# | Name | Short Name | Unit | Principal Investigator | Method/Device | Comment |
1 | Sample code/label | Sample label | | Expedition 357 Scientists | DSDP/ODP/IODP sample designation | |
2 | Core | Core | | Expedition 357 Scientists | | |
3 | Type | Type | | Expedition 357 Scientists | | |
4 | Section | Sect | | Expedition 357 Scientists | | |
5 | DATE/TIME | Date/Time | | Expedition 357 Scientists | | Geocode |
6 | Sample position | Samp pos | | Expedition 357 Scientists | | ICP-OES Autosampler |
7 | Sample ID | Sample ID | | Expedition 357 Scientists | | |
8 | Aluminium | Al | µg/l | Expedition 357 Scientists | ICP-OES, Thermo Scientific, iCAP 6000 | Wavelength (nm): 167.019 |
9 | Barium 2+ | Ba2+ | µg/l | Expedition 357 Scientists | ICP-OES, Thermo Scientific, iCAP 6000 | Wavelength (nm): 455.403 |
10 | Cadmium | Cd | µg/l | Expedition 357 Scientists | ICP-OES, Thermo Scientific, iCAP 6000 | BDL; Wavelength (nm): 228.802 |
11 | Cobalt | Co | µg/l | Expedition 357 Scientists | ICP-OES, Thermo Scientific, iCAP 6000 | BDL; Wavelength (nm): 228.615 |
12 | Chromium | Cr | µg/l | Expedition 357 Scientists | ICP-OES, Thermo Scientific, iCAP 6000 | BDL; Wavelength (nm): 267.716 |
13 | Copper | Cu | µg/l | Expedition 357 Scientists | ICP-OES, Thermo Scientific, iCAP 6000 | BDL; Wavelength (nm): 327.395 |
14 | Iron | Fe | µg/l | Expedition 357 Scientists | ICP-OES, Thermo Scientific, iCAP 6000 | Wavelength (nm): 238.204 |
15 | Lithium | Li | µg/l | Expedition 357 Scientists | ICP-OES, Thermo Scientific, iCAP 6000 | Wavelength (nm): 670.783 |
16 | Manganese | Mn | nmol/l | Expedition 357 Scientists | ICP-OES, Thermo Scientific, iCAP 6000 | Wavelength (nm): 259.372; original unit [µg/l] |
17 | Molybdenum | Mo | µg/l | Expedition 357 Scientists | ICP-OES, Thermo Scientific, iCAP 6000 | BDL; Wavelength (nm): 202.032 |
18 | Nickel | Ni | µg/l | Expedition 357 Scientists | ICP-OES, Thermo Scientific, iCAP 6000 | BDL; Wavelength (nm): 227.021 |
19 | Phosphorus | P | µg/l | Expedition 357 Scientists | ICP-OES, Thermo Scientific, iCAP 6000 | No good peak; Wavelength (nm): 177.434 |
20 | Lead | Pb | µg/l | Expedition 357 Scientists | ICP-OES, Thermo Scientific, iCAP 6000 | BDL; Wavelength (nm): 220.353 |
21 | Strontium | Sr | µmol/l | Expedition 357 Scientists | ICP-OES, Thermo Scientific, iCAP 6000 | Values too high (hence the) for this ICP, use the Varian radial analyses; Wavelength (nm): 407.771; original unit [µg/l] |
22 | Titanium | Ti | µg/l | Expedition 357 Scientists | ICP-OES, Thermo Scientific, iCAP 6000 | BDL; Wavelength (nm): 334.941 |
23 | Vanadium | V | µg/l | Expedition 357 Scientists | ICP-OES, Thermo Scientific, iCAP 6000 | BDL; Wavelength (nm): 292.401 |
24 | Zinc | Zn | µg/l | Expedition 357 Scientists | ICP-OES, Thermo Scientific, iCAP 6000 | Mn interference contamination; Wavelength (nm): 213.857 |