Witthuhn, Jonas; Deneke, Hartwig; Macke, Andreas (2020): Shipborne rotating shadowband radiometer data of spectral irradiance components and aerosol optical depth during POLARSTERN cruise PS113 (ANT-XXXIII/4) [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.910531, In: Witthuhn, J et al. (2020): Shipborne rotating shadowband radiometer data of spectral irradiance components and aerosol optical depth during Polarstern cruises PS83, PS95, PS98, PS102 and PS113 [dataset publication series]. PANGAEA, https://doi.org/10.1594/PANGAEA.910535

Always quote citation above when using data! You can download the citation in several formats below.

Published: 2020-01-08DOI registered: 2020-04-04

RIS CitationBibTeX Citation ShareShow MapGoogle Earth

Related to:
Witthuhn, Jonas; Deneke, Hartwig; Macke, Andreas; Bernhard, Germar (2017): Algorithms and uncertainties for the determination of multispectral irradiance components and aerosol optical depth from a shipborne rotating shadowband radiometer. Atmospheric Measurement Techniques, 10(2), 709-730, https://doi.org/10.5194/amt-10-709-2017
Witthuhn, Jonas; Hünerbein, Anja; Deneke, Hartwig (2020): Evaluation of satellite-based aerosol datasets and the CAMS reanalysis over the ocean utilizing shipborne reference observations. Atmospheric Measurement Techniques, 13(3), 1387-1412, https://doi.org/10.5194/amt-13-1387-2020
Coverage:
Median Latitude: 5.165358 * Median Longitude: -25.324158 * South-bound Latitude: -45.315800 * West-bound Longitude: -57.316470 * North-bound Latitude: 50.442440 * East-bound Longitude: 0.744200
Date/Time Start: 2018-05-11T10:33:16 * Date/Time End: 2018-06-09T13:40:20
Minimum ALTITUDE: 20 m * Maximum ALTITUDE: 20 m
Event(s):
PS113-track * Latitude Start: -53.144700 * Longitude Start: -70.909100 * Latitude End: 53.567500 * Longitude End: 8.554800 * Date/Time Start: 2018-05-08T14:15:00 * Date/Time End: 2018-06-10T22:30:00 * Campaign: PS113 (ANT-XXXIII/4) * Basis: Polarstern * Method/Device: Underway cruise track measurements (CT)
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
1DATE/TIMEDate/TimeDeneke, HartwigGeocode
2LATITUDELatitudeDeneke, HartwigGeocode
3LONGITUDELongitudeDeneke, HartwigGeocode
4ALTITUDEAltitudemDeneke, HartwigGeocode
5Spectral irradiance, downward at 305 nmEd_305W/m2/nmDeneke, HartwigGround-Based UV-Visble radiometer with BioSHADE accessory, GUVis-3511, BSI Inc.
6Spectral irradiance, downward at 340 nmEd_340W/m2/nmDeneke, HartwigGround-Based UV-Visble radiometer with BioSHADE accessory, GUVis-3511, BSI Inc.
7Spectral irradiance, downward at 380 nmEd_380W/m2/nmDeneke, HartwigGround-Based UV-Visble radiometer with BioSHADE accessory, GUVis-3511, BSI Inc.
8Spectral irradiance, downward at 412 nmEd_412W/m2/nmDeneke, HartwigGround-Based UV-Visble radiometer with BioSHADE accessory, GUVis-3511, BSI Inc.
9Spectral irradiance, downward at 443 nmEd_443W/m2/nmDeneke, HartwigGround-Based UV-Visble radiometer with BioSHADE accessory, GUVis-3511, BSI Inc.
10Spectral irradiance, downward at 510 nmEd_510W/m2/nmDeneke, HartwigGround-Based UV-Visble radiometer with BioSHADE accessory, GUVis-3511, BSI Inc.
11Spectral irradiance, downward at 610 nmEd_610W/m2/nmDeneke, HartwigGround-Based UV-Visble radiometer with BioSHADE accessory, GUVis-3511, BSI Inc.
12Spectral irradiance, downward at 625 nmEd_625W/m2/nmDeneke, HartwigGround-Based UV-Visble radiometer with BioSHADE accessory, GUVis-3511, BSI Inc.
13Spectral irradiance, downward at 665 nmEd_665W/m2/nmDeneke, HartwigGround-Based UV-Visble radiometer with BioSHADE accessory, GUVis-3511, BSI Inc.
14Spectral irradiance, downward at 694 nmEd_694W/m2/nmDeneke, HartwigGround-Based UV-Visble radiometer with BioSHADE accessory, GUVis-3511, BSI Inc.
15Spectral irradiance, downward at 750 nmEd_750W/m2/nmDeneke, HartwigGround-Based UV-Visble radiometer with BioSHADE accessory, GUVis-3511, BSI Inc.
16Spectral irradiance, downward at 765 nmEd_765W/m2/nmDeneke, HartwigGround-Based UV-Visble radiometer with BioSHADE accessory, GUVis-3511, BSI Inc.
17Spectral irradiance, downward at 875 nmEd_875W/m2/nmDeneke, HartwigGround-Based UV-Visble radiometer with BioSHADE accessory, GUVis-3511, BSI Inc.
18Spectral irradiance, downward at 940 nmEd_940W/m2/nmDeneke, HartwigGround-Based UV-Visble radiometer with BioSHADE accessory, GUVis-3511, BSI Inc.
19Spectral irradiance, downward at 1020 nmEd_1020W/m2/nmDeneke, HartwigGround-Based UV-Visble radiometer with BioSHADE accessory, GUVis-3511, BSI Inc.
20Spectral irradiance, downward at 1245 nmEd_1245W/m2/nmDeneke, HartwigGround-Based UV-Visble radiometer with BioSHADE accessory, GUVis-3511, BSI Inc.
21Spectral irradiance, downward at 1550 nmEd_1550W/m2/nmDeneke, HartwigGround-Based UV-Visble radiometer with BioSHADE accessory, GUVis-3511, BSI Inc.
22Spectral irradiance, downward at 1640 nmEd_1640W/m2/nmDeneke, HartwigGround-Based UV-Visble radiometer with BioSHADE accessory, GUVis-3511, BSI Inc.
23Short-wave downward (GLOBAL) radiationSWDW/m2Deneke, HartwigGround-Based UV-Visble radiometer with BioSHADE accessory, GUVis-3511, BSI Inc.
24Spectral irradiance, incident at 305 nmEi_305W/m2/nmDeneke, HartwigGround-Based UV-Visble radiometer with BioSHADE accessory, GUVis-3511, BSI Inc.
25Spectral irradiance, incident at 340 nmEi_340W/m2/nmDeneke, HartwigGround-Based UV-Visble radiometer with BioSHADE accessory, GUVis-3511, BSI Inc.
26Spectral irradiance, incident at 380 nmEi_380W/m2/nmDeneke, HartwigGround-Based UV-Visble radiometer with BioSHADE accessory, GUVis-3511, BSI Inc.
27Spectral irradiance, incident at 412 nmEi_412W/m2/nmDeneke, HartwigGround-Based UV-Visble radiometer with BioSHADE accessory, GUVis-3511, BSI Inc.
28Spectral irradiance, incident at 443 nmEi_443W/m2/nmDeneke, HartwigGround-Based UV-Visble radiometer with BioSHADE accessory, GUVis-3511, BSI Inc.
29Spectral irradiance, incident at 510 nmEi_510W/m2/nmDeneke, HartwigGround-Based UV-Visble radiometer with BioSHADE accessory, GUVis-3511, BSI Inc.
30Spectral irradiance, incident at 610 nmEi_610W/m2/nmDeneke, HartwigGround-Based UV-Visble radiometer with BioSHADE accessory, GUVis-3511, BSI Inc.
31Spectral irradiance, incident at 625 nmEi_625W/m2/nmDeneke, HartwigGround-Based UV-Visble radiometer with BioSHADE accessory, GUVis-3511, BSI Inc.
32Spectral irradiance, incident at 665 nmEi_665W/m2/nmDeneke, HartwigGround-Based UV-Visble radiometer with BioSHADE accessory, GUVis-3511, BSI Inc.
33Spectral irradiance, incident at 694 nmEi_694W/m2/nmDeneke, HartwigGround-Based UV-Visble radiometer with BioSHADE accessory, GUVis-3511, BSI Inc.
34Spectral irradiance, incident at 750 nmEi_750W/m2/nmDeneke, HartwigGround-Based UV-Visble radiometer with BioSHADE accessory, GUVis-3511, BSI Inc.
35Spectral irradiance, incident at 765 nmEi_765W/m2/nmDeneke, HartwigGround-Based UV-Visble radiometer with BioSHADE accessory, GUVis-3511, BSI Inc.
36Spectral irradiance, incident at 875 nmEi_875W/m2/nmDeneke, HartwigGround-Based UV-Visble radiometer with BioSHADE accessory, GUVis-3511, BSI Inc.
37Spectral irradiance, incident at 940 nmEi_940W/m2/nmDeneke, HartwigGround-Based UV-Visble radiometer with BioSHADE accessory, GUVis-3511, BSI Inc.
38Spectral irradiance, incident at 1020 nmEi_1020W/m2/nmDeneke, HartwigGround-Based UV-Visble radiometer with BioSHADE accessory, GUVis-3511, BSI Inc.
39Spectral irradiance, incident at 1245 nmEi_1245W/m2/nmDeneke, HartwigGround-Based UV-Visble radiometer with BioSHADE accessory, GUVis-3511, BSI Inc.
40Spectral irradiance, incident at 1550 nmEi_1550W/m2/nmDeneke, HartwigGround-Based UV-Visble radiometer with BioSHADE accessory, GUVis-3511, BSI Inc.
41Spectral irradiance, incident at 1640 nmEi_1640W/m2/nmDeneke, HartwigGround-Based UV-Visble radiometer with BioSHADE accessory, GUVis-3511, BSI Inc.
42Direct radiationDIRW/m2Deneke, HartwigGround-Based UV-Visble radiometer with BioSHADE accessory, GUVis-3511, BSI Inc.
43Spectral irradiance, downward - incident at 305 nmEd-Ei_305W/m2/nmDeneke, HartwigGround-Based UV-Visble radiometer with BioSHADE accessory, GUVis-3511, BSI Inc.
44Spectral irradiance, downward - incident at 340 nmEd-Ei_340W/m2/nmDeneke, HartwigGround-Based UV-Visble radiometer with BioSHADE accessory, GUVis-3511, BSI Inc.
45Spectral irradiance, downward - incident at 380 nmEd-Ei_380W/m2/nmDeneke, HartwigGround-Based UV-Visble radiometer with BioSHADE accessory, GUVis-3511, BSI Inc.
46Spectral irradiance, downward - incident at 412 nmEd-Ei_412W/m2/nmDeneke, HartwigGround-Based UV-Visble radiometer with BioSHADE accessory, GUVis-3511, BSI Inc.
47Spectral irradiance, downward - incident at 443 nmEd-Ei_443W/m2/nmDeneke, HartwigGround-Based UV-Visble radiometer with BioSHADE accessory, GUVis-3511, BSI Inc.
48Spectral irradiance, downward - incident at 510 nmEd-Ei_510W/m2/nmDeneke, HartwigGround-Based UV-Visble radiometer with BioSHADE accessory, GUVis-3511, BSI Inc.
49Spectral irradiance, downward - incident at 610 nmEd-Ei_610W/m2/nmDeneke, HartwigGround-Based UV-Visble radiometer with BioSHADE accessory, GUVis-3511, BSI Inc.
50Spectral irradiance, downward - incident at 625 nmEd-Ei_625W/m2/nmDeneke, HartwigGround-Based UV-Visble radiometer with BioSHADE accessory, GUVis-3511, BSI Inc.
51Spectral irradiance, downward - incident at 665 nmEd-Ei_665W/m2/nmDeneke, HartwigGround-Based UV-Visble radiometer with BioSHADE accessory, GUVis-3511, BSI Inc.
52Spectral irradiance, downward - incident at 694 nmEd-Ei_694W/m2/nmDeneke, HartwigGround-Based UV-Visble radiometer with BioSHADE accessory, GUVis-3511, BSI Inc.
53Spectral irradiance, downward - incident at 750 nmEd-Ei_750W/m2/nmDeneke, HartwigGround-Based UV-Visble radiometer with BioSHADE accessory, GUVis-3511, BSI Inc.
54Spectral irradiance, downward - incident at 765 nmEd-Ei_765W/m2/nmDeneke, HartwigGround-Based UV-Visble radiometer with BioSHADE accessory, GUVis-3511, BSI Inc.
55Spectral irradiance, downward - incident at 875 nmEd-Ei_875W/m2/nmDeneke, HartwigGround-Based UV-Visble radiometer with BioSHADE accessory, GUVis-3511, BSI Inc.
56Spectral irradiance, downward - incident at 940 nmEd-Ei_940W/m2/nmDeneke, HartwigGround-Based UV-Visble radiometer with BioSHADE accessory, GUVis-3511, BSI Inc.
57Spectral irradiance, downward - incident at 1020 nmEd-Ei_1020W/m2/nmDeneke, HartwigGround-Based UV-Visble radiometer with BioSHADE accessory, GUVis-3511, BSI Inc.
58Spectral irradiance, downward - incident at 1245 nmEd-Ei_1245W/m2/nmDeneke, HartwigGround-Based UV-Visble radiometer with BioSHADE accessory, GUVis-3511, BSI Inc.
59Spectral irradiance, downward - incident at 1550 nmEd-Ei_1550W/m2/nmDeneke, HartwigGround-Based UV-Visble radiometer with BioSHADE accessory, GUVis-3511, BSI Inc.
60Spectral irradiance, downward - incident at 1640 nmEd-Ei_1640W/m2/nmDeneke, HartwigGround-Based UV-Visble radiometer with BioSHADE accessory, GUVis-3511, BSI Inc.
61Diffuse radiationDIFW/m2Deneke, HartwigGround-Based UV-Visble radiometer with BioSHADE accessory, GUVis-3511, BSI Inc.
62Aerosol optical thickness at 340 nmAOT_340Deneke, HartwigGround-Based UV-Visble radiometer with BioSHADE accessory, GUVis-3511, BSI Inc.
63Aerosol optical thickness at 380 nmAOT_380Deneke, HartwigGround-Based UV-Visble radiometer with BioSHADE accessory, GUVis-3511, BSI Inc.
64Aerosol optical thickness at 412 nmAOT_412Deneke, HartwigGround-Based UV-Visble radiometer with BioSHADE accessory, GUVis-3511, BSI Inc.
65Aerosol optical thickness at 443 nmAOT_443Deneke, HartwigGround-Based UV-Visble radiometer with BioSHADE accessory, GUVis-3511, BSI Inc.
66Aerosol optical thickness at 510 nmAOT_510Deneke, HartwigGround-Based UV-Visble radiometer with BioSHADE accessory, GUVis-3511, BSI Inc.
67Aerosol optical thickness at 610 nmAOT_610Deneke, HartwigGround-Based UV-Visble radiometer with BioSHADE accessory, GUVis-3511, BSI Inc.
68Aerosol optical thickness at 625 nmAOT_625Deneke, HartwigGround-Based UV-Visble radiometer with BioSHADE accessory, GUVis-3511, BSI Inc.
69Aerosol optical thickness at 665 nmAOT_665Deneke, HartwigGround-Based UV-Visble radiometer with BioSHADE accessory, GUVis-3511, BSI Inc.
70Aerosol optical thickness at 694 nmAOT_694Deneke, HartwigGround-Based UV-Visble radiometer with BioSHADE accessory, GUVis-3511, BSI Inc.
71Aerosol optical thickness at 750 nmAOT_750Deneke, HartwigGround-Based UV-Visble radiometer with BioSHADE accessory, GUVis-3511, BSI Inc.
72Aerosol optical thickness at 765 nmAOT_765Deneke, HartwigGround-Based UV-Visble radiometer with BioSHADE accessory, GUVis-3511, BSI Inc.
73Aerosol optical thickness at 875 nmAOT_875Deneke, HartwigGround-Based UV-Visble radiometer with BioSHADE accessory, GUVis-3511, BSI Inc.
74Aerosol optical thickness at 940 nmAOT_940Deneke, HartwigGround-Based UV-Visble radiometer with BioSHADE accessory, GUVis-3511, BSI Inc.
75Aerosol optical thickness at 1020 nmAOT_1020Deneke, HartwigGround-Based UV-Visble radiometer with BioSHADE accessory, GUVis-3511, BSI Inc.
76Aerosol optical thickness at 1245 nmAOT_1245Deneke, HartwigGround-Based UV-Visble radiometer with BioSHADE accessory, GUVis-3511, BSI Inc.
77Aerosol optical thickness at 1550 nmAOT_1550Deneke, HartwigGround-Based UV-Visble radiometer with BioSHADE accessory, GUVis-3511, BSI Inc.
78Aerosol optical thickness at 1640 nmAOT_1640Deneke, HartwigGround-Based UV-Visble radiometer with BioSHADE accessory, GUVis-3511, BSI Inc.
Size: