 | Precision | Prec | pptv | Paton-Walsh, Clare | Proton Transfer Reaction Time of Flight Mass Spectrometer, Ionicon 4000 (PTR-ToF-MS, Ionicon 4000) | Instrument precision for butan-2-one measurements |
19 | Benzene | C6H6 | pptv | Paton-Walsh, Clare | Proton Transfer Reaction Time of Flight Mass Spectrometer, Ionicon 4000 (PTR-ToF-MS, Ionicon 4000) | Calibrated from benzene in calibration standard, correction: 0 pptv |
20 | Precision | Prec | pptv | Paton-Walsh, Clare | Proton Transfer Reaction Time of Flight Mass Spectrometer, Ionicon 4000 (PTR-ToF-MS, Ionicon 4000) | Instrument precision for benzene measurements |
21 | Toluene | C6H5CH3 | ppbv | Paton-Walsh, Clare | Proton Transfer Reaction Time of Flight Mass Spectrometer, Ionicon 4000 (PTR-ToF-MS, Ionicon 4000) | Calibrated from toluene in calibration standard, correction: 0 pptv |
22 | Precision | Prec | pptv | Paton-Walsh, Clare | Proton Transfer Reaction Time of Flight Mass Spectrometer, Ionicon 4000 (PTR-ToF-MS, Ionicon 4000) | Instrument precision for toluene measurements |
23 | Sum C8H10 | C8H10 | ppbv | Paton-Walsh, Clare | Proton Transfer Reaction Time of Flight Mass Spectrometer, Ionicon 4000 (PTR-ToF-MS, Ionicon 4000) | Calibrated from xylene in CSIRO-provided calibration standard, correction: 100 pptv |
24 | Precision | Prec | pptv | Paton-Walsh, Clare | Proton Transfer Reaction Time of Flight Mass Spectrometer, Ionicon 4000 (PTR-ToF-MS, Ionicon 4000) | Instrument precision for sum of C8H10 measurements |
25 | Sum C9H12 | C9H12 | ppbv | Paton-Walsh, Clare | Proton Transfer Reaction Time of Flight Mass Spectrometer, Ionicon 4000 (PTR-ToF-MS, Ionicon 4000) | Calibrated from trimethylbenzene in CSIRO-provided calibration standard, correction: 0 pptv |
26 | Precision | Prec | pptv | Paton-Walsh, Clare | Proton Transfer Reaction Time of Flight Mass Spectrometer, Ionicon 4000 (PTR-ToF-MS, Ionicon 4000) | Instrument precision for sum of C9H12 measurements |
27 | Monoterpenes | Monoterpenes | ppbv | Paton-Walsh, Clare | Proton Transfer Reaction Time of Flight Mass Spectrometer, Ionicon 4000 (PTR-ToF-MS, Ionicon 4000) | Calibrated from standards using a-pinene and cineole, correction: 0 pptv |
28 | Precision | Prec | pptv | Paton-Walsh, Clare | Proton Transfer Reaction Time of Flight Mass Spectrometer, Ionicon 4000 (PTR-ToF-MS, Ionicon 4000) | Instrument precision for monoterpene measurements |
License:
Creative Commons Attribution 4.0 International (CC-BY-4.0)
Status:
Curation Level: Enhanced curation (CurationLevelC)
Size:
885045 data points
Download Data
View dataset as HTML (shows only first 2000 rows)