| # | Name | Short Name | Unit | Principal Investigator | Method/Device | Comment |
| 1 | DATE/TIME | Date/Time | | Tooze, Sian | | Geocode |
| 2 | Sample ID | Sample ID | | Tooze, Sian | | |
| 3 | Analysis | Analysis | | Tooze, Sian | | ID |
| 4 | Lithology/composition/facies | Lithology | | Tooze, Sian | Laser-ablation inductively coupled plasma mass spectrometer (LA-ICP-MS) | |
| 5 | Mineral name | Mineral | | Tooze, Sian | Laser-ablation inductively coupled plasma mass spectrometer (LA-ICP-MS) | |
| 6 | Operation mode | Op mode | | Tooze, Sian | Laser-ablation inductively coupled plasma mass spectrometer (LA-ICP-MS) | |
| 7 | Size | Size | µm | Tooze, Sian | Laser-ablation inductively coupled plasma mass spectrometer (LA-ICP-MS) | Spot size |
| 8 | Time in seconds | Time sec | s | Tooze, Sian | Laser-ablation inductively coupled plasma mass spectrometer (LA-ICP-MS) | Ablation duration |
| 9 | Sample rate | Rate | Hz | Tooze, Sian | Laser-ablation inductively coupled plasma mass spectrometer (LA-ICP-MS) | Repition rate |
| 10 | Fluence | Fluence | J/cm2 | Tooze, Sian | Laser-ablation inductively coupled plasma mass spectrometer (LA-ICP-MS) | |
| 11 | Uranium-238/Lead-206 ratio | 238U/206Pb | | Tooze, Sian | Laser-ablation inductively coupled plasma mass spectrometer (LA-ICP-MS) | |
| 12 | Uranium-238/Lead-206 ratio, standard error | 238U/206Pb std e | ± | Tooze, Sian | Laser-ablation inductively coupled plasma mass spectrometer (LA-ICP-MS) | +/- 1 sigma |
| 13 | Lead-207/Lead-206 ratio | 207Pb/206Pb | | Tooze, Sian | Laser-ablation inductively coupled plasma mass spectrometer (LA-ICP-MS) | |
| 14 | Lead-207/Lead-206 ratio, standard error | 207Pb/206Pb std e | ± | Tooze, Sian | Laser-ablation inductively coupled plasma mass spectrometer (LA-ICP-MS) | +/- 1sigma |
| 15 | Lead, common | Pb com | mg/kg | Tooze, Sian | Laser-ablation inductively coupled plasma mass spectrometer (LA-ICP-MS) | Common Pb for mineral 1st iteration using the method outlined in Chew et al. (2011) |
| 16 | Lead, standard deviation | Pb std dev | ± | Tooze, Sian | Laser-ablation inductively coupled plasma mass spectrometer (LA-ICP-MS) | Cf common Pb for mineral 1st iteration using the method outlined in Chew et al. (2011) |
| 17 | Lead, common | Pb com | mg/kg | Tooze, Sian | Laser-ablation inductively coupled plasma mass spectrometer (LA-ICP-MS) | Common Pb for mineral 5thiteration using the method outlined in Chew et al. (2011) |
| 18 | Lead, standard deviation | Pb std dev | ± | Tooze, Sian | Laser-ablation inductively coupled plasma mass spectrometer (LA-ICP-MS) | Cf common Pb for mineral 5th iteration using the method outlined in Chew et al. (2011) |
| 19 | Age model | Age model | ka | Tooze, Sian | Lead 207-corrected | 207 cor 206Pb/238U for mineral 1st iteration using the method outlined in Chew et al. (2011) |
| 20 | Age, standard error | Age std e | ± | Tooze, Sian | Lead 207-corrected | +/- 1sigma, 207 cor 206Pb/238U for mineral 1st iteration using the method outlined in Chew et al. (2011) |
| 21 | Age model | Age model | ka | Tooze, Sian | Lead 207-corrected | 207 cor 206Pb/238U for mineral 5th iteration using the method outlined in Chew et al. (2011) |
| 22 | Age, standard error | Age std e | ± | Tooze, Sian | Lead 207-corrected | +/- 1sigma, 207 cor 206Pb/238U for mineral 5th iteration using the method outlined in Chew et al. (2011) |
| 23 | Age model | Age model | ka | Tooze, Sian | Age, 206Pb/238U Lead-Uranium | |
| 24 | Age, standard error | Age std e | ± | Tooze, Sian | Age, 206Pb/238U Lead-Uranium | +/- 1sigma |
| 25 | Age model | Age model | ka | Tooze, Sian | Age, 208Pb/232Th Lead-Thorium | |
| 26 | Age, standard error | Age std e | ± | Tooze, Sian | Age, 208Pb/232Th Lead-Thorium | +/- 1sigma |
| 27 | Age model | Age model | ka | Tooze, Sian | Age, 207Pb/206Pb Lead-Lead | |
| 28 | Age, standard error | Age std e | ± | Tooze, Sian | Age, 207Pb/206Pb Lead-Lead | +/- 1sigma |
| 29 | Percentage | Perc | % | Tooze, Sian | Laser-ablation inductively coupled plasma mass spectrometer (LA-ICP-MS) | Concordance |
| 30 | Phosphorus | P | mg/kg | Tooze, Sian | Laser-ablation inductively coupled plasma mass spectrometer (LA-ICP-MS) | P31, original value in ppm |
| 31 | Titanium | Ti | mg/kg | Tooze, Sian | Laser-ablation inductively coupled plasma mass spectrometer (LA-ICP-MS) | Ti49, original value in ppm |
| 32 | Iron | Fe | mg/kg | Tooze, Sian | Laser-ablation inductively coupled plasma mass spectrometer (LA-ICP-MS) | Fe56, original value in ppm |
| 33 | Yttrium | Y | mg/kg | Tooze, Sian | Laser-ablation inductively coupled plasma mass spectrometer (LA-ICP-MS) | Y89, original value in ppm |
| 34 | Zirconium | Zr | mg/kg | Tooze, Sian | Laser-ablation inductively coupled plasma mass spectrometer (LA-ICP-MS) | Zr91, original value in ppm |
| 35 | Niobium | Nb | mg/kg | Tooze, Sian | Laser-ablation inductively coupled plasma mass spectrometer (LA-ICP-MS) | Nb93, original value in ppm |
| 36 | Lanthanum | La | mg/kg | Tooze, Sian | Laser-ablation inductively coupled plasma mass spectrometer (LA-ICP-MS) | La139, original value in ppm |
| 37 | Cerium | Ce | mg/kg | Tooze, Sian | Laser-ablation inductively coupled plasma mass spectrometer (LA-ICP-MS) | Ce140, original value in ppm |
| 38 | Praseodymium | Pr | mg/kg | Tooze, Sian | Laser-ablation inductively coupled plasma mass spectrometer (LA-ICP-MS) | Pr141, original value in ppm |
| 39 | Neodymium | Nd | mg/kg | Tooze, Sian | Laser-ablation inductively coupled plasma mass spectrometer (LA-ICP-MS) | Nd146, original value in ppm |
| 40 | Samarium | Sm | mg/kg | Tooze, Sian | Laser-ablation inductively coupled plasma mass spectrometer (LA-ICP-MS) | Sm147, original value in ppm |
| 41 | Europium | Eu | mg/kg | Tooze, Sian | Laser-ablation inductively coupled plasma mass spectrometer (LA-ICP-MS) | Eu153, original value in ppm |
| 42 | Gadolinium | Gd | mg/kg | Tooze, Sian | Laser-ablation inductively coupled plasma mass spectrometer (LA-ICP-MS) | 157, original value in ppm |
| 43 | Terbium | Tb | mg/kg | Tooze, Sian | Laser-ablation inductively coupled plasma mass spectrometer (LA-ICP-MS) | Tb159, original value in ppm |
| 44 | Dysprosium | Dy | mg/kg | Tooze, Sian | Laser-ablation inductively coupled plasma mass spectrometer (LA-ICP-MS) | Dy163, original value in ppm |
| 45 | Holmium | Ho | mg/kg | Tooze, Sian | Laser-ablation inductively coupled plasma mass spectrometer (LA-ICP-MS) | Ho165, original value in ppm |
| 46 | Erbium | Er | mg/kg | Tooze, Sian | Laser-ablation inductively coupled plasma mass spectrometer (LA-ICP-MS) | Er166, original value in ppm |
| 47 | Thulium | Tm | mg/kg | Tooze, Sian | Laser-ablation inductively coupled plasma mass spectrometer (LA-ICP-MS) | Tm169, original value in ppm |
| 48 | Ytterbium | Yb | mg/kg | Tooze, Sian | Laser-ablation inductively coupled plasma mass spectrometer (LA-ICP-MS) | Yb172, original value in ppm |
| 49 | Lutetium | Lu | mg/kg | Tooze, Sian | Laser-ablation inductively coupled plasma mass spectrometer (LA-ICP-MS) | Lu175, original value in ppm |
| 50 | Hafnium | Hf | mg/kg | Tooze, Sian | Laser-ablation inductively coupled plasma mass spectrometer (LA-ICP-MS) | Hf178, original value in ppm |
| 51 | Tantalum | Ta | mg/kg | Tooze, Sian | Laser-ablation inductively coupled plasma mass spectrometer (LA-ICP-MS) | Ta181, original value in ppm |
| 52 | Lead | Pb | mg/kg | Tooze, Sian | Laser-ablation inductively coupled plasma mass spectrometer (LA-ICP-MS) | Pb207, original value in ppm |
| 53 | Lead | Pb | mg/kg | Tooze, Sian | Laser-ablation inductively coupled plasma mass spectrometer (LA-ICP-MS) | Pb208, original value in ppm |
| 54 | Lead | Pb | mg/kg | Tooze, Sian | Laser-ablation inductively coupled plasma mass spectrometer (LA-ICP-MS) | Pb207, original value in ppm |
| 55 | Lead | Pb | mg/kg | Tooze, Sian | Laser-ablation inductively coupled plasma mass spectrometer (LA-ICP-MS) | Pb208, original value in ppm |
| 56 | Thorium | Th | mg/kg | Tooze, Sian | Laser-ablation inductively coupled plasma mass spectrometer (LA-ICP-MS) | Th232, original value in ppm |
| 57 | Uranium | U | mg/kg | Tooze, Sian | Laser-ablation inductively coupled plasma mass spectrometer (LA-ICP-MS) | U238, original value in ppm |
| 58 | Calcium | Ca | mg/kg | Tooze, Sian | Laser-ablation inductively coupled plasma mass spectrometer (LA-ICP-MS) | Ca43, original value in ppm |