Reithmaier, Gloria Maria Susanne; Maher, Damien T (2020): Porewater profiles of reactive iron, sulfide and total alkalinity in mangroves (Karumba, Australia and Everglades, USA) [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.921929, In: Reithmaier, GMS; Maher, DT (2020): Soil profiles of pyrite, including underlying drivers, in coastal vegetated habitats [dataset bundled publication]. PANGAEA, https://doi.org/10.1594/PANGAEA.921934
Always quote citation above when using data! You can download the citation in several formats below.
Supplement to:
Reithmaier, Gloria Maria Susanne; Johnston, Scott G; Junginger, Tobias; Goddrad, Madeline M; Sanders, Christian J; Hutley, Lindsay B; Ho, David T; Maher, Damien T (in review): Alkalinity production coupled to pyrite formation represents unaccounted blue carbon sink. Global Biogeochemical Cycles
Further details:
American Public Health Association (APHA) (2005): Standard methods for the examination of water and wastewater. Baltimore, MD: American Public Health Association – American Water Works Association
Cline, J D (1969): Spectrophotometric determination of hydrogen sulfide in natural waters. Limnology and Oceanography, 14, 454-458, https://doi.org/10.4319/lo.1969.14.3.0454
Dickson, Andrew G (2010): Standards for Ocean Measurements. Oceanography, 23(3), 34-47, https://doi.org/10.5670/oceanog.2010.22
Coverage:
Median Latitude: 0.926490 * Median Longitude: -150.105575 * South-bound Latitude: -23.509490 * West-bound Longitude: 140.873550 * North-bound Latitude: 25.362470 * East-bound Longitude: -81.084700
Minimum DEPTH, sediment/rock: -0.900 m * Maximum DEPTH, sediment/rock: -0.025 m
Event(s):
Comment:
Porewater Fe²⁺, FeTot and sulfide (S²⁻) were measured by spectrophotometry. The 1,10-phenanthroline method was used to determine porewater Fe²⁺ and, after reducing Fe³⁺ by adding hydroxylamine, FeTot (APHA, 2005). Aqueous S⁻² was analysed using the methylene blue method (Cline, 1969). Groundwater total alkalinity was determined by a Gran titration using a titrator (Metrohm 888 Titrando with Tiamo light) with a precision better than 5 µM. Drifts and deviations in the acid concentration were corrected using certified reference materials (CRM batch 175 and CRM batch 178), as described by Dickson (2010).
Parameter(s):
# | Name | Short Name | Unit | Principal Investigator | Method/Device | Comment |
---|---|---|---|---|---|---|
1 | Event label | Event | Reithmaier, Gloria Maria Susanne | |||
2 | Latitude of event | Latitude | Reithmaier, Gloria Maria Susanne | |||
3 | Longitude of event | Longitude | Reithmaier, Gloria Maria Susanne | |||
4 | Core | Core | Reithmaier, Gloria Maria Susanne | |||
5 | Sample ID | Sample ID | Reithmaier, Gloria Maria Susanne | |||
6 | DEPTH, sediment/rock | Depth sed | m | Reithmaier, Gloria Maria Susanne | Geocode | |
7 | Iron 2+ | Fe2+ | µmol/l | Reithmaier, Gloria Maria Susanne | Photospectrometer, 1,10-Phenanthroline | |
8 | Iron | Fe | µmol/l | Reithmaier, Gloria Maria Susanne | Photospectrometer, 1,10-Phenanthroline | |
9 | Sulfide | S2- | µmol/l | Reithmaier, Gloria Maria Susanne | Photometer, methylene blue (Cline, 1969) | aequeous |
10 | Alkalinity, total | AT | µmol/kg | Reithmaier, Gloria Maria Susanne | Alkalinity, Gran titration (Gran, 1950) |
License:
Creative Commons Attribution 4.0 International (CC-BY-4.0)
Size:
240 data points