Hoppe, Clara Jule Marie; Schuback, Nina; Semeniuk, David M; Giesbrecht, Karina E; Mol, Jacoba; Thomas, Helmuth; Maldonado, Maria T; Rost, Björn; Varela, Diana E; Tortell, Philippe Daniel (2018): Effect of Ocean Acidification and enhanced irradiances on compositon, productivity and physiology of an Arctic phytoplankton assemblage [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.879778
Always quote citation above when using data! You can download the citation in several formats below.
Keyword(s):
Related to:
Hoppe, Clara Jule Marie; Schuback, Nina; Semeniuk, David M; Giesbrecht, Karina E; Mol, Jacoba; Thomas, H; Maldonado, Maria T; Rost, Björn; Varela, Diana E; Tortell, Philippe Daniel (2018): Resistance of Arctic phytoplankton to ocean acidification and enhanced irradiance. Polar Biology, 41(3), 399-413, https://doi.org/10.1007/s00300-017-2186-0
Original version:
Hoppe, Clara Jule Marie; Schuback, Nina; Semeniuk, David M; Giesbrecht, Karina E; Mol, Jacoba; Thomas, Helmuth; Maldonado, Maria T; Rost, Björn; Varela, Diana E; Tortell, Philippe Daniel (2017): Resistance of an Arctic phytoplankton assemblages to ocean acidification and high irradiance, link to supplement in MS Excel format. PANGAEA, https://doi.org/10.1594/PANGAEA.878255
Further details:
Gattuso, Jean-Pierre; Epitalon, Jean-Marie; Lavigne, Héloïse; Orr, James C; Gentili, Bernard; Proye, Aurélien; Soetaert, Karline; Rae, James (2016): seacarb: seawater carbonate chemistry with R. R package version 3.1. https://cran.r-project.org/package=seacarb
Project(s):
Comment:
In order to allow full comparability with other ocean acidification data sets, the R package seacarb (Gattuso et al, 2016) was used to compute a complete and consistent set of carbonate system variables, as described by Nisumaa et al. (2010). In this dataset the original values were archived in addition with the recalculated parameters (see related PI). The date of carbonate chemistry calculation by seacarb is 2017-08-15.
Parameter(s):
License:
Creative Commons Attribution 3.0 Unported (CC-BY-3.0)
Status:
Curation Level: Enhanced curation (CurationLevelC)
Size:
1192 data points
Data
1 Type (study) | 2 Exp duration [days] | 3 Exp | 4 Assemblage | 5 Treat | 6 Treat | 7 ID (Bottle) | 8 Chl a [µg/l] (total) | 9 Chl a [%] (> 5 mm) | 10 POC [µmol/l] | 11 PON [µmol/l] | 12 bSiO2 [µmol/l] | 13 POC/PON | 14 C/Chl a | 15 POC/bSiO2 | 16 Picopl [#/l] | 17 Picopl/POC [#/ng] | 18 NPP C [µmol/l/day] | 19 PP C/Chl a [µg/µg/day] | 20 NPP C/POC [µmol/µmol/day] | 21 µ [1/day] | 22 Si prod [nmol/l/day] | 23 alpha ETR RCII [(mol electrons/mol RCII)/(µmol quanta/m2)] | 24 CI (95%) | 25 alpha C fix [(mol C/mol Chl a)/(µmol quanta/m2)] | 26 CI (95%) | 27 Pmax ETR RCII [mol electrons/mol RCII/s] | 28 CI (95%) | 29 Pmax C fix [mol electrons/mol Chl a/s] | 30 CI (95%) | 31 Ek [µmol/m2/s] (initial charge separation in ...) | 32 CI (95%) | 33 Ek [µmol/m2/s] (initial charge separation in ...) | 34 CI (95%) | 35 alpha Kc/n PSII | 36 CI (95%) | 37 Pmax Kc/n PSII | 38 CI (95%) | 39 Sal | 40 Temp [°C] | 41 AT [µmol/kg] | 42 DIC [µmol/kg] | 43 pH | 44 pCO2water_SST_wet [µatm] | 45 CSC flag | 46 pH (total scale) | 47 CO2 [µmol/kg] | 48 fCO2water_SST_wet [µatm] | 49 pCO2water_SST_wet [µatm] | 50 [HCO3]- [µmol/kg] | 51 [CO3]2- [µmol/kg] | 52 Omega Arg | 53 Omega Cal |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
laboratory | 8 | initials | Low light | -1.50 | 2253.69 | 2150.00 | 8.045 | 373.60 | 267.29 | 142.452 | 5.7600 | 14.70 | 0.07 | 32.727 | -1.50 | 2253.69 | 2150.00 | 8.045 | 373.60 | 15.00 | 8.05 | 25.09 | 371.05 | 372.72 | 2040.72 | 84.19 | 1.28 | 2.04 | ||||||||||||||||||||||||
laboratory | 8 | initials | High light | -1.50 | 2253.69 | 2150.00 | 8.045 | 373.60 | 267.29 | 142.452 | 5.7600 | 15.98 | 0.07 | 32.727 | -1.50 | 2253.69 | 2150.00 | 8.045 | 373.60 | 15.00 | 8.05 | 25.09 | 371.05 | 372.72 | 2040.72 | 84.19 | 1.28 | 2.04 | ||||||||||||||||||||||||
laboratory | 8 | E2 | dil | Low light | Low pCO2 | A | 11.47 | 75.45 | 41.82 | 7.950 | 4.02 | 5.26 | 79.764 | 10.4029 | 191000000 | 380 | 47.19 | 49.41 | 1.13 | 1.24 | 32.727 | 10.74 | 2290.53 | 2083.00 | 8.107 | 334.90 | 15.00 | 8.12 | 14.37 | 331.25 | 332.52 | 1918.04 | 150.59 | 2.31 | 3.64 | |||||||||||||||||
laboratory | 8 | E2 | dil | Low light | Low pCO2 | B | 14.83 | 85.29 | 46.75 | 8.360 | 6.35 | 5.59 | 74.853 | 7.3565 | 135000000 | 240 | 46.76 | 37.87 | 1.00 | 1.44 | 32.727 | 10.74 | 2289.59 | 2072.00 | 8.128 | 316.00 | 15.00 | 8.14 | 13.56 | 312.55 | 313.74 | 1901.57 | 156.87 | 2.40 | 3.79 | |||||||||||||||||
laboratory | 8 | E2 | dil | Low light | Low pCO2 | C | 10.82 | 78.68 | 42.35 | 10.000 | 4.14 | 4.23 | 76.708 | 10.2360 | 152500000 | 300 | 39.08 | 43.39 | 0.92 | 1.31 | 32.727 | 10.74 | 2292.93 | 2070.00 | 8.139 | 307.70 | 15.00 | 8.15 | 13.20 | 304.15 | 305.31 | 1896.46 | 160.34 | 2.46 | 3.87 | |||||||||||||||||
laboratory | 8 | E2 | dil | Low light | High pCO2 | A | 13.09 | 81.98 | 48.76 | 9.960 | 4.88 | 4.90 | 75.645 | 9.9939 | 131500000 | 225 | 44.90 | 41.21 | 0.92 | 1.19 | 32.727 | 10.74 | 2281.17 | 2242.00 | 7.644 | 1082.20 | 15.00 | 8.09 | 15.45 | 356.20 | 357.56 | 1933.27 | 142.27 | 2.18 | 3.44 | |||||||||||||||||
laboratory | 8 | E2 | dil | Low light | High pCO2 | B | 14.13 | 83.50 | 45.74 | 7.850 | 5.26 | 5.82 | 70.761 | 8.6927 | 139000000 | 253 | 39.98 | 33.98 | 0.87 | 1.25 | 32.727 | 10.74 | 2278.48 | 2224.00 | 7.696 | 953.00 | 15.00 | 8.11 | 14.63 | 337.09 | 338.38 | 1918.35 | 148.03 | 2.27 | 3.58 | |||||||||||||||||
laboratory | 8 | E2 | dil | Low light | High pCO2 | C | 11.43 | 72.90 | 45.13 | 6.960 | 3.85 | 6.49 | 75.308 | 11.7191 | 198500000 | 366 | 1.21 | 32.727 | 10.74 | 2298.79 | 2242.00 | 7.704 | 943.40 | 15.00 | 8.09 | 15.38 | 354.38 | 355.74 | 1937.06 | 143.57 | 2.20 | 3.47 | ||||||||||||||||||||
laboratory | 8 | E2 | dil | High light | Low pCO2 | A | 13.83 | 84.43 | 43.96 | 10.570 | 5.86 | 4.16 | 69.970 | 7.4958 | 142000000 | 269 | 59.55 | 51.72 | 1.35 | 1.34 | 32.727 | 10.74 | 2285.40 | 2091.00 | 8.079 | 359.90 | 15.00 | 7.66 | 46.45 | 1070.47 | 1074.57 | 2137.67 | 57.88 | 0.89 | 1.40 | |||||||||||||||||
laboratory | 8 | E2 | dil | High light | Low pCO2 | B | 16.58 | 88.57 | 51.99 | 8.730 | 6.95 | 5.96 | 66.914 | 7.4785 | 112500000 | 180 | 56.98 | 41.29 | 1.10 | 1.34 | 32.727 | 10.74 | 2284.70 | 2081.00 | 8.100 | 340.00 | 15.00 | 7.71 | 40.94 | 943.61 | 947.23 | 2118.56 | 64.49 | 0.99 | 1.56 | |||||||||||||||||
laboratory | 8 | E2 | dil | High light | Low pCO2 | C | 10.43 | 78.76 | 36.10 | 6.630 | 4.28 | 5.45 | 64.568 | 8.4438 | 155000000 | 357 | 31.66 | 36.47 | 0.88 | 1.27 | 32.727 | 10.74 | 2292.17 | 2096.00 | 8.082 | 358.20 | 15.00 | 7.71 | 40.62 | 936.27 | 939.86 | 2135.34 | 66.03 | 1.01 | 1.59 | |||||||||||||||||
laboratory | 8 | E2 | dil | High light | High pCO2 | A | 9.99 | 74.10 | 34.45 | 6.850 | 2.86 | 5.03 | 65.021 | 12.0656 | 173500000 | 419 | 38.68 | 46.51 | 1.12 | 1.21 | 32.727 | 10.74 | 2284.69 | 2242.00 | 7.655 | 1056.60 | 15.00 | 7.67 | 45.20 | 1041.85 | 1045.84 | 2137.34 | 59.45 | 0.91 | 1.44 | |||||||||||||||||
laboratory | 8 | E2 | dil | High light | High pCO2 | B | 11.52 | 84.16 | 38.11 | 6.070 | 4.51 | 6.28 | 70.848 | 8.4432 | 128500000 | 281 | 47.18 | 49.21 | 1.24 | 1.26 | 32.727 | 10.74 | 2276.74 | 2235.00 | 7.652 | 1061.60 | 15.00 | 7.67 | 45.38 | 1045.86 | 1049.87 | 2130.76 | 58.86 | 0.90 | 1.42 | |||||||||||||||||
laboratory | 8 | E2 | dil | High light | High pCO2 | C | 13.57 | 82.30 | 47.67 | 10.190 | 6.20 | 4.68 | 64.460 | 7.6938 | 180500000 | 315 | 42.88 | 37.96 | 0.90 | 1.35 | 32.727 | 10.74 | 2287.77 | 2241.00 | 7.670 | 1018.40 | 15.00 | 7.68 | 43.79 | 1009.32 | 1013.19 | 2135.92 | 61.29 | 0.94 | 1.48 | |||||||||||||||||
laboratory | 8 | E2 | fin | Low light | Low pCO2 | A | 10.56 | 87.33 | 49.04 | 9.180 | 8.59 | 5.34 | 94.396 | 5.7056 | 137000000 | 233 | 34.82 | 39.62 | 0.71 | 1.14 | 597.56 | 32.687 | 6.27 | 2303.77 | 2105.00 | 8.159 | 291.70 | 15.00 | 8.17 | 14.62 | 289.35 | 290.53 | 1946.69 | 143.69 | 2.19 | 3.47 | ||||||||||||||||
laboratory | 8 | E2 | fin | Low light | Low pCO2 | B | 11.86 | 90.54 | 49.34 | 9.230 | 10.51 | 5.35 | 93.331 | 4.6926 | 69500000 | 117 | 35.72 | 36.16 | 0.72 | 1.05 | 571.99 | 2312.59 | 2100.00 | 8.187 | 272.00 | |||||||||||||||||||||||||||
laboratory | 8 | E2 | fin | Low light | Low pCO2 | C | 10.82 | 92.59 | 50.90 | 11.670 | 9.90 | 4.36 | 94.544 | 5.1417 | 32.687 | 6.27 | 8.168 | |||||||||||||||||||||||||||||||||||
laboratory | 8 | E2 | fin | Low light | High pCO2 | A | 11.62 | 89.63 | 49.48 | 10.960 | 9.40 | 4.52 | 96.996 | 5.2615 | 42000000 | 71 | 47.14 | 48.72 | 0.95 | 1.17 | 651.48 | 32.687 | 6.27 | 2306.14 | 2265.00 | 7.717 | 895.70 | 15.00 | 8.19 | 13.89 | 274.96 | 276.07 | 1939.94 | 150.17 | 2.28 | 3.63 | ||||||||||||||||
laboratory | 8 | E2 | fin | Low light | High pCO2 | B | 12.17 | 88.81 | 48.61 | 8.290 | 10.02 | 5.86 | 94.432 | 4.8513 | 84500000 | 145 | 39.32 | 38.81 | 0.81 | 0.96 | 534.62 | 32.687 | 6.27 | 2307.29 | 2268.00 | 7.710 | 912.30 | 15.00 | 8.16 | 14.81 | 293.16 | 294.35 | 1946.41 | 141.78 | 2.16 | 3.43 | ||||||||||||||||
laboratory | 8 | E2 | fin | Low light | High pCO2 | C | 8.64 | 84.92 | 41.22 | 6.890 | 6.94 | 5.98 | 94.566 | 5.9391 | 85500000 | 173 | 28.00 | 38.94 | 0.68 | 0.96 | 363.95 | 32.687 | 6.27 | 2309.89 | 2276.00 | 7.693 | 952.50 | 15.00 | 8.12 | 16.43 | 325.37 | 326.69 | 1970.62 | 130.95 | 1.99 | 3.16 | ||||||||||||||||
laboratory | 8 | E2 | fin | High light | Low pCO2 | A | 10.56 | 94.68 | 49.22 | 8.380 | 9.88 | 5.88 | 119.627 | 4.9798 | 61500000 | 104 | 33.85 | 38.52 | 0.69 | 0.95 | 429.79 | 32.687 | 6.27 | 2312.76 | 2104.00 | 8.178 | 278.10 | 15.00 | 7.73 | 44.89 | 888.77 | 892.38 | 2162.39 | 57.72 | 0.88 | 1.39 | ||||||||||||||||
laboratory | 8 | E2 | fin | High light | Low pCO2 | B | 12.96 | 93.56 | 57.24 | 8.630 | 13.73 | 6.63 | 120.941 | 4.1688 | 114500000 | 167 | 39.16 | 36.30 | 0.68 | 1.12 | 567.21 | 32.687 | 6.27 | 2298.91 | 2103.00 | 8.152 | 296.50 | 15.00 | 7.72 | 45.61 | 903.01 | 906.67 | 2165.42 | 56.97 | 0.87 | 1.38 | ||||||||||||||||
laboratory | 8 | E2 | fin | High light | Low pCO2 | C | 9.99 | 89.20 | 48.68 | 10.210 | 9.67 | 4.77 | 110.000 | 5.0347 | 154000000 | 263 | 32.97 | 39.64 | 0.68 | 1.10 | 410.87 | 32.687 | 6.27 | 2296.35 | 2118.00 | 8.114 | 327.30 | 15.00 | 7.70 | 47.76 | 945.61 | 949.45 | 2173.43 | 54.81 | 0.83 | 1.32 | ||||||||||||||||
laboratory | 8 | E2 | fin | High light | High pCO2 | A | 8.42 | 83.55 | 42.00 | 7.710 | 5.91 | 5.45 | 102.866 | 7.1100 | 94500000 | 187 | 28.50 | 40.65 | 0.68 | 1.00 | 291.72 | 32.687 | 6.27 | 2309.06 | 2272.00 | 7.704 | 926.20 | 15.00 | 7.71 | 46.50 | 920.66 | 924.40 | 2169.41 | 56.09 | 0.85 | 1.36 | ||||||||||||||||
laboratory | 8 | E2 | fin | High light | High pCO2 | B | 10.03 | 89.90 | 46.78 | 9.150 | 9.32 | 5.11 | 92.396 | 5.0208 | 102500000 | 182 | 34.98 | 41.88 | 0.75 | 1.23 | 578.47 | 32.687 | 6.27 | 2289.61 | 2261.00 | 7.672 | 992.20 | 15.00 | 7.69 | 49.46 | 979.17 | 983.15 | 2159.30 | 52.24 | 0.79 | 1.26 | ||||||||||||||||
laboratory | 8 | E2 | fin | High light | High pCO2 | C | 10.08 | 91.80 | 55.98 | 8.600 | 9.16 | 6.51 | 110.185 | 6.1103 | 90000000 | 134 | 29.02 | 34.59 | 0.52 | 0.97 | 815.34 | 32.687 | 6.27 | 2281.27 | 2254.00 | 7.667 | 1000.70 | 15.00 | 7.68 | 49.83 | 986.56 | 990.57 | 2152.64 | 51.53 | 0.78 | 1.25 | ||||||||||||||||
laboratory | 8 | initial | ||||||||||||||||||||||||||||||||||||||||||||||||||
laboratory | 8 | dilution | Low light | Low pCO2 | 1.73 | 0.58 | 0.0015 | 0.0003 | 206 | 27 | 0.078 | 0.004 | 119 | 43 | 55 | 10 | 1180 | 450 | 2636 | 366 | 32.730 | 10.74 | 2291.01 | 2074.98 | 8.120 | 319.49 | 15.00 | 8.14 | 13.71 | 315.98 | 317.19 | 1905.36 | 155.93 | 2.39 | 3.77 | |||||||||||||||||
laboratory | 8 | dilution | Low light | High pCO2 | 2.21 | 0.29 | 0.0012 | 0.0002 | 167 | 6 | 0.084 | 0.005 | 76 | 10 | 71 | 13 | 1853 | 416 | 1989 | 128 | 32.730 | 10.74 | 2286.15 | 2235.75 | 7.680 | 992.85 | 15.00 | 8.10 | 15.15 | 349.22 | 350.56 | 1929.56 | 144.62 | 2.22 | 3.49 | |||||||||||||||||
laboratory | 8 | dilution | High light | Low pCO2 | 1.55 | 0.64 | 0.0014 | 0.0002 | 154 | 17 | 0.079 | 0.004 | 99 | 42 | 58 | 10 | 1112 | 492 | 1949 | 235 | 32.730 | 10.74 | 2287.42 | 2089.11 | 8.090 | 352.70 | 15.00 | 7.69 | 42.67 | 983.45 | 987.22 | 2130.53 | 62.80 | 0.96 | 1.52 | |||||||||||||||||
laboratory | 8 | dilution | High light | High pCO2 | 2.24 | 0.51 | 0.0011 | 0.0002 | 179 | 10 | 0.080 | 0.003 | 80 | 19 | 71 | 11 | 1987 | 533 | 2246 | 161 | 32.730 | 10.74 | 2283.07 | 2239.49 | 7.660 | 1045.52 | 15.00 | 7.67 | 44.79 | 1032.34 | 1036.30 | 2134.67 | 59.87 | 0.92 | 1.45 | |||||||||||||||||
laboratory | 8 | final | Low light | Low pCO2 | 2.07 | 0.51 | 0.0012 | 0.0004 | 191 | 13 | 0.086 | 0.009 | 92 | 23 | 71 | 23 | 1716 | 676 | 2231 | 270 | 32.690 | 6.27 | 2308.18 | 2102.62 | 8.170 | 281.85 | 15.00 | 8.17 | 14.62 | 289.35 | 290.53 | 1946.69 | 143.69 | 2.19 | 3.47 | |||||||||||||||||
laboratory | 8 | final | Low light | High pCO2 | 2.17 | 0.29 | 0.0011 | 0.0002 | 183 | 7 | 0.084 | 0.005 | 84 | 12 | 73 | 14 | 1906 | 428 | 2190 | 148 | 32.690 | 6.27 | 2307.77 | 2269.47 | 7.710 | 920.12 | 15.00 | 8.16 | 15.04 | 297.83 | 299.04 | 1952.32 | 140.97 | 2.14 | 3.41 | |||||||||||||||||
laboratory | 8 | final | High light | Low pCO2 | 1.73 | 0.26 | 0.0010 | 0.0002 | 220 | 12 | 0.090 | 0.007 | 127 | 20 | 86 | 21 | 1657 | 455 | 2443 | 240 | 32.690 | 6.27 | 2302.67 | 2108.43 | 8.150 | 300.64 | 15.00 | 7.72 | 46.09 | 912.46 | 916.17 | 2167.08 | 56.50 | 0.86 | 1.37 | |||||||||||||||||
laboratory | 8 | final | High light | High pCO2 | 2.24 | 0.43 | 0.0011 | 0.0002 | 209 | 11 | 0.088 | 0.005 | 93 | 19 | 81 | 14 | 2065 | 519 | 2381 | 178 | 32.690 | 6.27 | 2293.31 | 2262.46 | 7.680 | 973.04 | 15.00 | 7.69 | 48.60 | 962.13 | 966.04 | 2160.45 | 53.29 | 0.81 | 1.29 |