Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

Herbert, Timothy D; Lawrence, Kira T; Tzanova, Alexandrina; Peterson, Laura C; Caballero-Gill, Rocio P; Kelly, Christopher S (2018): (Table S2) SST estimates as a function of age, ODP Hole 175-1085A [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.885580, In supplement to: Herbert, TD et al. (2016): Late Miocene global cooling and the rise of modern ecosystems. Nature Geoscience, 9(11), 843-847, https://doi.org/10.1038/ngeo2813

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Related to:
Rommerskirchen, Florian; Condon, Tegan; Mollenhauer, Gesine; Dupont, Lydie M; Schefuß, Enno (2011): Miocene to Pliocene development of surface and subsurface temperatures in the Benguela Current system. Paleoceanography, 26, PA3216, https://doi.org/10.1029/2010PA002074
Project(s):
Coverage:
Latitude: -29.374410 * Longitude: 13.990110
Date/Time Start: 1997-09-26T00:15:00 * Date/Time End: 1997-09-29T18:15:00
Minimum DEPTH, sediment/rock: 0.50 m * Maximum DEPTH, sediment/rock: 591.30 m
Event(s):
175-1085A * Latitude: -29.374410 * Longitude: 13.990110 * Date/Time Start: 1997-09-26T00:15:00 * Date/Time End: 1997-09-29T18:15:00 * Elevation: -1713.2 m * Penetration: 604 m * Recovery: 594.39 m * Location: Benguela Current, South Atlantic Ocean * Campaign: Leg175 * Basis: Joides Resolution * Method/Device: Drilling/drill rig (DRILL) * Comment: 64 cores; 604 m cored; 0 m drilled; 98.4 % recovery
Comment:
Data from Rommerskirchen et al. (2011).
Size:
397 data points

Data

Download dataset as tab-delimited text — use the following character encoding:


Sample label
(DSDP/ODP/IODP sample designation)

Depth sed [m]
(mbsf)

Age [ka BP]

Age unc [±]

UK'37

SST (1-12) [°C]
(Calculated from UK'37 (Müller...)

SST (1-12) [°C]
(Modern, extracted from the Wo...)

SST anomaly [°C]
(relative to Modern)

SST anomaly [°C]
(Corrected relative to Modern ...)
175-1085A-1H-1,500.5010.713.450.64018.0617.330.730.73
175-1085A-1H-1,1091.1023.428.650.59016.55-0.78-0.78
175-1085A-1H-2,872.3850.661.350.64018.060.730.73
175-1085A-15H-6,38.135.092946.5224.050.69019.582.252.25
175-1085A-15H-6,112135.832958.4220.050.68019.271.941.94
175-1085A-16H-2,40138.613002.4222.750.64018.060.730.73
175-1085A-17H-3,55149.763228.3199.750.68019.271.941.94
175-1085A-18H-4,55160.763387.9189.050.72020.483.153.15
175-1085A-19H-1,55165.763464.5145.250.71020.182.852.85
175-1085A-20H-2,70176.903635.9111.950.69019.582.252.25
175-1085A-21H-5,70190.903816.0179.750.68019.271.941.94
175-1085A-22H-3,88197.593893.0193.400.76021.704.374.37
175-1085A-23H-2,103205.744016.5182.650.72020.483.153.15
175-1085A-25H-4,58227.284318.983.850.77022.004.674.67
175-1085A-26H-1,70232.444410.979.550.72020.483.153.15
175-1085A-26H-7,45241.164561.386.750.73020.793.463.46
175-1085A-27H-5,58247.794653.884.200.74021.093.763.76
175-1085A-28H-4,57255.774742.0118.850.73020.793.463.46
175-1085A-29H-2,25261.954799.1112.500.71020.182.852.85
175-1085A-29H-6,137269.064881.4105.800.75021.394.064.06
175-1085A-31H-2,76281.385067.8149.900.78022.304.974.97
175-1085A-33H-4,69303.395582.176.600.76021.704.374.37
175-1085A-36X-5,77331.175990.287.050.66018.671.341.34
175-1085A-38X-6,115352.166254.077.450.74021.093.763.76
175-1085A-39X-5,35359.846460.261.300.74021.093.763.76
175-1085A-39X-5,67360.076469.761.700.74021.093.763.76
175-1085A-39X-5,116360.446489.756.500.76021.704.374.37
175-1085A-40X-1,15363.156636.253.200.75021.394.064.06
175-1085A-40X-3,68366.776804.259.100.73020.793.463.46
175-1085A-40X-6,88371.176978.370.750.79022.615.285.28
175-1085A-40X-6,137371.636997.864.700.77022.004.674.67
175-1085A-40X-7,17371.927010.261.950.76021.704.374.37
175-1085A-42X-2,76384.337403.625.800.79022.615.285.28
175-1085A-43X-2,67393.947583.919.900.78022.304.974.97
175-1085A-44X-2,37404.417818.422.950.84024.126.796.79
175-1085A-45X-2,86414.018217.220.550.80022.915.585.58
175-1085A-46X-2,76423.678601.220.850.83023.826.496.49
175-1085A-46X-5,86427.928774.217.900.81023.215.885.88
175-1085A-47X-2,118433.349007.623.500.86024.737.407.40
175-1085A-47X-3,37433.809028.127.200.82023.526.196.19
175-1085A-47X-3,68434.159043.730.850.84024.126.796.79
175-1085A-48X-4,87445.439377.731.450.88025.338.008.00
175-1085A-49X-1,75451.049539.822.400.83023.826.496.49
175-1085A-50X-5,17467.0010050.420.750.88025.338.008.00
175-1085A-50X-5,37467.1410053.120.600.88025.338.008.00
175-1085A-50X-5,67467.3410056.920.500.87025.037.707.70
175-1085A-52X-2,118480.9610411.616.200.87025.037.707.70
175-1085A-53X-2,17489.7510561.423.400.87025.037.707.70
175-1085A-54X-3,67499.8510672.023.600.90025.948.618.61
175-1085A-56X-2,17518.5610986.315.400.92026.559.229.22
175-1085A-56X-2,37518.8110990.716.550.90025.948.618.61
175-1085A-56X-2,77519.3110999.619.550.89025.648.318.31
175-1085A-58X-1,86537.4411360.515.100.91026.248.918.91
175-1085A-59X-4,67550.4711602.519.150.93026.859.529.52
175-1085A-60X-2,116558.4111905.713.150.95027.4510.1210.12
175-1085A-60X-5,76.5562.4312092.611.500.94027.159.829.82
175-1085A-61X-2,116568.0912373.013.650.94027.159.829.82
175-1085A-61X-6,116572.9812598.912.850.93026.859.529.52
175-1085A-62X-2,37.5576.9112770.113.850.92026.559.229.22
175-1085A-62X-4,17579.5312897.919.200.91026.248.918.91
175-1085A-62X-4,37579.7212907.219.750.91026.248.918.91
175-1085A-62X-4,57579.9112916.520.450.90025.948.618.61
175-1085A-62X-5,64581.3913010.814.650.91026.248.918.91
175-1085A-63X-1,57585.2613263.022.050.91026.248.918.91
175-1085A-63X-3,78588.3913486.313.550.94027.159.829.82
175-1085A-63X-5,76.5591.3013670.114.050.94027.009.679.67