Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

Oliveira, Ana (2019): Extreme Temperature ET-SCI Indices - Annual time-series - Naples, Italy [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.898884, In: Oliveira, A (2019): Extreme Temperature Indices Time Series - Yearly summary ET-SCI Indices calculated from E-OBS v17.e dataset, with ClimPACT2 software at 5 Southern European Cities [dataset publication series]. PANGAEA, https://doi.org/10.1594/PANGAEA.898885

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Keyword(s):
climPACT2; coldwave indices; correlation; E-OBS; ET-SCI; heatwave indices; Southern European cities; trends
Further details:
Alexander, Lisa V; Herold, Nicholas (2016): ClimPACT2: Indices and software. https://github.com/ARCCSS-extremes/climpact2, hdl:10013/epic.94f52968-eeed-4766-9285-5c3466c98932
Cornes, Richard C; van der Schrier, Gerard; van den Besselaar, Else J M; Jones, Philip D (2018): An Ensemble Version of the E-OBS Temperature and Precipitation Data Sets. Journal of Geophysical Research: Atmospheres, 123(17), 9391-9409, https://doi.org/10.1029/2017JD028200
Coverage:
Latitude: 40.950000 * Longitude: 14.250000
Date/Time Start: 1950-01-01T00:00:00 * Date/Time End: 2018-09-30T00:00:00
Event(s):
EOB-S_Naples_Italy (Naples/Capodichino) * Latitude: 40.950000 * Longitude: 14.250000 * Location: Italy * Method/Device: Multiple investigations (MULT) * Comment: ECAD&D Reference Station ID: 2093
Comment:
We acknowledge the E-OBS dataset from the EU-FP6 project UERRA (http://www.uerra.eu) and the Copernicus Climate Change Service, and the data providers in the ECA&D project (https://www.ecad.eu).
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
DATE/TIMEDate/TimeOliveira, AnaGeocode – Year
Summer daysSUdaysOliveira, AnaIndices calculated from E-OBS v17.e dataset, with ClimPACT2 softwareNPL_SU
Tropical nightsTRdaysOliveira, AnaIndices calculated from E-OBS v17.e dataset, with ClimPACT2 softwareNPL_TR
Temperature, air, annual maximum, daily maximumTXx°COliveira, AnaIndices calculated from E-OBS v17.e dataset, with ClimPACT2 softwareNPL_TXx
Warm spell duration indicatorWSDIdaysOliveira, AnaIndices calculated from E-OBS v17.e dataset, with ClimPACT2 softwareNPL_WSDI
Hot daysTX90p%Oliveira, AnaIndices calculated from E-OBS v17.e dataset, with ClimPACT2 softwareNPL_TX90p
Warm nightsTN90p%Oliveira, AnaIndices calculated from E-OBS v17.e dataset, with ClimPACT2 softwareNPL_TN90p
Heatwave numberHWN#Oliveira, AnaIndices calculated from E-OBS v17.e dataset, with ClimPACT2 softwareNPL_HWN
Heatwave frequencyHWFdaysOliveira, AnaIndices calculated from E-OBS v17.e dataset, with ClimPACT2 softwareNPL_HWF
10 Heatwave durationHWDdaysOliveira, AnaIndices calculated from E-OBS v17.e dataset, with ClimPACT2 softwareNPL_HWD
11 Heatwave magnitudeHWM°C2Oliveira, AnaIndices calculated from E-OBS v17.e dataset, with ClimPACT2 softwareNPL_HWM
12 Heatwave amplitudeHWA°C2Oliveira, AnaIndices calculated from E-OBS v17.e dataset, with ClimPACT2 softwareNPL_HWA
13 Cooling degree daysCDDOliveira, AnaIndices calculated from E-OBS v17.e dataset, with ClimPACT2 softwareNPL_CDD
14 Temperature, air, annual minimum, daily minimumTNn°COliveira, AnaIndices calculated from E-OBS v17.e dataset, with ClimPACT2 softwareNPL_TNn
15 Cold spell duration indicatorCSDIdaysOliveira, AnaIndices calculated from E-OBS v17.e dataset, with ClimPACT2 softwareNPL_CSDI
16 Amount of cool daysTX10p%Oliveira, AnaIndices calculated from E-OBS v17.e dataset, with ClimPACT2 softwareNPL_TX10p
17 Amount of cold nightsTN10p%Oliveira, AnaIndices calculated from E-OBS v17.e dataset, with ClimPACT2 softwareNPL_TN10p
18 Coldwave numberCWN#Oliveira, AnaIndices calculated from E-OBS v17.e dataset, with ClimPACT2 softwareNPL_CWN
19 Coldwave frequencyCWFdaysOliveira, AnaIndices calculated from E-OBS v17.e dataset, with ClimPACT2 softwareNPL_CWF
20 Coldwave durationCWDdaysOliveira, AnaIndices calculated from E-OBS v17.e dataset, with ClimPACT2 softwareNPL_CWD
21 Coldwave magnitudeCWM°C2Oliveira, AnaIndices calculated from E-OBS v17.e dataset, with ClimPACT2 softwareNPL_CWM
22 Coldwave amplitudeCWA°C2Oliveira, AnaIndices calculated from E-OBS v17.e dataset, with ClimPACT2 softwareNPL_CWA
23 Heating degree daysHDDOliveira, AnaIndices calculated from E-OBS v17.e dataset, with ClimPACT2 softwareNPL_HDD
Size:
1440 data points

Data

Download dataset as tab-delimited text — use the following character encoding:


Date/Time

SU [days]

TR [days]

TXx [°C]

WSDI [days]

TX90p [%]

TN90p [%]

HWN [#]

HWF [days]
10 
HWD [days]
11 
HWM [°C2]
12 
HWA [°C2]
13 
CDD
14 
TNn [°C]
15 
CSDI [days]
16 
TX10p [%]
17 
TN10p [%]
18 
CWN [#]
19 
CWF [days]
20 
CWD [days]
21 
CWM [°C2]
22 
CWA [°C2]
23 
HDD
19501178735.91911.254.2762164.315.0398.32.505.20.000609.6
19511203233.9014.025.2428101.13.8253.10.606.80.800653.3
19521225736.9816.739.9552185.222.2354.20.307.93.82107-2.9-5.6856.9
19531213834.969.624.7422133.318.4249.3-1.4010.10.821512-4.0-14.3861.1
19541041633.505.521.11332.84.2154.5-2.9015.33.04185-5.8-31.4886.5
19551012032.407.928.81444.710.3160.61.109.31.600645.7
19561123137.907.421.041344.520.1217.4-3.61216.79.833724-10.2-46.11053.4
1957102836.276.611.021064.48.5119.2-2.1010.78.8274-16.9-43.4884.2
1958120836.707.712.100123.4-2.0011.27.42107-2.6-5.8912.7
195994232.806.87.900111.1-1.509.99.0274-4.7-11.1851.2
1960118333.009.011.215512.720.181.9-1.3011.25.5274-2.5-5.9825.5
1961117234.8014.77.400130.6-3.076.010.42128-14.3-58.6861.1
1962110535.5013.09.541881.68.0210.0-2.91412.913.53218-12.0-38.51043.3
1963103434.809.89.200162.0-4.11811.513.132813-18.5-60.2971.5
1964111333.606.36.51332.93.8125.2-2.707.711.92116-3.5-13.8948.3
196594535.706.47.21333.15.3116.6-3.0613.616.712121-8.0-16.11003.1
1966120133.805.910.21445.08.987.9-3.4011.411.56226-6.4-47.4989.1
196798734.509.49.400156.3-2.8712.811.032514-7.4-20.7955.5
1968105634.609.58.32746.218.384.8-4.11212.214.52179-12.0-45.2915.5
1969101133.106.99.00088.5-3.81213.510.3285-6.3-13.3941.4
1970108334.307.49.400127.0-0.809.513.2274-2.7-7.9928.5
19711031036.006.07.300163.5-3.41413.413.411010-12.2-24.51016.1
197291434.807.87.61331.92.692.4-0.1716.614.600818.5
1973132734.807.37.731049.941.5177.2-2.81211.613.12137-13.0-24.51104.2
197499835.205.04.200153.6-0.7014.811.0133-1.9-3.11042.7
1975108735.605.35.921065.116.0145.0-1.709.87.0274-5.4-12.1996.7
197699832.202.47.80090.5-2.3015.09.73114-5.6-15.9988.7
1977108433.307.811.531144.712.3119.1-1.109.55.6144-7.6-11.8802.3
197893433.806.37.91332.94.188.4-1.1014.312.13104-1.1-3.5968.9
1979109934.406.411.31554.48.1122.3-2.8012.07.62128-13.4-26.4928.7
19801011134.502.13.70096.9-3.0618.316.53197-8.5-22.81144.4
1981118939.609.812.22958.420.7141.2-4.71312.514.55278-4.6-32.91047.3
19821263636.809.816.152364.322.1294.0-0.906.26.93135-3.7-7.5931.4
19831202038.509.212.3317132.36.2215.2-1.308.58.54166-3.9-8.01001.7
198493835.305.07.000105.2-1.8014.14.43158-6.5-18.7940.3
19851422135.5614.99.9523101.810.5229.3-4.307.28.022014-13.5-42.8973.4
19861432736.51726.316.5540172.25.4278.1-3.674.97.23178-12.9-41.4884.2
19871253338.12525.020.1547174.724.6336.8-4.4116.611.13209-8.9-35.9930.7
19881303037.72223.514.2537107.052.3305.1-2.805.110.13156-7.7-32.5955.8
19891263135.92425.112.7323132.37.3246.4-0.501.511.0133-1.3-2.0798.3
19901273434.62421.529.331474.214.7261.80.402.71.000737.5
19911184333.308.822.542171.23.5276.9-1.369.97.74258-4.0-14.4982.4
19921324435.7618.331.4438184.514.5308.1-1.005.21.1144-8.9-14.0766.8
19931363636.91419.527.4635114.218.1290.7-2.707.43.03135-8.8-34.0831.7
19941276436.01925.238.4979333.316.9426.0-0.503.82.5144-3.0-4.3685.4
19951234735.41215.328.5323161.76.3275.90.607.13.6285-2.9-7.9753.0
19961104236.02415.830.6317103.914.0246.0-1.106.33.3263-9.9-27.3700.8
19971474135.51923.627.7434125.125.4302.91.004.12.700678.8
19981175136.73621.929.9756213.724.6347.6-1.906.85.5263-5.1-14.2805.5
19991384638.02421.131.5861163.419.7314.1-1.704.13.32116-7.5-28.4809.1
20001455135.56032.041.5566233.48.6343.7-0.703.31.9144-4.6-8.1598.6
20011425635.83824.946.673995.014.8313.5-2.106.33.62139-3.7-16.1631.4
20021115935.83119.734.2532155.428.8291.6-2.208.22.72137-3.8-9.6661.9
20031378136.95724.740.8490318.540.6462.4-1.807.13.321410-2.4-8.0867.2
20041163934.91710.734.42843.08.3240.7-2.507.11.9155-14.9-27.0780.2
20051245435.2911.837.8643151.89.5300.5-2.109.03.352814-3.1-14.8954.4
20061276936.73021.445.5649168.238.9404.8-2.506.00.8155-4.2-9.9711.0
20071146736.94721.643.8650135.224.4353.11.506.30.500585.5
20081017234.7711.548.1652244.015.6378.81.104.60.000608.4
20091347735.31815.949.9984313.117.0419.8-0.105.22.5177-2.4-6.8690.1
20101106536.71210.247.0344245.614.0341.1-0.507.40.5144-7.9-16.1690.9
20111407435.83823.654.5773333.220.8412.20.004.70.800582.0
20121269236.22422.157.1790353.420.8503.1-1.704.61.6296-4.3-15.7648.8
20131157436.91715.355.1860223.124.5355.5-1.504.40.5133-3.4-6.9621.2
20141257034.23219.557.852782.712.7276.50.005.50.3133-20.5-33.1440.3
20151289235.52520.167.8689455.327.1493.6-0.402.80.3122-21.5-33.1499.7
201611110034.32016.782.2957142.311.1387.05.003.80.000299.9
20171228538.12517.955.4875203.919.6470.21.303.00.3144-6.2-7.4567.0
20181085201.69.1133-12.4-21.7