Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

Roether, Wolfgang; Huhn, Oliver (2017): Chlorofluorocarbons, Noble Gases and Tritium measurements during POLARSTERN cruise ANT-XXII/3 - Filchner-Ronne Ice Shelf [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.883832

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Related to:
Huhn, Oliver; Hellmer, Hartmut H; Rhein, Monika; Rodehacke, Christian; Roether, Wolfgang; Schodlok, Michael P; Schröder, Michael (2008): Evidence of deep- and bottom-water formation in the western Weddell Sea. Deep Sea Research Part II: Topical Studies in Oceanography, 55(8-9), 1098-1116, https://doi.org/10.1016/j.dsr2.2007.12.015
Funding:
German Research Foundation (DFG), grant/award no. 5472008: Priority Programme 1158 Antarctic Research with Comparable Investigations in Arctic Sea Ice Areas
Coverage:
Median Latitude: -74.968373 * Median Longitude: -45.094957 * South-bound Latitude: -77.141700 * West-bound Longitude: -60.846700 * North-bound Latitude: -73.008300 * East-bound Longitude: -31.003300
Date/Time Start: 1995-01-25T09:07:00 * Date/Time End: 1995-03-01T11:20:00
Minimum DEPTH, water: 6.6 m * Maximum DEPTH, water: 3358.4 m
Event(s):
PS34/112-1 * Latitude: -77.140000 * Longitude: -45.000000 * Date/Time: 1995-01-25T09:07:00 * Elevation: -335.0 m * Campaign: ANT-XII/3 (PS34) * Basis: Polarstern * Method/Device: CTD/Rosette (CTD-RO) * Comment: P_max = 334 dbar; INST.:AWI; CTD-SN:1347; MOOR:yes; operator: Gerd Rohardt
PS34/113-1 * Latitude: -77.141700 * Longitude: -46.331700 * Date/Time: 1995-01-25T12:20:00 * Elevation: -249.0 m * Campaign: ANT-XII/3 (PS34) * Basis: Polarstern * Method/Device: CTD/Rosette (CTD-RO) * Comment: P_max = 248 dbar; INST.:AWI; CTD-SN:1347; MOOR:yes; operator: Gerd Rohardt
PS34/118-1 * Latitude: -76.368300 * Longitude: -47.075000 * Date/Time: 1995-01-26T16:55:00 * Elevation: -285.0 m * Campaign: ANT-XII/3 (PS34) * Basis: Polarstern * Method/Device: CTD/Rosette (CTD-RO) * Comment: P_max = 288 dbar; INST.:AWI; CTD-SN:1347; MOOR:yes; operator: Gerd Rohardt
Comment:
The tracer data set was carefully checked for accurate measurements and outliers. According to the WOCE standards the following flags were applied to each measurement: ? = flag 3 = doubtful; / = flag 4 = bad, # = flag 6 = mean of replicates, * = flag 7 = air corrected.
Methods
Noble gases (3He, 4He, 20Ne)
The water samples for helium isotopes and neon from the CTD-bottle-system are tapped in copper tubes, preventing air contamination and bubbles during the filling of the tubes and squeezed at both ends to keep them gas tight during transportation and storage.
In the IUP Bremen noble gas lab the samples are processed in a first step with a UHV (ultra high vacuum) gas extraction system. The required vacuum conditions are achieved by a rotary pump and an oil diffusion pump. To maintain contamination-free samples, the extraction system is checked for leaks on each sample separately. Sample gases are transferred via water vapor into a glass ampoule kept at liquid nitrogen temperature. Quality checks of this sample preparation line are done on a routine basis. This includes special vacuum checks and preparing accurately defined samples for internal control measurement.
For analysis of the noble gas isotopes the glass ampoules are connected to a fully automated UHV mass spectrometric system equipped with a two stage cryo system. Every 2 to 4 samples the system is calibrated with atmospheric air standards (reproducibility <0.2%). Also measurement of line blanks and linearity are done. The performance of the Bremen facility is described in Sültenfuß et al. (2009, doi:10.1080/10256010902871929).
Error estimate for absolute noble gases concentrations:
D(4He) ± 0.44 %
D(Ne) ± 0.40 %
D(d3He) ± 0.25 %
Chlorofluorocarbons (CFC-11, CFC-12)
The Chlorofluorocarbon (CFC-11 and CFC-12) water samples from the CTD-bottle-system are stored in glass ampoules without contact to the atmosphere during the tapping. Immediately after sampling the ampoules are flame sealed after a CFC free headspace of pure nitrogen had been applied.
The loss of CFCs into the headspace is considered by a careful equilibration between liquid and gas phase under controlled conditions before the sealed ampoules are opened and a precise measurement of the volume of the headspace. The determination of CFC concentrations in the IUP Bremen gas chromatography lab is accomplished by purge and trap sample pre-treatment followed by gas chromatographic (GC) separation on a capillary column and electron capture detection (ECD). The system is calibrated by analyzing several different volumes of a known standard gas. CFC concentrations are calibrated on SIO98 scale (Prinn et al., 2000, doi:10.1029/2000JD900141). A more detailed description of the measurement system is given by Bulsiewicz et at. (1998, doi:10.1029/98JC00140).
Error estimate for CFC-11 and CFC-12 concentrations:
CFC-11 ± 7 %
CFC-12 ± 3 %
Noble gas and CFC data were used e.g. in Huhn et al., 2008 (doi:10.1016/j.dsr2.2007.12.015).
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
1Event labelEventRoether, Wolfgang
2Date/Time of eventDate/TimeRoether, Wolfgang
3Latitude of eventLatitudeRoether, Wolfgang
4Longitude of eventLongitudeRoether, Wolfgang
5Elevation of eventElevationmRoether, Wolfgang
6DEPTH, waterDepth watermRoether, WolfgangGeocode
7Freon-11 (trichorofluoromethane)CFC-11pmol/kgRoether, Wolfgang
8Freon-12 (dichlorodifluoromethane)CFC-12pmol/kgRoether, Wolfgang
9Freon-113CFC-113pmol/kgRoether, Wolfgang
10TetrachloromethaneCCl4pmol/kgRoether, Wolfgang
11HeliumHenmol/kgRoether, Wolfgang
12δ Helium-3δ3He%Roether, Wolfgang100 x ([3He/4He]obs/[3He/4He]atm.- 1)
13NeonNenmol/kgRoether, Wolfgang
14Tritium3HTURoether, Wolfgang
15Bottle numberBottle#Roether, Wolfgang
Size:
1640 data points

Download Data

Download dataset as tab-delimited text — use the following character encoding:

View dataset as HTML