Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

Hasberg, Ascelina; Bijaksana, Satria; Held, Peter; Just, Janna; Melles, Martin; Morlock, Marina A; Opitz, Stephan; Russell, James M; Vogel, Hendrik; Wennrich, Volker (2020): Non-destructive particle analyses from different surface sediment samples of Lake Towuti, Indonesia [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.914843

Always quote citation above when using data! You can download the citation in several formats below.

Published: 2020-04-16DOI registered: 2020-06-02

RIS CitationBibTeX Citation ShareShow MapGoogle Earth

Abstract:
At the University of Cologne, Germany, a subsample was taken from one aliquot and used to produce smear slides for identification of sedimentary components using transmitted light microscopy. On selected samples, sponge spicules and diatom frustules were additionally investigated using a Zeiss Gemini Sigma 300VP scanning electron microscope (SEM; Carl Zeiss AG, Oberkochen, Germany). Furthermore, some magnetic mineral grains were identified with energy dispersive X-ray spectroscopy (EDX) of the Sigma SEM system.
Based on smear slide analyses, a set of 40 samples that contain sponge spicules, diatoms and/or tephra particles were selected for automated, non-destructive particle image analyses using a dynamic imaging system (Benchtop B3 Series VS FlowCAM®; Fluid Imaging Technologies, Inc., Scarborough, ME, USA) to quantify the abundance of these particles. Aliquots of wet bulk samples were treated with hydrogen peroxide (H2O2; 30%) for seven days at room temperature to remove organic matter (OM) and disaggregate the siliceous biogenic particles, and were subsequently sieved with 25 and 80 µm meshes. The pre-treated sample fractions were diluted with deionized water (samples <25 µm) or polyvinyl pyrrolidone (PVP, 2 %; samples 25 to 80 µm and >80 µm). Particle recording in the <25 µm and 25 to 80 µm fractions was carried out using a 100 µm flowcell, a 10x objective lens with a collimator, and a 1 ml syringe-pump (flow rate 0.3 ml/min), whereas the >80 µm fraction was recorded using a 300 µm flowcell, a 4x objective lens without collimator, and a 5 ml syringe-pump (flow rate 0.6 ml/min). Data were acquired using the software VisualSpreadsheet (Fluid Imaging Technologies, Inc., Scarborough, ME, USA) until 10.000 images were recorded or 30 ml of the sample was investigated. An automated catalogue based on training sets developed for sponge spicules, diatoms and tephra particles was compiled to differentiate and group components with comparable characteristics in the measured sample fractions.
Keyword(s):
Indo-Pacific Warm Pool (IPWP); Lake Towuti; modern sedimentation; provenance analysis; Redox conditions; tropical lake
Related to:
Hasberg, Ascelina; Bijaksana, Satria; Held, Peter; Just, Janna; Melles, Martin; Morlock, Marina A; Opitz, Stephan; Russell, James M; Vogel, Hendrik; Wennrich, Volker (2019): Modern sedimentation processes in Lake Towuti, Indonesia, revealed by the composition of surface sediments. Sedimentology, 66(2), 675-698, https://doi.org/10.1111/sed.12503
Coverage:
Median Latitude: -2.759479 * Median Longitude: 121.512143 * South-bound Latitude: -2.932300 * West-bound Longitude: 120.951200 * North-bound Latitude: -2.652500 * East-bound Longitude: 121.664700
Minimum DEPTH, sediment/rock: m * Maximum DEPTH, sediment/rock: m
Event(s):
Lake_Towuti-01 * Latitude: -2.668200 * Longitude: 121.420600 * Lake water depth: 6.3 m
Lake_Towuti-02 * Latitude: -2.652500 * Longitude: 121.441000 * Lake water depth: 5.4 m
Lake_Towuti-03 * Latitude: -2.669200 * Longitude: 121.454800 * Lake water depth: 48.4 m
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
1Event labelEventHasberg, Ascelina
2Latitude of eventLatitudeHasberg, Ascelina
3Longitude of eventLongitudeHasberg, Ascelina
4Depth, bathymetricBathy depthmHasberg, AscelinaLake water depth
5Station labelStationHasberg, AscelinaSediment surface sample number
6DEPTH, sediment/rockDepth sedmHasberg, AscelinaGeocode
7ParticlesParticles#Hasberg, AscelinaBenchtop B3 Series VS FlowCAMTephra particle per 1000 particle
8ParticlesParticles#Hasberg, AscelinaBenchtop B3 Series VS FlowCAMDiatom particle per 1000 particle
9ParticlesParticles#Hasberg, AscelinaBenchtop B3 Series VS FlowCAMSpicule particle per 1000 particle
Size:
288 data points

Download Data

Download dataset as tab-delimited text — use the following character encoding:

View dataset as HTML