Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

Rutledal, Sunniva; Berben, Sarah M P; Dokken, Trond; van der Bilt, Willem G M; Cederstrøm, Jan Magne; Jansen, Eystein (2020): Geochemical composition of tephra layers from deep sediment core GS16-204-22CC-A, Labrador Sea, North Atlantic [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.913645, In: Rutledal, S et al. (2020): Shard concentrations and geochemical composition of tephra layers from deep sediment cores MD99-2284, GS16-204-22CC and GS16-204-18CC. Tephra horizons identified in the western North Atlantic and Nordic Seas during the Last Glacial Period [dataset publication series]. PANGAEA, https://doi.org/10.1594/PANGAEA.913678

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Coverage:
Latitude: 58.047167 * Longitude: -47.039333
Date/Time Start: 2016-08-28T00:00:00 * Date/Time End: 2016-08-28T00:00:00
Minimum Elevation: -3160.0 m * Maximum Elevation: -3160.0 m
Event(s):
GS16-204-22CC-A * Latitude: 58.047167 * Longitude: -47.039333 * Date/Time: 2016-08-28T00:00:00 * Elevation: -3160.0 m * Campaign: GS2016-204 * Basis: G. O. Sars (2003) * Method/Device: Calypso Corer (CALYPSO)
Comment:
Electron-probe microanalysis (EPMA). These measurements were performed at the Tephrochronological Analytical Unit at the University of Edinburgh using a Cameca SX100 electron microprobe with five vertical wavelength dispersive spectrometers, providing oxide values (wt. %) for 10 major elements (see supplementary information).
Beam size: 5
Settings:
cond1: Na, Al, Si, K†, Ca, Fe, Mg
cond2: Mn, P†, Ti
Size:
2628 data points

Data

Download dataset as tab-delimited text — use the following character encoding:


Depth top [m]

Depth bot [m]

Size fraction

Sample label

SiO2 [%]

TiO2 [%]

Al2O3 [%]

FeO [%]

MnO [%]
10 
MgO [%]
11 
CaO [%]
12 
Na2O [%]
13 
K2O [%]
14 
P2O5 [%]
15 
Sum [%]
16 
TG Pop
17 
Date
18 
Method comm
201201.5>125 um149.20562.960113.082214.19350.20635.28999.81882.74980.40730.345598.2589Mix2018-06-14Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
201201.5>125 um246.16393.914713.631013.43850.19175.695510.71742.92760.70230.362297.7447Mix2018-06-14Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
201201.5>125 um346.66194.315713.081314.36970.20765.45159.99993.14680.67390.556498.4647Mix2018-06-14Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
201201.5>125 um447.63523.709612.980114.31580.21695.18109.74073.42500.70700.533398.4447Mix2018-06-14Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
201201.5>125 um549.28241.777013.498912.91760.21676.700210.98702.46760.19700.200398.2446Mix2018-06-14Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
201201.5>125 um649.02033.604312.671615.01250.24044.64358.94073.16430.57410.437598.3093Mix2018-06-14Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
201201.5>125 um746.01614.461213.184814.02030.21025.527410.40342.96720.73020.473297.9940Mix2018-06-14Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
201201.5>125 um848.79373.613312.500614.56900.23364.65588.66353.00840.62190.465597.1253Mix2018-06-14Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
201201.580-125 um152.08951.846013.849712.36550.19925.567010.21872.86060.35220.206299.5547Mix2018-06-15Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
201201.580-125 um249.39993.600912.640814.96900.23154.79488.96013.03370.50690.397498.5350Mix2018-06-15Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
201201.580-125 um347.43574.168412.785814.00460.22304.44279.02713.43670.94520.528796.9979Mix2018-06-15Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
201201.580-125 um449.25773.659712.351014.82030.23804.74108.80483.17930.52360.414197.9894Mix2018-06-15Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
201201.580-125 um547.84013.967913.016114.15380.19634.78419.41323.24940.78090.588897.9905Mix2018-06-15Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
201201.580-125 um648.57123.677713.162013.23230.22724.10708.90023.51871.00420.762997.1635Mix2018-06-15Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
201201.580-125 um748.62174.145213.699414.10880.17076.16759.85362.09570.66470.381499.9087Mix2018-06-15Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
201201.525-80um149.68673.596912.738614.57230.24554.48388.73323.06280.58500.446298.1508FMAZ II-12018-06-14Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
201201.525-80um249.66683.600212.747114.67310.22854.53638.92553.14940.54640.458998.5322FMAZ II-12018-06-14Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
201201.525-80um349.93603.594312.459815.13120.22964.62378.77323.09460.62590.452698.9210FMAZ II-12018-06-14Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
201201.525-80um449.24763.568712.849214.93450.23234.77748.87913.10330.59250.444898.6293FMAZ II-12018-06-14Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
201201.525-80um549.50773.515012.889114.95500.23584.55589.09233.05820.53420.395898.7390FMAZ II-12018-06-14Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
201201.525-80um649.75023.641012.747214.86320.24514.29058.58613.11050.51180.430998.1763FMAZ II-12018-06-14Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
201201.525-80um749.65183.613312.692114.63160.22844.50948.80483.05190.51370.441298.1382FMAZ II-12018-06-14Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
201201.525-80um849.84313.630212.807115.02760.23044.38588.82953.15150.58520.439698.9302FMAZ II-12018-06-14Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
201201.525-80um949.48183.623312.626915.18180.23754.56848.73753.11560.63540.425598.6337FMAZ II-12018-06-14Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
201201.525-80um1050.12833.644112.785414.82880.23354.46708.85223.17330.60730.407299.1271FMAZ II-12018-06-14Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
201201.525-80um1149.34743.634612.604514.69910.21804.61528.88993.05170.56550.433598.0595FMAZ II-12018-06-14Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
201201.525-80um1250.74313.647713.037414.97130.25164.59768.98791.76650.55150.420698.9752Mix2018-06-14Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
201201.525-80um1351.95723.296212.585713.64980.24203.67997.78043.14150.70210.641197.6759Mix2018-06-14Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
201201.525-80um1451.64883.339012.505313.78910.25013.78138.19993.27850.73470.584198.1109Mix2018-06-14Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
201201.525-80um1548.69323.970412.887413.63040.19014.94329.22923.51880.87970.542298.4845Mix2018-06-14Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
201201.525-80um1651.99073.343612.912114.06510.22413.81118.03853.35200.69580.563198.9961Mix2018-06-14Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
201201.525-80um1747.48604.626613.213014.20010.19895.622711.36882.06520.65570.472799.9095Mix2018-06-14Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
196196.5>125 um149.21693.802412.465914.28280.27034.25798.72483.63440.93971.252998.8480Mix2019-02-25Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
196196.5>125 um249.65812.515213.266713.21010.21686.243511.05452.38740.30940.239999.1015Mix2019-02-25Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
196196.5>125 um349.22232.511712.914513.37450.22736.342311.26022.57630.35580.231299.0162Mix2019-02-25Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
196196.5>125 um453.58593.391613.254111.35600.23023.08868.03592.80110.39830.412596.5542Mix2019-02-25Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
196196.5>125 um548.46823.700412.676914.53680.27194.19298.50373.60370.93571.206698.0967Mix2019-02-25Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
196196.5>125 um650.21643.766612.795314.56640.27604.19788.82191.42630.97881.242198.2876Mix2019-02-25Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
196196.5>125 um748.94043.649812.368914.79870.24244.67898.79473.03340.50870.419197.4349FMAZ II-12019-02-25Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
196196.5>125 um849.39921.763512.935913.41030.20896.547711.04382.28100.20310.185797.9791Mix2019-02-25Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
196196.5>125 um947.39694.077413.290413.62210.21345.645710.52862.90770.63280.404598.7194Mix2019-02-25Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
196196.5>125 um1050.02161.766913.537313.00410.22336.472910.91362.27620.18090.183098.5798Mix2019-02-25Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
196196.5>125 um1148.91031.657814.392010.89680.20927.467412.09942.14250.23960.175898.1907Mix2019-02-25Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
196196.5>125 um1249.79613.642412.392914.37740.24434.55028.62502.98590.57420.457297.6456FMAZ II-12019-02-25Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
196196.5>125 um1348.12204.208812.431314.86430.27284.47028.91273.38230.77700.905698.3471Mix2019-02-25Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
196196.5>125 um1449.12553.033613.074215.02810.22045.39289.68702.87390.43650.277699.1496Mix2019-02-25Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
196196.5>125 um1554.06863.018112.971212.82180.24853.31037.46363.32380.84210.619898.6878Mix2019-02-25Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
196196.5>125 um1647.79193.856612.734614.37130.26494.26978.93803.63300.94101.261698.0627Mix2019-02-25Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
196196.580-125 um149.34513.330112.572914.49480.24494.73589.07563.03370.53850.363097.7342FMAZ II-12019-02-26Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
196196.580-125 um248.83803.631212.512114.60920.24514.70549.06852.99440.50000.400797.5046FMAZ II-12019-02-26Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
196196.580-125 um349.32843.499812.247615.44620.23774.54768.62332.96560.58460.389997.8706FMAZ II-12019-02-26Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
196196.580-125 um448.31154.382812.783814.19380.23554.47579.11163.35420.67770.628698.1551FMAZ II-12019-02-26Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
196196.580-125 um547.08274.225812.384314.54920.26264.50438.98263.40570.81610.870397.0838Mix2019-02-26Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
196196.580-125 um648.97873.033013.134714.74900.24535.28699.69162.72160.43030.284898.5559Mix2019-02-26Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
196196.580-125 um748.64213.683212.725714.25260.27974.04208.55933.70070.95071.228398.0643Mix2019-02-26Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
196196.580-125 um847.92874.442712.452815.04910.24624.68139.47913.34560.79300.686599.1051Mix2019-02-26Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
196196.580-125 um947.35764.528012.279114.75870.23074.73129.38443.20570.77720.644097.8966Mix2019-02-26Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
196196.580-125 um1049.10613.199812.910714.44870.22844.85769.36323.09700.59400.349098.1547FMAZ II-12019-02-26Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
196196.580-125 um1148.87883.622712.469114.99310.23814.58359.05343.17490.51250.390297.9163FMAZ II-12019-02-26Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
196196.580-125 um1250.46172.133012.927014.66310.24025.406010.21312.42870.25170.210698.9350Mix2019-02-26Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
196196.525-80um148.78463.705012.223414.37940.26934.07338.91383.16230.89801.250097.6592Mix2019-02-26Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
196196.525-80um248.44053.017612.826614.06260.20925.45599.65952.71710.38640.329997.1055Mix2019-02-26Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
196196.525-80um347.94184.230712.151314.20260.24304.52739.23183.38660.83120.843897.5898Mix2019-02-26Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
196196.525-80um449.65603.524412.532514.00160.22984.40958.57183.00320.69390.464697.0873Mix2019-02-26Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
196196.525-80um548.99223.765712.712314.63280.26724.15458.75553.64360.94451.281599.1497Mix2019-02-26Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
196196.525-80um650.13003.538914.205013.24950.23703.51578.87933.91891.09170.979199.7453Mix2019-02-26Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
196196.525-80um748.55333.596112.992814.12280.27653.92538.52053.71120.90611.332397.9370Mix2019-02-26Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
196196.525-80um847.98363.703212.755914.14240.26484.09208.50963.62780.90661.252897.2388Mix2019-02-26Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
196196.525-80um947.73983.790612.390314.31690.26144.38488.80883.60070.90051.174497.3682Mix2019-02-26Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
196196.525-80um1048.67572.801712.640014.18320.22165.62899.95522.58490.44430.306597.4419Mix2019-02-26Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
196196.525-80um1148.65913.945312.264014.43240.25934.27008.79373.27790.83301.071497.8060Mix2019-02-26Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
196196.525-80um1248.14634.086212.215814.02930.23414.59918.81083.45720.95660.575297.1106Mix2019-02-26Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
196196.525-80um1349.34171.366313.828510.87580.19677.803212.18972.23660.26580.122798.2269Mix2019-02-26Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
196196.525-80um1451.53463.377712.435914.01950.24353.66778.16593.11900.69220.567097.8229Mix2019-02-26Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
196196.525-80um1548.91163.612412.229214.57240.23694.45239.04143.07300.52820.421397.0786FMAZ II-12019-02-26Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
196196.525-80um1651.79553.269713.216212.30610.21833.67647.61003.67281.28720.586297.6384Mix2019-02-26Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
196196.525-80um1749.18353.515612.253315.47490.25164.58749.05242.89980.53600.395098.1494FMAZ II-12019-02-26Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
196196.525-80um1854.16922.901412.670713.27670.26443.17297.30383.28820.76220.606998.4164Mix2019-02-26Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
196196.525-80um1949.09483.393512.888015.06430.25254.55868.93182.92180.54410.390298.0397FMAZ II-12019-02-26Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
196196.525-80um2048.84623.612612.355214.77860.24564.51748.73252.97550.56290.417597.0440FMAZ II-12019-02-26Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
196196.525-80um2146.91134.430712.426014.74060.24854.62569.28143.40690.74550.707297.5237Mix2019-02-26Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
196196.525-80um2248.01523.569612.430814.93000.25274.75799.14393.12790.51970.391597.1392FMAZ II-12019-02-26Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
196196.525-80um2347.27944.356112.443414.27430.24034.53029.09083.38810.72400.773497.1000Mix2019-02-26Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
196196.525-80um2448.50323.658912.633814.47570.28084.16648.64183.66570.93291.270698.2298Mix2019-02-26Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
196196.525-80um2548.63423.757212.087514.24600.25554.00838.49703.70390.99691.226897.4132Mix2019-02-26Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
196196.525-80um2649.21143.605612.472514.65020.24504.60678.89353.02980.64840.432197.7951FMAZ II-12019-02-26Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
196196.525-80um2748.62373.600012.619414.04170.27623.95948.34733.63930.91951.281197.3075Mix2019-02-26Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
196196.525-80um2851.63982.732712.901313.25580.21004.73458.69552.92140.71420.342998.1480Mix2019-02-26Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
196196.525-80um2949.27713.145312.575013.89350.21924.99869.36433.01100.58140.346097.4113FMAZ II-12019-02-26Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
196196.525-80um3049.08553.505011.968815.07990.23514.61569.13342.98930.58130.408197.6019FMAZ II-12019-02-26Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
196196.525-80um3146.69174.367112.357214.42700.24884.63579.43633.41600.80210.721297.1029Mix2019-02-26Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
196196.525-80um3252.97313.034812.660413.24810.27523.45487.53803.30430.87500.632897.9967Mix2019-02-26Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
196196.525-80um3350.95822.021013.595312.75270.20635.64219.97852.90920.33350.208298.6049Mix2019-02-26Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
196196.525-80um3453.18202.865712.499513.03120.25943.19287.38423.35070.78740.614597.1674Mix2019-02-26Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
196196.525-80um3549.88243.345612.384014.42630.24144.49138.79822.90200.57410.366597.4118FMAZ II-12019-02-26Cond 1: 15 keV 2nA, Cond 2: 15 keV 80 nA
474474.5>125 µm172.29000.160010.88002.40000.07000.03000.45005.22003.68000.010095.1800NAAZ II (II-RHY-1)2018-01-15Cond 1: 15 keV 0.5nA, Cond 2: 15 keV 2nA, Cond 3: 15 keV 60 nA
474474.5>125 µm271.53000.150011.17002.55000.07000.01000.42004.84003.70000.010094.4500NAAZ II (II-RHY-1)2018-01-15Cond 1: 15 keV 0.5nA, Cond 2: 15 keV 2nA, Cond 3: 15 keV 60 nA
474474.5>125 µm370.69000.190011.43002.52000.0600-0.01000.49004.97003.74000.000094.0800NAAZ II (II-RHY-1)2018-01-15Cond 1: 15 keV 0.5nA, Cond 2: 15 keV 2nA, Cond 3: 15 keV 60 nA
474474.5>125 µm471.25000.160011.03002.48000.0600-0.02000.39005.41003.85000.010094.6300NAAZ II (II-RHY-1)2018-01-15Cond 1: 15 keV 0.5nA, Cond 2: 15 keV 2nA, Cond 3: 15 keV 60 nA
474474.5>125 µm572.06000.160011.59002.65000.06000.02000.35004.86003.78000.010095.5500NAAZ II (II-RHY-1)2018-01-15Cond 1: 15 keV 0.5nA, Cond 2: 15 keV 2nA, Cond 3: 15 keV 60 nA
474474.5>125 µm671.59000.160010.81002.48000.0700-0.01000.41004.83003.82000.000094.1600NAAZ II (II-RHY-1)2018-01-15Cond 1: 15 keV 0.5nA, Cond 2: 15 keV 2nA, Cond 3: 15 keV 60 nA
474474.5>125 µm772.11000.150011.13002.34000.0600-0.01000.38005.28003.79000.000095.2400NAAZ II (II-RHY-1)2018-01-15Cond 1: 15 keV 0.5nA, Cond 2: 15 keV 2nA, Cond 3: 15 keV 60 nA
474474.5>125 µm871.68000.150011.43002.47000.07000.02000.32005.02003.81000.010094.9600NAAZ II (II-RHY-1)2018-01-15Cond 1: 15 keV 0.5nA, Cond 2: 15 keV 2nA, Cond 3: 15 keV 60 nA
474474.5>125 µm971.37000.150011.13002.60000.0600-0.01000.36005.17003.56000.010094.4200NAAZ II (II-RHY-1)2018-01-15Cond 1: 15 keV 0.5nA, Cond 2: 15 keV 2nA, Cond 3: 15 keV 60 nA
474474.5>125 µm1071.08000.160010.64002.36000.07000.00000.35004.87003.88000.000093.4100NAAZ II (II-RHY-1)2018-01-15Cond 1: 15 keV 0.5nA, Cond 2: 15 keV 2nA, Cond 3: 15 keV 60 nA
474474.5>125 µm1171.46000.160011.10002.41000.0700-0.01000.38004.99003.62000.010094.1900NAAZ II (II-RHY-1)2018-01-15Cond 1: 15 keV 0.5nA, Cond 2: 15 keV 2nA, Cond 3: 15 keV 60 nA
474474.5>125 µm1271.52000.150011.32002.35000.06000.01000.44004.71003.74000.010094.3100NAAZ II (II-RHY-1)2018-01-15Cond 1: 15 keV 0.5nA, Cond 2: 15 keV 2nA, Cond 3: 15 keV 60 nA
474474.5>125 µm1371.27000.150011.04002.70000.07000.03000.38004.92003.86000.010094.4300NAAZ II (II-RHY-1)2018-01-15Cond 1: 15 keV 0.5nA, Cond 2: 15 keV 2nA, Cond 3: 15 keV 60 nA
474474.525-80 µm171.45000.160011.43002.36000.0700-0.04000.36005.20003.58000.020094.5900NAAZ II (II-RHY-1)2018-01-15Cond 1: 15 keV 0.5nA, Cond 2: 15 keV 2nA, Cond 3: 15 keV 60 nA
474474.525-80 µm272.27000.170011.02002.75000.0700-0.02000.36004.98003.81000.010095.4300NAAZ II (II-RHY-1)2018-01-15Cond 1: 15 keV 0.5nA, Cond 2: 15 keV 2nA, Cond 3: 15 keV 60 nA
474474.525-80 µm371.55000.150011.78002.58000.07000.00000.35004.66003.52000.000094.6500NAAZ II (II-RHY-1)2018-01-15Cond 1: 15 keV 0.5nA, Cond 2: 15 keV 2nA, Cond 3: 15 keV 60 nA
474474.525-80 µm470.83000.170011.21002.56000.07000.01000.39005.16003.74000.000094.1500NAAZ II (II-RHY-1)2018-01-15Cond 1: 15 keV 0.5nA, Cond 2: 15 keV 2nA, Cond 3: 15 keV 60 nA
474474.525-80 µm572.18000.150011.59002.43000.09000.00000.36005.01003.48000.010095.3000NAAZ II (II-RHY-1)2018-01-15Cond 1: 15 keV 0.5nA, Cond 2: 15 keV 2nA, Cond 3: 15 keV 60 nA
474474.525-80 µm670.05000.150010.96002.42000.06000.02000.44005.44003.79000.010093.3400NAAZ II (II-RHY-1)2018-01-15Cond 1: 15 keV 0.5nA, Cond 2: 15 keV 2nA, Cond 3: 15 keV 60 nA
474474.525-80 µm771.12000.170011.65002.43000.0700-0.02000.41005.00003.69000.010094.5300NAAZ II (II-RHY-1)2018-01-15Cond 1: 15 keV 0.5nA, Cond 2: 15 keV 2nA, Cond 3: 15 keV 60 nA
474474.525-80 µm870.90000.170011.27002.59000.07000.01000.49005.40003.54000.020094.4400NAAZ II (II-RHY-1)2018-01-15Cond 1: 15 keV 0.5nA, Cond 2: 15 keV 2nA, Cond 3: 15 keV 60 nA
473473.5>125 µm172.12000.160011.49002.57000.0700-0.02000.40005.04003.6300-0.010095.4400NAAZ II (II-RHY-1)2018-01-15Cond 1: 15 keV 1nA, Cond 2: 15 keV 2nA, Cond 3: 15 keV 60 nA
473473.5>125 µm272.12000.160011.77002.48000.06000.01000.35004.83003.65000.010095.4200NAAZ II (II-RHY-1)2018-01-15Cond 1: 15 keV 1nA, Cond 2: 15 keV 2nA, Cond 3: 15 keV 60 nA
473473.5>125 µm372.56000.170011.42002.49000.0700-0.02000.42005.01003.73000.010095.8600NAAZ II (II-RHY-1)2018-01-15Cond 1: 15 keV 1nA, Cond 2: 15 keV 2nA, Cond 3: 15 keV 60 nA
473473.5>125 µm472.44000.160011.82002.58000.07000.02000.39005.05003.81000.010096.3400NAAZ II (II-RHY-1)2018-01-15Cond 1: 15 keV 1nA, Cond 2: 15 keV 2nA, Cond 3: 15 keV 60 nA
473473.5>125 µm671.43000.170011.42002.47000.0600-0.01000.39005.13003.74000.010094.8200NAAZ II (II-RHY-1)2018-01-15Cond 1: 15 keV 1nA, Cond 2: 15 keV 2nA, Cond 3: 15 keV 60 nA
473473.5>125 µm771.81000.150011.28002.40000.07000.02000.43005.00003.93000.010095.0900NAAZ II (II-RHY-1)2018-01-15Cond 1: 15 keV 1nA, Cond 2: 15 keV 2nA, Cond 3: 15 keV 60 nA
473473.5>125 µm870.95000.150011.43002.30000.0700-0.02000.38005.32003.73000.010094.3200NAAZ II (II-RHY-1)2018-01-15Cond 1: 15 keV 1nA, Cond 2: 15 keV 2nA, Cond 3: 15 keV 60 nA
473473.5>125 µm970.61000.150011.75002.50000.06000.01000.36004.97003.75000.000094.1600NAAZ II (II-RHY-1)2018-01-15Cond 1: 15 keV 1nA, Cond 2: 15 keV 2nA, Cond 3: 15 keV 60 nA
473473.5>125 µm1070.73000.160011.61002.69000.09000.00000.43005.21003.78000.010094.7000NAAZ II (II-RHY-1)2018-01-15Cond 1: 15 keV 1nA, Cond 2: 15 keV 2nA, Cond 3: 15 keV 60 nA
473473.5>125 µm1171.98000.160010.83002.62000.0500-0.02000.41005.27003.65000.010094.9600NAAZ II (II-RHY-1)2018-01-15Cond 1: 15 keV 1nA, Cond 2: 15 keV 2nA, Cond 3: 15 keV 60 nA
473473.5>125 µm1271.59000.160010.80002.53000.08000.00000.39004.94003.73000.000094.2100NAAZ II (II-RHY-1)2018-01-15Cond 1: 15 keV 1nA, Cond 2: 15 keV 2nA, Cond 3: 15 keV 60 nA
473473.5>125 µm1371.87000.160010.65002.51000.06000.00000.38004.97003.71000.010094.3300NAAZ II (II-RHY-1)2018-01-15Cond 1: 15 keV 1nA, Cond 2: 15 keV 2nA, Cond 3: 15 keV 60 nA
473473.525-80 µm172.66000.160011.13002.28000.06000.00000.32004.55004.30000.010095.4700NAAZ II (II-RHY-1)2018-01-16Cond 1: 15 keV 0.5nA, Cond 2: 15 keV 2nA, Cond 3: 15 keV 60 nA
473473.525-80 µm271.07000.160012.02002.50000.07000.00000.41005.30004.12000.000095.6500NAAZ II (II-RHY-1)2018-01-16Cond 1: 15 keV 0.5nA, Cond 2: 15 keV 2nA, Cond 3: 15 keV 60 nA
473473.525-80 µm370.77000.160012.21002.30000.08000.00000.36004.82003.96000.000094.6600NAAZ II (II-RHY-1)2018-01-16Cond 1: 15 keV 0.5nA, Cond 2: 15 keV 2nA, Cond 3: 15 keV 60 nA
473473.525-80 µm472.32000.160011.90002.48000.0700-0.01000.40005.26003.88000.010096.4500NAAZ II (II-RHY-1)2018-01-16Cond 1: 15 keV 0.5nA, Cond 2: 15 keV 2nA, Cond 3: 15 keV 60 nA
473473.525-80 µm570.91000.170011.16002.51000.07000.01000.39005.06004.08000.000094.3500NAAZ II (II-RHY-1)2018-01-16Cond 1: 15 keV 0.5nA, Cond 2: 15 keV 2nA, Cond 3: 15 keV 60 nA
473473.525-80 µm671.26000.150011.22002.41000.0700-0.01000.38004.72004.19000.010094.4000NAAZ II (II-RHY-1)2018-01-16Cond 1: 15 keV 0.5nA, Cond 2: 15 keV 2nA, Cond 3: 15 keV 60 nA
473473.525-80 µm771.40000.160011.89002.43000.06000.01000.45005.06003.95000.000095.4100NAAZ II (II-RHY-1)2018-01-16Cond 1: 15 keV 0.5nA, Cond 2: 15 keV 2nA, Cond 3: 15 keV 60 nA
473473.525-80 µm872.56000.170012.07002.42000.06000.00000.43004.97004.22000.010096.9100NAAZ II (II-RHY-1)2018-01-16Cond 1: 15 keV 0.5nA, Cond 2: 15 keV 2nA, Cond 3: 15 keV 60 nA
473473.525-80 µm970.84000.160011.96002.54000.07000.01000.39004.84004.28000.010095.1100NAAZ II (II-RHY-1)2018-01-16Cond 1: 15 keV 0.5nA, Cond 2: 15 keV 2nA, Cond 3: 15 keV 60 nA
473473.525-80 µm1072.43000.160011.73002.64000.09000.00000.43005.10004.15000.010096.7400NAAZ II (II-RHY-1)2018-01-16Cond 1: 15 keV 0.5nA, Cond 2: 15 keV 2nA, Cond 3: 15 keV 60 nA
470470.5>125 µm171.77010.161911.72152.56030.0760-0.00390.37105.44663.54500.016095.6643NAAZ II (II-RHY-1)2018-01-15Cond 1: 15 keV 0.5nA, Cond 2: 15 keV 2nA, Cond 3: 15 keV 60 nA
470470.525-80 µm171.54760.154611.48682.45050.0657-0.00150.46374.59774.61610.002995.3840NAAZ II (II-RHY-1)2018-01-16Cond 1: 15 keV 0.5nA, Cond 2: 15 keV 2nA, Cond 3: 15 keV 60 nA
470470.525-80 µm272.05980.149811.56112.54200.06730.00320.45754.69644.34570.015395.8979NAAZ II (II-RHY-1)2018-01-16Cond 1: 15 keV 0.5nA, Cond 2: 15 keV 2nA, Cond 3: 15 keV 60 nA
470470.525-80 µm372.08970.161411.81392.38140.0633-0.03600.44204.99924.54800.013896.4768NAAZ II (II-RHY-1)2018-01-16Cond 1: 15 keV 0.5nA, Cond 2: 15 keV 2nA, Cond 3: 15 keV 60 nA
470470.525-80 µm471.92170.160812.38082.72540.05670.00920.36724.73834.61230.007596.9798NAAZ II (II-RHY-1)2018-01-16Cond 1: 15 keV 0.5nA, Cond 2: 15 keV 2nA, Cond 3: 15 keV 60 nA
470470.525-80 µm572.80290.156211.50332.34610.05730.02160.45224.77024.29270.013596.4158NAAZ II (II-RHY-1)2018-01-16Cond 1: 15 keV 0.5nA, Cond 2: 15 keV 2nA, Cond 3: 15 keV 60 nA
470470.525-80 µm671.68830.141211.35332.48290.0645-0.01420.37345.19694.2238-0.001395.5089NAAZ II (II-RHY-1)2018-01-16Cond 1: 15 keV 0.5nA, Cond 2: 15 keV 2nA, Cond 3: 15 keV 60 nA
470470.525-80 µm771.97840.161011.34522.24980.06250.01380.44964.81894.13280.004895.2168NAAZ II (II-RHY-1)2018-01-16Cond 1: 15 keV 0.5nA, Cond 2: 15 keV 2nA, Cond 3: 15 keV 60 nA