Coverage:
Latitude: 30.132400 * Longitude: -42.120030
Date/Time Start: 2015-11-06T00:00:00 * Date/Time End: 2015-11-08T00:00:00
Minimum Elevation: -850.9 m * Maximum Elevation: -850.9 m
Event(s):
357-M0069A (AM-06A) * Latitude: 30.132400 * Longitude: -42.120030 * Date/Time Start: 2015-11-06T00:00:00 * Date/Time End: 2015-11-08T00:00:00 * Elevation: -850.9 m * IGSN: IBCR0357EHA0001 * Location: Atlantis Massif * Campaign: Exp357 * Basis: James Cook * Comment: RD2, CTD: 30 7.985N / 42 7.218W; back on deck 10:30; MeBo launched 12:26, failed, back on deck 15:00; launch RD2 at midnight
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
1Sample code/labelSample labelExpedition 357 ScientistsDSDP/ODP/IODP sample designation
2CoreCoreExpedition 357 Scientists
3TypeTypeExpedition 357 Scientists
4SectionSectExpedition 357 Scientists
5DATE/TIMEDate/TimeExpedition 357 ScientistsGeocode
6Sample positionSamp posExpedition 357 ScientistsICP-OES Autosampler
7Sample IDSample IDExpedition 357 Scientists
8AluminiumAlµg/lExpedition 357 ScientistsICP-OES, Thermo Scientific, iCAP 6000Wavelength (nm): 167.019
9Barium 2+Ba2+µg/lExpedition 357 ScientistsICP-OES, Thermo Scientific, iCAP 6000Wavelength (nm): 455.403
10CadmiumCdµg/lExpedition 357 ScientistsICP-OES, Thermo Scientific, iCAP 6000BDL; Wavelength (nm): 228.802
11CobaltCoµg/lExpedition 357 ScientistsICP-OES, Thermo Scientific, iCAP 6000BDL; Wavelength (nm): 228.615
12ChromiumCrµg/lExpedition 357 ScientistsICP-OES, Thermo Scientific, iCAP 6000BDL; Wavelength (nm): 267.716
13CopperCuµg/lExpedition 357 ScientistsICP-OES, Thermo Scientific, iCAP 6000BDL; Wavelength (nm): 327.395
14IronFeµg/lExpedition 357 ScientistsICP-OES, Thermo Scientific, iCAP 6000Wavelength (nm): 238.204
15LithiumLiµg/lExpedition 357 ScientistsICP-OES, Thermo Scientific, iCAP 6000Wavelength (nm): 670.783
16ManganeseMnnmol/lExpedition 357 ScientistsICP-OES, Thermo Scientific, iCAP 6000Wavelength (nm): 259.372; original unit [µg/l]
17MolybdenumMoµg/lExpedition 357 ScientistsICP-OES, Thermo Scientific, iCAP 6000BDL; Wavelength (nm): 202.032
18NickelNiµg/lExpedition 357 ScientistsICP-OES, Thermo Scientific, iCAP 6000BDL; Wavelength (nm): 227.021
19PhosphorusPµg/lExpedition 357 ScientistsICP-OES, Thermo Scientific, iCAP 6000No good peak; Wavelength (nm): 177.434
20LeadPbµg/lExpedition 357 ScientistsICP-OES, Thermo Scientific, iCAP 6000BDL; Wavelength (nm): 220.353
21StrontiumSrµmol/lExpedition 357 ScientistsICP-OES, Thermo Scientific, iCAP 6000Values too high (hence the) for this ICP, use the Varian radial analyses; Wavelength (nm): 407.771; original unit [µg/l]
22TitaniumTiµg/lExpedition 357 ScientistsICP-OES, Thermo Scientific, iCAP 6000BDL; Wavelength (nm): 334.941
23VanadiumVµg/lExpedition 357 ScientistsICP-OES, Thermo Scientific, iCAP 6000BDL; Wavelength (nm): 292.401
24ZincZnµg/lExpedition 357 ScientistsICP-OES, Thermo Scientific, iCAP 6000Mn interference contamination; Wavelength (nm): 213.857
25ZirconiumZrµg/lExpedition 357 ScientistsICP-OES, Thermo Scientific, iCAP 6000BDL; Wavelength (nm): 343.823
Size:
157 data points