Antoine, Pierre (2019): High resolution (5 cm) continuous record of grain size and magnetic susceptibility of the 20 m thick loess palaeosol sequence of Harletz, Bulgaria [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.905216, In: Antoine, P (2019): High resolution continuous record of grain size, magnetic susceptibility, color (a*) of the 20 m thick loess palaeosol sequence of Harletz, Bulgaria [dataset publication series]. PANGAEA, https://doi.org/10.1594/PANGAEA.905217
Always quote citation above when using data! You can download the citation in several formats below.
Related to:
Antoine, Pierre; Lagroix, France; Jordanova, Diana; Jordanova, Neli; Lomax, Johanna; Fuchs, Markus; Debret, Maxime; Rousseau, Denis-Didier; Hatte, Christine; Gauthier, Caroline; Moine, Olivier; Taylor, Samuel N; Till, Jessica L; Coutard, Sylvie (2019): A remarkable Late Saalian (MIS 6) loess (dust) accumulation in the Lower Danube at Harletz (Bulgaria). Quaternary Science Reviews, 207, 80-100, https://doi.org/10.1016/j.quascirev.2019.01.005
Coverage:
Latitude: 43.697990 * Longitude: 23.828410
Minimum DEPTH, sediment/rock: 0.03 m * Maximum DEPTH, sediment/rock: 19.98 m
Event(s):
Parameter(s):
# | Name | Short Name | Unit | Principal Investigator | Method/Device | Comment |
---|---|---|---|---|---|---|
1 | DEPTH, sediment/rock | Depth sed | m | Antoine, Pierre | Geocode – center of the sample | |
2 | Size fraction < 0.006 mm | <6 µm | % | Antoine, Pierre | Beckman Coulter Laser diffraction particle size analyzer LS 230 | |
3 | Size fraction 0.020-0.006 mm | 20-6 µm | % | Antoine, Pierre | Beckman Coulter Laser diffraction particle size analyzer LS 230 | |
4 | Size fraction 0.061-0.020 mm | 61-20 µm | % | Antoine, Pierre | Beckman Coulter Laser diffraction particle size analyzer LS 230 | |
5 | Size fraction 0.160-0.061 mm | 160-61 µm | % | Antoine, Pierre | Beckman Coulter Laser diffraction particle size analyzer LS 230 | |
6 | Size fraction > 0.160 mm | >160 µm | % | Antoine, Pierre | Grain size, sieving | percentage of the initial sample mass (before sieving) |
7 | Size fraction < 0.0046 mm | <4.6 µm | % | Antoine, Pierre | Beckman Coulter Laser diffraction particle size analyzer LS 230 | |
8 | Size fraction 0.026-0.0046 mm | 26-4.6 µm | % | Antoine, Pierre | Beckman Coulter Laser diffraction particle size analyzer LS 230 | |
9 | Size fraction 0.052-0.026 mm | 52-26 µm | % | Antoine, Pierre | Beckman Coulter Laser diffraction particle size analyzer LS 230 | |
10 | Size fraction 0.160-0.052 mm | 160-52 µm | % | Antoine, Pierre | Beckman Coulter Laser diffraction particle size analyzer LS 230 | |
11 | Size fraction < 0.008 mm, clay | <8 µm | % | Antoine, Pierre | Beckman Coulter Laser diffraction particle size analyzer LS 230 | |
12 | Size fraction 0.160-0.080 mm | 16-8 µm | % | Antoine, Pierre | Beckman Coulter Laser diffraction particle size analyzer LS 230 | |
13 | Size fraction 0.044-0.016 mm | 44-16 µm | % | Antoine, Pierre | Beckman Coulter Laser diffraction particle size analyzer LS 230 | |
14 | Size fraction 0.063-0.044 mm | 63-44 µm | % | Antoine, Pierre | Beckman Coulter Laser diffraction particle size analyzer LS 230 | |
15 | Size fraction 0.160-0.063 mm | 160-63 µm | % | Antoine, Pierre | Beckman Coulter Laser diffraction particle size analyzer LS 230 | |
16 | Susceptibility, frequency dependence | chi_fd | 10-9 m3/kg | Antoine, Pierre | Bartington MS2B bulk sensor | ΔχFD: frequencies 465 Hz and 4650 Hz |
17 | Susceptibility, specific | chi | 10-9 m3/kg | Antoine, Pierre | Bartington MS2B bulk sensor | mass specific magnetic susceptibility (χ_BULK) |
18 | Carbon, organic, total | TOC | % | Antoine, Pierre | Element analyser, Thermo Finnigan flash EA 1112 | |
19 | Calcium carbonate | CaCO3 | % | Antoine, Pierre | Element analyser, Thermo Finnigan flash EA 1112 |
License:
Creative Commons Attribution 4.0 International (CC-BY-4.0)
Size:
7211 data points
Download Data
View dataset as HTML (shows only first 2000 rows)