Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

Liu, Yangyang; Boss, Emmanuel; Chase, Alison P; Xi, Hongyan; Zhang, Xiaodong; Röttgers, Rüdiger; Pan, Yanqun; Bracher, Astrid (2019): Spectral particulate attenuation coefficients and their standard deviation derived from underway AC-S measurements during POLARSTERN cruise PS93.2 [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.898120, In supplement to: Liu, Y et al. (2019): Retrieval of phytoplankton pigments from underway spectrophotometry in the Fram Strait. Remote Sensing, 11(3), 318, https://doi.org/10.3390/rs11030318

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Funding:
German Research Foundation (DFG), grant/award no. 268020496: TRR 172: ArctiC Amplification: Climate Relevant Atmospheric and SurfaCe Processes, and Feedback Mechanisms
Coverage:
Median Latitude: 78.819518 * Median Longitude: 4.421067 * South-bound Latitude: 73.476667 * West-bound Longitude: -3.073833 * North-bound Latitude: 80.004667 * East-bound Longitude: 14.183333
Date/Time Start: 2015-07-22T22:18:00 * Date/Time End: 2015-08-12T05:50:00
Minimum DEPTH, water: 11 m * Maximum DEPTH, water: 11 m
Event(s):
PS93.2-track * Latitude Start: 69.678000 * Longitude Start: 18.989800 * Latitude End: 69.678000 * Longitude End: 18.989810 * Date/Time Start: 2015-07-20T00:00:00 * Date/Time End: 2015-08-14T00:00:00 * Campaign: PS93.2 (ARK-XXIX/2.2) * Basis: Polarstern * Method/Device: Underway cruise track measurements (CT)
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
1DEPTH, waterDepth watermLiu, YangyangGeocode
2DATE/TIMEDate/TimeLiu, YangyangGeocode – UTC
3LATITUDELatitudeLiu, YangyangGeocode
4LONGITUDELongitudeLiu, YangyangGeocode
5Optical beam attenuation coefficient, 401 nmbac4011/mLiu, YangyangSpectrophotometer, WET Labs, Inc., AC-S
6Optical beam attenuation coefficient, 404.6 nmbac404.61/mLiu, YangyangSpectrophotometer, WET Labs, Inc., AC-S
7Optical beam attenuation coefficient, 407.5 nmbac407.51/mLiu, YangyangSpectrophotometer, WET Labs, Inc., AC-S
8Optical beam attenuation coefficient, 410.5 nmbac410.51/mLiu, YangyangSpectrophotometer, WET Labs, Inc., AC-S
9Optical beam attenuation coefficient, 413.9 nmbac413.91/mLiu, YangyangSpectrophotometer, WET Labs, Inc., AC-S
10Optical beam attenuation coefficient, 417.3 nmbac417.31/mLiu, YangyangSpectrophotometer, WET Labs, Inc., AC-S
11Optical beam attenuation coefficient, 421.2 nmbac421.21/mLiu, YangyangSpectrophotometer, WET Labs, Inc., AC-S
12Optical beam attenuation coefficient, 425.3 nmbac425.31/mLiu, YangyangSpectrophotometer, WET Labs, Inc., AC-S
13Optical beam attenuation coefficient, 429 nmbac4291/mLiu, YangyangSpectrophotometer, WET Labs, Inc., AC-S
14Optical beam attenuation coefficient, 432.9 nmbac432.91/mLiu, YangyangSpectrophotometer, WET Labs, Inc., AC-S
15Optical beam attenuation coefficient, 436.4 nmbac436.41/mLiu, YangyangSpectrophotometer, WET Labs, Inc., AC-S
16Optical beam attenuation coefficient, 440.5 nmbac440.51/mLiu, YangyangSpectrophotometer, WET Labs, Inc., AC-S
17Optical beam attenuation coefficient, 444.4 nmbac444.41/mLiu, YangyangSpectrophotometer, WET Labs, Inc., AC-S
18Optical beam attenuation coefficient, 448.8 nmbac448.81/mLiu, YangyangSpectrophotometer, WET Labs, Inc., AC-S
19Optical beam attenuation coefficient, 453 nmbac4531/mLiu, YangyangSpectrophotometer, WET Labs, Inc., AC-S
20Optical beam attenuation coefficient, 457.3 nmbac457.31/mLiu, YangyangSpectrophotometer, WET Labs, Inc., AC-S
21Optical beam attenuation coefficient, 461.3 nmbac461.31/mLiu, YangyangSpectrophotometer, WET Labs, Inc., AC-S
22Optical beam attenuation coefficient, 465.5 nmbac465.51/mLiu, YangyangSpectrophotometer, WET Labs, Inc., AC-S
23Optical beam attenuation coefficient, 469.8 nmbac469.81/mLiu, YangyangSpectrophotometer, WET Labs, Inc., AC-S
24Optical beam attenuation coefficient, 474.3 nmbac474.31/mLiu, YangyangSpectrophotometer, WET Labs, Inc., AC-S
25Optical beam attenuation coefficient, 479.4 nmbac479.41/mLiu, YangyangSpectrophotometer, WET Labs, Inc., AC-S
26Optical beam attenuation coefficient, 483.6 nmbac483.61/mLiu, YangyangSpectrophotometer, WET Labs, Inc., AC-S
27Optical beam attenuation coefficient, 487.9 nmbac487.91/mLiu, YangyangSpectrophotometer, WET Labs, Inc., AC-S
28Optical beam attenuation coefficient, 492 nmbac4921/mLiu, YangyangSpectrophotometer, WET Labs, Inc., AC-S
29Optical beam attenuation coefficient, 496.1 nmbac496.11/mLiu, YangyangSpectrophotometer, WET Labs, Inc., AC-S
30Optical beam attenuation coefficient, 500.5 nmbac500.51/mLiu, YangyangSpectrophotometer, WET Labs, Inc., AC-S
31Optical beam attenuation coefficient, 504.7 nmbac504.71/mLiu, YangyangSpectrophotometer, WET Labs, Inc., AC-S
32Optical beam attenuation coefficient, 509.4 nmbac509.41/mLiu, YangyangSpectrophotometer, WET Labs, Inc., AC-S
33Optical beam attenuation coefficient, 514 nmbac5141/mLiu, YangyangSpectrophotometer, WET Labs, Inc., AC-S
34Optical beam attenuation coefficient, 518.9 nmbac518.91/mLiu, YangyangSpectrophotometer, WET Labs, Inc., AC-S
35Optical beam attenuation coefficient, 523.2 nmbac523.21/mLiu, YangyangSpectrophotometer, WET Labs, Inc., AC-S
36Optical beam attenuation coefficient, 527.5 nmbac527.51/mLiu, YangyangSpectrophotometer, WET Labs, Inc., AC-S
37Optical beam attenuation coefficient, 531.5 nmbac531.51/mLiu, YangyangSpectrophotometer, WET Labs, Inc., AC-S
38Optical beam attenuation coefficient, 535.8 nmbac535.81/mLiu, YangyangSpectrophotometer, WET Labs, Inc., AC-S
39Optical beam attenuation coefficient, 539.7 nmbac539.71/mLiu, YangyangSpectrophotometer, WET Labs, Inc., AC-S
40Optical beam attenuation coefficient, 544 nmbac5441/mLiu, YangyangSpectrophotometer, WET Labs, Inc., AC-S
41Optical beam attenuation coefficient, 548.5 nmbac548.51/mLiu, YangyangSpectrophotometer, WET Labs, Inc., AC-S
42Optical beam attenuation coefficient, 552.4 nmbac552.41/mLiu, YangyangSpectrophotometer, WET Labs, Inc., AC-S
43Optical beam attenuation coefficient, 557.2 nmbac557.21/mLiu, YangyangSpectrophotometer, WET Labs, Inc., AC-S
44Optical beam attenuation coefficient, 561.5 nmbac561.51/mLiu, YangyangSpectrophotometer, WET Labs, Inc., AC-S
45Optical beam attenuation coefficient, 565.6 nmbac565.61/mLiu, YangyangSpectrophotometer, WET Labs, Inc., AC-S
46Optical beam attenuation coefficient, 569.8 nmbac569.81/mLiu, YangyangSpectrophotometer, WET Labs, Inc., AC-S
47Optical beam attenuation coefficient, 573.2 nmbac573.21/mLiu, YangyangSpectrophotometer, WET Labs, Inc., AC-S
48Optical beam attenuation coefficient, 577.1 nmbac577.11/mLiu, YangyangSpectrophotometer, WET Labs, Inc., AC-S
49Optical beam attenuation coefficient, 580.8 nmbac580.81/mLiu, YangyangSpectrophotometer, WET Labs, Inc., AC-S
50Optical beam attenuation coefficient, 582.9 nmbac582.91/mLiu, YangyangSpectrophotometer, WET Labs, Inc., AC-S
51Optical beam attenuation coefficient, 586.4 nmbac586.41/mLiu, YangyangSpectrophotometer, WET Labs, Inc., AC-S
52Optical beam attenuation coefficient, 590.5 nmbac590.51/mLiu, YangyangSpectrophotometer, WET Labs, Inc., AC-S
53Optical beam attenuation coefficient, 594.7 nmbac594.71/mLiu, YangyangSpectrophotometer, WET Labs, Inc., AC-S
54Optical beam attenuation coefficient, 598.9 nmbac598.91/mLiu, YangyangSpectrophotometer, WET Labs, Inc., AC-S
55Optical beam attenuation coefficient, 603.1 nmbac603.11/mLiu, YangyangSpectrophotometer, WET Labs, Inc., AC-S
56Optical beam attenuation coefficient, 607.5 nmbac607.51/mLiu, YangyangSpectrophotometer, WET Labs, Inc., AC-S
57Optical beam attenuation coefficient, 611.8 nmbac611.81/mLiu, YangyangSpectrophotometer, WET Labs, Inc., AC-S
58Optical beam attenuation coefficient, 615.9 nmbac615.91/mLiu, YangyangSpectrophotometer, WET Labs, Inc., AC-S
59Optical beam attenuation coefficient, 620.2 nmbac620.21/mLiu, YangyangSpectrophotometer, WET Labs, Inc., AC-S
60Optical beam attenuation coefficient, 624.2 nmbac624.21/mLiu, YangyangSpectrophotometer, WET Labs, Inc., AC-S
61Optical beam attenuation coefficient, 627.9 nmbac627.91/mLiu, YangyangSpectrophotometer, WET Labs, Inc., AC-S
62Optical beam attenuation coefficient, 632 nmbac6321/mLiu, YangyangSpectrophotometer, WET Labs, Inc., AC-S
63Optical beam attenuation coefficient, 635.8 nmbac635.81/mLiu, YangyangSpectrophotometer, WET Labs, Inc., AC-S
64Optical beam attenuation coefficient, 640 nmbac6401/mLiu, YangyangSpectrophotometer, WET Labs, Inc., AC-S
65Optical beam attenuation coefficient, 644 nmbac6441/mLiu, YangyangSpectrophotometer, WET Labs, Inc., AC-S
66Optical beam attenuation coefficient, 648.1 nmbac648.11/mLiu, YangyangSpectrophotometer, WET Labs, Inc., AC-S
67Optical beam attenuation coefficient, 652.2 nmbac652.21/mLiu, YangyangSpectrophotometer, WET Labs, Inc., AC-S
68Optical beam attenuation coefficient, 656.3 nmbac656.31/mLiu, YangyangSpectrophotometer, WET Labs, Inc., AC-S
69Optical beam attenuation coefficient, 660.6 nmbac660.61/mLiu, YangyangSpectrophotometer, WET Labs, Inc., AC-S
70Optical beam attenuation coefficient, 664.7 nmbac664.71/mLiu, YangyangSpectrophotometer, WET Labs, Inc., AC-S
71Optical beam attenuation coefficient, 668.8 nmbac668.81/mLiu, YangyangSpectrophotometer, WET Labs, Inc., AC-S
72Optical beam attenuation coefficient, 672.9 nmbac672.91/mLiu, YangyangSpectrophotometer, WET Labs, Inc., AC-S
73Optical beam attenuation coefficient, 676.8 nmbac676.81/mLiu, YangyangSpectrophotometer, WET Labs, Inc., AC-S
74Optical beam attenuation coefficient, 680.4 nmbac680.41/mLiu, YangyangSpectrophotometer, WET Labs, Inc., AC-S
75Optical beam attenuation coefficient, 684 nmbac6841/mLiu, YangyangSpectrophotometer, WET Labs, Inc., AC-S
76Optical beam attenuation coefficient, 687.7 nmbac687.71/mLiu, YangyangSpectrophotometer, WET Labs, Inc., AC-S
77Optical beam attenuation coefficient, 691.1 nmbac691.11/mLiu, YangyangSpectrophotometer, WET Labs, Inc., AC-S
78Optical beam attenuation coefficient, 694.7 nmbac694.71/mLiu, YangyangSpectrophotometer, WET Labs, Inc., AC-S
79Optical beam attenuation coefficient, 698.1 nmbac698.11/mLiu, YangyangSpectrophotometer, WET Labs, Inc., AC-S
80Optical beam attenuation coefficient, 701.5 nmbac701.51/mLiu, YangyangSpectrophotometer, WET Labs, Inc., AC-S
81Optical beam attenuation coefficient, standard deviationbac std dev±Liu, YangyangSpectrophotometer, WET Labs, Inc., AC-S401 nm
82Optical beam attenuation coefficient, standard deviationbac std dev±Liu, YangyangSpectrophotometer, WET Labs, Inc., AC-S404.6 nm
83Optical beam attenuation coefficient, standard deviationbac std dev±Liu, YangyangSpectrophotometer, WET Labs, Inc., AC-S407.5 nm
84Optical beam attenuation coefficient, standard deviationbac std dev±Liu, YangyangSpectrophotometer, WET Labs, Inc., AC-S410.5 nm
85Optical beam attenuation coefficient, standard deviationbac std dev±Liu, YangyangSpectrophotometer, WET Labs, Inc., AC-S413.9 nm
86Optical beam attenuation coefficient, standard deviationbac std dev±Liu, YangyangSpectrophotometer, WET Labs, Inc., AC-S417.3 nm
87Optical beam attenuation coefficient, standard deviationbac std dev±Liu, YangyangSpectrophotometer, WET Labs, Inc., AC-S421.2 nm
88Optical beam attenuation coefficient, standard deviationbac std dev±Liu, YangyangSpectrophotometer, WET Labs, Inc., AC-S425.3 nm
89Optical beam attenuation coefficient, standard deviationbac std dev±Liu, YangyangSpectrophotometer, WET Labs, Inc., AC-S429 nm
90Optical beam attenuation coefficient, standard deviationbac std dev±Liu, YangyangSpectrophotometer, WET Labs, Inc., AC-S432.9 nm
91Optical beam attenuation coefficient, standard deviationbac std dev±Liu, YangyangSpectrophotometer, WET Labs, Inc., AC-S436.4 nm
92Optical beam attenuation coefficient, standard deviationbac std dev±Liu, YangyangSpectrophotometer, WET Labs, Inc., AC-S440.5 nm
93Optical beam attenuation coefficient, standard deviationbac std dev±Liu, YangyangSpectrophotometer, WET Labs, Inc., AC-S444.4 nm
94Optical beam attenuation coefficient, standard deviationbac std dev±Liu, YangyangSpectrophotometer, WET Labs, Inc., AC-S448.8 nm
95Optical beam attenuation coefficient, standard deviationbac std dev±Liu, YangyangSpectrophotometer, WET Labs, Inc., AC-S453 nm
96Optical beam attenuation coefficient, standard deviationbac std dev±Liu, YangyangSpectrophotometer, WET Labs, Inc., AC-S457.3 nm
97Optical beam attenuation coefficient, standard deviationbac std dev±Liu, YangyangSpectrophotometer, WET Labs, Inc., AC-S461.3 nm
98Optical beam attenuation coefficient, standard deviationbac std dev±Liu, YangyangSpectrophotometer, WET Labs, Inc., AC-S465.5 nm
99Optical beam attenuation coefficient, standard deviationbac std dev±Liu, YangyangSpectrophotometer, WET Labs, Inc., AC-S469.8 nm
100Optical beam attenuation coefficient, standard deviationbac std dev±Liu, YangyangSpectrophotometer, WET Labs, Inc., AC-S474.3 nm
101Optical beam attenuation coefficient, standard deviationbac std dev±Liu, YangyangSpectrophotometer, WET Labs, Inc., AC-S479.4 nm
102Optical beam attenuation coefficient, standard deviationbac std dev±Liu, YangyangSpectrophotometer, WET Labs, Inc., AC-S483.6 nm
103Optical beam attenuation coefficient, standard deviationbac std dev±Liu, YangyangSpectrophotometer, WET Labs, Inc., AC-S487.9 nm
104Optical beam attenuation coefficient, standard deviationbac std dev±Liu, YangyangSpectrophotometer, WET Labs, Inc., AC-S492 nm
105Optical beam attenuation coefficient, standard deviationbac std dev±Liu, YangyangSpectrophotometer, WET Labs, Inc., AC-S496.1 nm
106Optical beam attenuation coefficient, standard deviationbac std dev±Liu, YangyangSpectrophotometer, WET Labs, Inc., AC-S500.5 nm
107Optical beam attenuation coefficient, standard deviationbac std dev±Liu, YangyangSpectrophotometer, WET Labs, Inc., AC-S504.7 nm
108Optical beam attenuation coefficient, standard deviationbac std dev±Liu, YangyangSpectrophotometer, WET Labs, Inc., AC-S509.4 nm
109Optical beam attenuation coefficient, standard deviationbac std dev±Liu, YangyangSpectrophotometer, WET Labs, Inc., AC-S514 nm
110Optical beam attenuation coefficient, standard deviationbac std dev±Liu, YangyangSpectrophotometer, WET Labs, Inc., AC-S518.9 nm
111Optical beam attenuation coefficient, standard deviationbac std dev±Liu, YangyangSpectrophotometer, WET Labs, Inc., AC-S523.2 nm
112Optical beam attenuation coefficient, standard deviationbac std dev±Liu, YangyangSpectrophotometer, WET Labs, Inc., AC-S527.5 nm
113Optical beam attenuation coefficient, standard deviationbac std dev±Liu, YangyangSpectrophotometer, WET Labs, Inc., AC-S531.5 nm
114Optical beam attenuation coefficient, standard deviationbac std dev±Liu, YangyangSpectrophotometer, WET Labs, Inc., AC-S535.8 nm
115Optical beam attenuation coefficient, standard deviationbac std dev±Liu, YangyangSpectrophotometer, WET Labs, Inc., AC-S539.7 nm
116Optical beam attenuation coefficient, standard deviationbac std dev±Liu, YangyangSpectrophotometer, WET Labs, Inc., AC-S544 nm
117Optical beam attenuation coefficient, standard deviationbac std dev±Liu, YangyangSpectrophotometer, WET Labs, Inc., AC-S548.5 nm
118Optical beam attenuation coefficient, standard deviationbac std dev±Liu, YangyangSpectrophotometer, WET Labs, Inc., AC-S552.4 nm
119Optical beam attenuation coefficient, standard deviationbac std dev±Liu, YangyangSpectrophotometer, WET Labs, Inc., AC-S557.2 nm
120Optical beam attenuation coefficient, standard deviationbac std dev±Liu, YangyangSpectrophotometer, WET Labs, Inc., AC-S561.5 nm
121Optical beam attenuation coefficient, standard deviationbac std dev±Liu, YangyangSpectrophotometer, WET Labs, Inc., AC-S565.6 nm
122Optical beam attenuation coefficient, standard deviationbac std dev±Liu, YangyangSpectrophotometer, WET Labs, Inc., AC-S569.8 nm
123Optical beam attenuation coefficient, standard deviationbac std dev±Liu, YangyangSpectrophotometer, WET Labs, Inc., AC-S573.2 nm
124Optical beam attenuation coefficient, standard deviationbac std dev±Liu, YangyangSpectrophotometer, WET Labs, Inc., AC-S577.1 nm
125Optical beam attenuation coefficient, standard deviationbac std dev±Liu, YangyangSpectrophotometer, WET Labs, Inc., AC-S580.8 nm
126Optical beam attenuation coefficient, standard deviationbac std dev±Liu, YangyangSpectrophotometer, WET Labs, Inc., AC-S582.9 nm
127Optical beam attenuation coefficient, standard deviationbac std dev±Liu, YangyangSpectrophotometer, WET Labs, Inc., AC-S586.4 nm
128Optical beam attenuation coefficient, standard deviationbac std dev±Liu, YangyangSpectrophotometer, WET Labs, Inc., AC-S590.5 nm
129Optical beam attenuation coefficient, standard deviationbac std dev±Liu, YangyangSpectrophotometer, WET Labs, Inc., AC-S594.7 nm
130Optical beam attenuation coefficient, standard deviationbac std dev±Liu, YangyangSpectrophotometer, WET Labs, Inc., AC-S598.9 nm
131Optical beam attenuation coefficient, standard deviationbac std dev±Liu, YangyangSpectrophotometer, WET Labs, Inc., AC-S603.1 nm
132Optical beam attenuation coefficient, standard deviationbac std dev±Liu, YangyangSpectrophotometer, WET Labs, Inc., AC-S607.5 nm
133Optical beam attenuation coefficient, standard deviationbac std dev±Liu, YangyangSpectrophotometer, WET Labs, Inc., AC-S611.8 nm
134Optical beam attenuation coefficient, standard deviationbac std dev±Liu, YangyangSpectrophotometer, WET Labs, Inc., AC-S615.9 nm
135Optical beam attenuation coefficient, standard deviationbac std dev±Liu, YangyangSpectrophotometer, WET Labs, Inc., AC-S620.2 nm
136Optical beam attenuation coefficient, standard deviationbac std dev±Liu, YangyangSpectrophotometer, WET Labs, Inc., AC-S624.2 nm
137Optical beam attenuation coefficient, standard deviationbac std dev±Liu, YangyangSpectrophotometer, WET Labs, Inc., AC-S627.9 nm
138Optical beam attenuation coefficient, standard deviationbac std dev±Liu, YangyangSpectrophotometer, WET Labs, Inc., AC-S632 nm
139Optical beam attenuation coefficient, standard deviationbac std dev±Liu, YangyangSpectrophotometer, WET Labs, Inc., AC-S635.8 nm
140Optical beam attenuation coefficient, standard deviationbac std dev±Liu, YangyangSpectrophotometer, WET Labs, Inc., AC-S640 nm
141Optical beam attenuation coefficient, standard deviationbac std dev±Liu, YangyangSpectrophotometer, WET Labs, Inc., AC-S644 nm
142Optical beam attenuation coefficient, standard deviationbac std dev±Liu, YangyangSpectrophotometer, WET Labs, Inc., AC-S648.1 nm
143Optical beam attenuation coefficient, standard deviationbac std dev±Liu, YangyangSpectrophotometer, WET Labs, Inc., AC-S652.2 nm
144Optical beam attenuation coefficient, standard deviationbac std dev±Liu, YangyangSpectrophotometer, WET Labs, Inc., AC-S656.3 nm
145Optical beam attenuation coefficient, standard deviationbac std dev±Liu, YangyangSpectrophotometer, WET Labs, Inc., AC-S660.6 nm
146Optical beam attenuation coefficient, standard deviationbac std dev±Liu, YangyangSpectrophotometer, WET Labs, Inc., AC-S664.7 nm
147Optical beam attenuation coefficient, standard deviationbac std dev±Liu, YangyangSpectrophotometer, WET Labs, Inc., AC-S668.8 nm
148Optical beam attenuation coefficient, standard deviationbac std dev±Liu, YangyangSpectrophotometer, WET Labs, Inc., AC-S672.9 nm
149Optical beam attenuation coefficient, standard deviationbac std dev±Liu, YangyangSpectrophotometer, WET Labs, Inc., AC-S676.8 nm
150Optical beam attenuation coefficient, standard deviationbac std dev±Liu, YangyangSpectrophotometer, WET Labs, Inc., AC-S680.4 nm
151Optical beam attenuation coefficient, standard deviationbac std dev±Liu, YangyangSpectrophotometer, WET Labs, Inc., AC-S684 nm
152Optical beam attenuation coefficient, standard deviationbac std dev±Liu, YangyangSpectrophotometer, WET Labs, Inc., AC-S687.7 nm
153Optical beam attenuation coefficient, standard deviationbac std dev±Liu, YangyangSpectrophotometer, WET Labs, Inc., AC-S691.1 nm
154Optical beam attenuation coefficient, standard deviationbac std dev±Liu, YangyangSpectrophotometer, WET Labs, Inc., AC-S694.7 nm
155Optical beam attenuation coefficient, standard deviationbac std dev±Liu, YangyangSpectrophotometer, WET Labs, Inc., AC-S698.1 nm
156Optical beam attenuation coefficient, standard deviationbac std dev±Liu, YangyangSpectrophotometer, WET Labs, Inc., AC-S701.5 nm
Size:
2582936 data points

Download Data

Download dataset as tab-delimited text — use the following character encoding:

View dataset as HTML (shows only first 2000 rows)