Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

Neumann, Thomas (1993): (Appendix A3) Element concentration in leaching residuals of Mariana back-arc sediment cores [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.869145, In supplement to: Neumann, T (1993): Porenwasserchemismus in jungen vulkanogenen Sedimenten des Marianen Back-arc Gebietes: Charakterisierung und Genese. Berichte-Reports, Geologisch-Paläontologisches Institut der Universität Kiel, 62, 99 pp, https://doi.org/10.2312/reports-gpi.1993.62

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Coverage:
Median Latitude: 18.092346 * Median Longitude: 144.744648 * South-bound Latitude: 18.008833 * West-bound Longitude: 144.580000 * North-bound Latitude: 18.227833 * East-bound Longitude: 144.891500
Date/Time Start: 1990-07-22T00:00:00 * Date/Time End: 1990-07-30T00:00:00
Minimum DEPTH, sediment/rock: m * Maximum DEPTH, sediment/rock: m
Event(s):
GIK17576-1 (SO69-035)  * Latitude: 18.017500 * Longitude: 144.891500 * Date/Time: 1990-07-22T00:00:00 * Elevation: -4406.0 m * Location: Mariana back-arc area * Campaign: SO69 (MARIANA II) * Basis: Sonne * Method/Device: Giant box corer (GKG)
GIK17580-1 (SO69-039)  * Latitude: 18.008833 * Longitude: 144.832500 * Date/Time: 1990-07-24T00:00:00 * Elevation: -3970.0 m * Location: Mariana back-arc area * Campaign: SO69 (MARIANA II) * Basis: Sonne * Method/Device: Giant box corer (GKG)
GIK17582-1 (SO69-041)  * Latitude: 18.052667 * Longitude: 144.784500 * Date/Time: 1990-07-25T00:00:00 * Elevation: -4370.0 m * Location: Mariana back-arc area * Campaign: SO69 (MARIANA II) * Basis: Sonne * Method/Device: Giant box corer (GKG)
Size:
585 data points

Data

Download dataset as tab-delimited text — use the following character encoding:


Event

Event 2

Latitude

Longitude

Elevation [m]

Sample comment

Depth sed [m]

Fe [%]

Mg [%]
10 
Ca [%]
11 
Al [%]
12 
Ti [mg/kg]
13 
Mn [mg/kg]
14 
Cr [mg/kg]
15 
Co [mg/kg]
16 
Ni [mg/kg]
17 
Cu [mg/kg]
18 
Zn [mg/kg]
19 
As [mg/kg]
GIK17576-1 SO69-03518.0175144.8915-4406residual03.31.03.04.614309005.19.22.520650.96
GIK17576-1SO69-03518.0175144.8915-4406HCl02.70.62.13.010303206.67.93.645102.14
GIK17576-1SO69-03518.0175144.8915-4406reduced00.40.30.00.245600.52.01.110101.97
GIK17576-1SO69-03518.0175144.8915-4406HAc01.00.10.40.659902.53.52.150403.25
GIK17576-1SO69-03518.0175144.8915-4406total07.42.05.58.42510227014.722.69.31251258.32
GIK17580-1 SO69-03918.0088144.8325-3970residual03.41.13.14.915209304.210.90.620601.17
GIK17580-1SO69-03918.0088144.8325-3970HCl02.60.62.13.110503206.66.54.130151.57
GIK17580-1SO69-03918.0088144.8325-3970reduced00.60.20.10.225600.32.00.93052.09
GIK17580-1SO69-03918.0088144.8325-3970HAc00.80.10.40.659402.23.52.585902.71
GIK17580-1SO69-03918.0088144.8325-3970total07.42.05.78.82600225013.322.98.11651707.54
GIK17582-1 SO69-04118.0527144.7845-4370residual03.51.02.94.616108805.610.42.030600.87
GIK17582-1SO69-04118.0527144.7845-4370HCl03.00.82.43.310803408.36.84.745202.37
GIK17582-1SO69-04118.0527144.7845-4370reduced00.40.10.00.120300.32.81.11051.94
GIK17582-1SO69-04118.0527144.7845-4370HAc01.00.20.40.73010902.53.82.7100952.68
GIK17582-1SO69-04118.0527144.7845-4370total07.92.15.78.72740234016.723.810.51851807.86
GIK17587-1 SO69-04618.0490144.7335-4260residual03.31.02.94.415208806.110.60.930651.18
GIK17587-1SO69-04618.0490144.7335-4260HCl02.70.72.13.110403007.66.73.535151.94
GIK17587-1SO69-04618.0490144.7335-4260reduced00.60.20.10.250400.92.42.02552.75
GIK17587-1SO69-04618.0490144.7335-4260HAc01.00.20.40.63013103.74.24.150453.86
GIK17587-1SO69-04618.0490144.7335-4260total07.62.15.58.32640253018.323.910.51401309.73
GIK17590-1 SO69-04918.0188144.5800-3320residual02.81.02.54.115108104.611.01.510601.10
GIK17590-1SO69-04918.0188144.5800-3320HCl02.90.72.23.111102606.93.82.855152.16
GIK17590-1SO69-04918.0188144.5800-3320reduced00.50.20.00.3153101.14.52.42553.47
GIK17590-1SO69-04918.0188144.5800-3320HAc01.10.11.20.6513302.34.13.460602.94
GIK17590-1SO69-04918.0188144.5800-3320total07.32.05.98.12640271014.923.410.11501409.67
GIK17594-1 SO69-05318.0334144.6795-3520residual03.41.12.94.616908805.412.42.425651.01
GIK17594-1SO69-05318.0334144.6795-3520HCl02.70.61.93.110602906.74.23.445152.55
GIK17594-1SO69-05318.0334144.6795-3520reduced00.50.30.10.2301200.83.20.020102.17
GIK17594-1SO69-05318.0334144.6795-3520HAc00.90.10.80.31012103.04.34.945403.16
GIK17594-1SO69-05318.0334144.6795-3520total07.52.15.78.52790250015.924.110.71351308.89
GIK17603-1 SO69-06218.2027144.7397-3820residual03.71.13.35.4176010903.913.82.415701.46
GIK17603-1SO69-06218.2027144.7397-3820HCl02.30.51.62.67902104.32.21.635151.63
GIK17603-1SO69-06218.2027144.7397-3820reduced00.50.20.30.158601.04.10.42551.88
GIK17603-1SO69-06218.2027144.7397-3820HAc00.80.10.30.629102.23.13.260602.56
GIK17603-1SO69-06218.2027144.7397-3820total07.31.95.58.72610227011.423.27.61351507.53
GIK17597-1 SO69-05618.2203144.6915-3820residual03.31.12.94.715709305.414.11.480651.39
GIK17597-1SO69-05618.2203144.6915-3820HCl02.70.61.82.910402505.70.53.930152.10
GIK17597-1SO69-05618.2203144.6915-3820reduced00.50.20.10.1381100.93.91.93052.45
GIK17597-1SO69-05618.2203144.6915-3820HAc00.90.10.50.6212902.45.32.250753.67
GIK17597-1SO69-05618.2203144.6915-3820total07.42.05.38.32650258014.423.89.41901609.61
GIK17605-1 SO69-06418.2278144.7692-3710residual03.61.13.45.4167010504.214.42.340701.28
GIK17605-1SO69-06418.2278144.7692-3710HCl02.60.51.82.610102404.71.91.830151.47
GIK17605-1SO69-06418.2278144.7692-3710reduced00.60.30.10.320700.73.40.51551.40
GIK17605-1SO69-06418.2278144.7692-3710HAc00.70.10.40.5208901.74.73.055652.33
GIK17605-1SO69-06418.2278144.7692-3710total07.52.05.78.82720225011.324.47.61401556.48