Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

Ransby, Daniela; Fischer, Helmut W; Hettwig, Bernd; Enters, Dirk (2020): Gamma emitting radionuclides and age model of sediment core SIS11-3 from Silbersee, North Germany [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.914844

Always quote citation above when using data! You can download the citation in several formats below.

Published: 2020-04-16 • DOI registered: 2020-05-15

RIS CitationBibTeX Citation ShareShow MapGoogle Earth

Abstract:
The chronology of the top part of the core SIS11-3 is based on excess 210Pb and anthropogenic gamma emitting radionuclides. The analyses of samples down to 66 cm depth were conducted by gamma spectrometry with a reverse electrode coaxial HPGe detector. The efficiencies for the factory characterized detector were calculated using LabSOCS (Laboratory SOurceless Calibration System), a Genie 2000 software calibration tool, based on defined sample to detector geometry and sample density and composition.
Due to the low masses of the 1 cm sediment core increments, each time three freeze-dried 1 cm intervals were pooled, i.e. three of the small sample containers were placed side by side in a triangular arrangement onto the detector front window. Because of the long measurement times needed and limitations in detector time, every second of these pooled samples was measured, plus an additional sample at 60-63 cm.
Keyword(s):
lake sediments; Radionuclides
Coverage:
Latitude: 53.490400 * Longitude: 8.810000
Minimum DEPTH, sediment/rock: 0.0450 m * Maximum DEPTH, sediment/rock: 0.6450 m
Event(s):
SIS11-3 * Latitude: 53.490400 * Longitude: 8.810000 * Recovery: 0.82 m * Location: Silbersee, Lower Saxony, Germany * Method/Device: Gravity corer, UWITEC (GCUWI) * Comment: Coring date: 2011; deepest part of the lake; core diameter: 63 mm
Comment:
Gamma spectrometry was performed in the Bremen State Radioactivity Measurements Laboratory (Landesmessstelle für Radioaktivität), Institute of Environmental Physics, University of Bremen.
All activity concentrations are reported per mass dry sediment.
For the sediment chronology, the piecewise Constant Flux - Constant Sedimentation (CF-CS) model was applied. The deepest analyzed sample was excluded from the analysis, because it likely represents a much older material (below hiatus).
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
1CommentCommentRansby, DanielaHigh resolution, low background gamma spectroscopy (HPGe detector, Canberra Inc.)Spectrum number (LMS Bremen)
2DEPTH, sediment/rockDepth sedmRansby, DanielaGeocode
3Depth, top/minDepth topmRansby, Daniela
4Depth, bottom/maxDepth botmRansby, Daniela
5Depth, compositeDepth compmcdRansby, Danieladepth of DBD
6Density, dry bulkDBDg/cm3Enters, Dirk
7Cumulative massCum massg/cm2Ransby, Daniela
8Potassium-4040KBq/kgRansby, DanielaHigh resolution, low background gamma spectroscopy (HPGe detector, Canberra Inc.)
9Potassium-40, standard deviation40K std dev±Ransby, DanielaHigh resolution, low background gamma spectroscopy (HPGe detector, Canberra Inc.)uncertainty (Bq/kg)
10Caesium-137137CsBq/kgRansby, DanielaHigh resolution, low background gamma spectroscopy (HPGe detector, Canberra Inc.)
11Caesium-137, standard deviation137Cs std dev±Ransby, DanielaHigh resolution, low background gamma spectroscopy (HPGe detector, Canberra Inc.)uncertainty (Bq/kg)
12Lead-210210PbBq/kgRansby, DanielaHigh resolution, low background gamma spectroscopy (HPGe detector, Canberra Inc.)total 210Pb
13Lead-210, standard deviation210Pb std dev±Ransby, DanielaHigh resolution, low background gamma spectroscopy (HPGe detector, Canberra Inc.)uncertainty (Bq/kg)
14Bismuth-214214BiBq/kgRansby, DanielaHigh resolution, low background gamma spectroscopy (HPGe detector, Canberra Inc.)
15Bismuth-214, standard deviation214Bi std dev±Ransby, DanielaHigh resolution, low background gamma spectroscopy (HPGe detector, Canberra Inc.)uncertainty (Bq/kg)
16Lead-214214PbBq/kgRansby, DanielaHigh resolution, low background gamma spectroscopy (HPGe detector, Canberra Inc.)supported 210Pb
17Lead-214, standard deviation214Pb std dev±Ransby, DanielaHigh resolution, low background gamma spectroscopy (HPGe detector, Canberra Inc.)uncertainty (Bq/kg)
18Americium-241241AmBq/kgRansby, DanielaHigh resolution, low background gamma spectroscopy (HPGe detector, Canberra Inc.)
19Americium-241, standard deviation241Am std dev±Ransby, DanielaHigh resolution, low background gamma spectroscopy (HPGe detector, Canberra Inc.)uncertainty (Bq/kg)
20CommentCommentRansby, DanielaHigh resolution, low background gamma spectroscopy (HPGe detector, Canberra Inc.)214Am excluded: high uncertainty
21Americium-241 decision threshold241Am d tBq/kgRansby, DanielaHigh resolution, low background gamma spectroscopy (HPGe detector, Canberra Inc.)
22Lead-210 excess210Pb xsBq/kgRansby, DanielaHigh resolution, low background gamma spectroscopy (HPGe detector, Canberra Inc.)=total 210Pb - supported 210Pb
23Lead-210 excess, standard deviation210Pb xs std dev±Ransby, DanielaHigh resolution, low background gamma spectroscopy (HPGe detector, Canberra Inc.)uncertainty (Bq/kg)
24Accumulation rate per yearAcc rateg/cm2/aRansby, DanielaCF-CS model (2 sections)
25Accumulation rate, standard deviationAcc rate std dev±Ransby, DanielaCF-CS model (2 sections)
26Sedimentation rate per yearSRcm/aRansby, DanielaCF-CS model (2 sections)
27Sedimentation rate, standard deviationSR std dev±Ransby, DanielaCF-CS model (2 sections)
28Age, commentCommRansby, DanielaCF-CS model (2 sections)age in years from the sampling date: 2011 AD
29Age, standard deviationAge std dev±Ransby, DanielaCF-CS model (2 sections)
30AgeAgea AD/CERansby, DanielaCF-CS model (2 sections)
31AGEAgeka BPRansby, DanielaCF-CS model (2 sections)Geocode
32Age, lower confidence levelAge LCLa AD/CERansby, DanielaCF-CS model (2 sections)
33Age, upper confidence levelAge UCLa AD/CERansby, DanielaCF-CS model (2 sections)
Size:
336 data points

Download Data

Download dataset as tab-delimited text — use the following character encoding:

View dataset as HTML