Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

Steinfeldt, Reiner; Kieke, Dagmar; Bulsiewicz, Klaus (2020): Physical oceanography, CFC-11 and CFC-12 measured on water bottle samples during Maria S. Merian cruise MSM38 [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.911240

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Abstract:
Temperature, salinity and the anthropogenic tracers measured on the RV Maria S. Merian Cruise MSM38 Cadiz - St. John's 05/07 - 06/05/2014
Chief Scientist: Dagmar Kieke
Region: Subpolar North Atlantic
Keyword(s):
anthropogenic tracers; subpolar North Atlantic
Related to:
Breckenfelder, Tilia; Rhein, Monika; Roessler, Achim; Böning, Claus W; Biastoch, Arne; Behrens, Erik; Mertens, Christian (2017): Physical oceanography during Maria S. Merian cruise MSM38. PANGAEA, https://doi.org/10.1594/PANGAEA.871454
Kieke, Dagmar; Breckenfelder, Tilia; Büsing, Merle; Diekmann, Thorben; Gerken, Jan; Hauck, Dennis; Horn, Myriel; Hüsener, Matthias; Leiner, Milena; Papp, Dennis; Raschke, Michaela; Roessler, Achim; Schneehorst, Anja; Steinfeldt, Reiner; Schneider, Linn; Stendardo, Ilaria; Thewes, Daniel; Uhde, Hans-Hermann; Winkel, Jeannine (2015): NA-LINK I (Linking Past and Present in the North Atlantic) - Cruise No. MSM38 - May 07 - June 05, 2014 Cadiz (Spain) - St. John's (Canada). MARIA S. MERIAN-Berichte, DFG-Senatskommission für Ozeanographie, MSM38, 50 pp, https://doi.org/10.2312/cr_msm38
Coverage:
Median Latitude: 47.888863 * Median Longitude: -39.779702 * South-bound Latitude: 38.591667 * West-bound Longitude: -47.265000 * North-bound Latitude: 52.583333 * East-bound Longitude: -12.384500
Date/Time Start: 2014-05-08T12:03:00 * Date/Time End: 2014-06-03T20:37:00
Minimum DEPTH, water: 11.2 m * Maximum DEPTH, water: 4781.5 m
Event(s):
MSM38_343 (0) * Latitude: 38.591667 * Longitude: -12.384500 * Date/Time: 2014-05-08T12:03:00 * Elevation: -4868.0 m * Campaign: MSM38 * Basis: Maria S. Merian * Method/Device: CTD/Rosette (CTD-RO) * Comment: Test Station Calibration of MicroCATs + NKEs
MSM38_344 (1) * Latitude: 48.001000 * Longitude: -31.417833 * Date/Time: 2014-05-12T12:03:00 * Elevation: -4030.0 m * Campaign: MSM38 * Basis: Maria S. Merian * Method/Device: CTD/Rosette (CTD-RO)
MSM38_345 (2) * Latitude: 49.916667 * Longitude: -33.733167 * Date/Time: 2014-05-13T04:02:00 * Elevation: -4151.0 m * Campaign: MSM38 * Basis: Maria S. Merian * Method/Device: CTD/Rosette (CTD-RO) * Comment: Calibration of MicroCATs + NKEs
Comment:
Bottle data PI: Dagmar Kieke, Reiner Steinfeldt
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
1Event labelEventSteinfeldt, Reiner
2Date/Time of eventDate/TimeSteinfeldt, Reiner
3Latitude of eventLatitudeSteinfeldt, Reiner
4Longitude of eventLongitudeSteinfeldt, Reiner
5Elevation of eventElevationmSteinfeldt, Reiner
6Station labelStationSteinfeldt, Reiner
7ProfileProfileSteinfeldt, Reiner
8Bottle numberBottleSteinfeldt, Reiner
9Time in daysTimedaysSteinfeldt, ReinerSince start of the year
10DEPTH, waterDepth watermSteinfeldt, ReinerGeocode
11Pressure, waterPressdbarSteinfeldt, ReinerCTD, SEA-BIRD SBE 9 plus, SBE 11 plus deck unitAccuracy: <1 dbar
12Temperature, waterTemp°CSteinfeldt, ReinerCTD, SEA-BIRD SBE 9 plus, SBE 11 plus deck unitAccuracy: 0.001 °C
13Temperature, water, potentialTpot°CSteinfeldt, ReinerCalculated
14SalinitySalSteinfeldt, ReinerCTD, SEA-BIRD SBE 9 plus, SBE 11 plus deck unitAccuracy: 0.002
15Density, sigma-theta (0)Sigma-thetakg/m3Steinfeldt, ReinerCalculated
16OxygenO2µmol/kgSteinfeldt, ReinerOxygen, Winkler (Culberson, 1991, WOCE Report 68/91)Bottle; Precision: 1 µmol/kg
17OxygenO2µmol/kgSteinfeldt, ReinerOxygen sensor, SBE 43CTD; Accuracy: 3.0 µmol/kg
18Freon-11 (trichorofluoromethane)CFC-11pmol/kgBulsiewicz, KlausCapillary-chromatographic system with electron capture detectorFlame sealed samples; Calibration scale: SIO-98; Accuracy: 2.3 %
19Freon-12 (dichlorodifluoromethane)CFC-12pmol/kgBulsiewicz, KlausCapillary-chromatographic system with electron capture detectorFlame sealed samples; Calibration scale: SIO-98; Accuracy: 2 %
Size:
26513 data points

Download Data

Download dataset as tab-delimited text — use the following character encoding:

View dataset as HTML (shows only first 2000 rows)