Titschack, Jürgen; Fink, Hiske G; Baum, Daniel; Wienberg, Claudia; Hebbeln, Dierk; Freiwald, André (2016): Clast angle distribution of sediment core GeoB11135-2 [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.867253, In supplement to: Titschack, J et al. (2016): Mediterranean cold-water corals - an important regional carbonate factory? The Depositional Record, 2(1), 74-96, https://doi.org/10.1002/dep2.14
Always quote citation above when using data! You can download the citation in several formats below.
Project(s):
Coverage:
Latitude: 36.839180 * Longitude: 13.155800
Date/Time Start: 2006-10-01T21:44:00 * Date/Time End: 2006-10-01T21:44:00
Minimum DEPTH, sediment/rock: 0.0000 m * Maximum DEPTH, sediment/rock: 5.7800 m
Event(s):
M70/1_680-2 (GeoB11135-2) * Latitude: 36.839180 * Longitude: 13.155800 * Date/Time: 2006-10-01T21:44:00 * Elevation: -636.0 m * Recovery: 5.78 m * Location: Urania Bank * Campaign: M70/1 * Basis: Meteor (1986) * Method/Device: Gravity corer (Kiel type) (SL)
Comment:
bin boundaries are in degree.Unit: volume-%.
Parameter(s):
# | Name | Short Name | Unit | Principal Investigator | Method/Device | Comment |
---|---|---|---|---|---|---|
1 | DEPTH, sediment/rock | Depth sed | m | Titschack, Jürgen | Geocode | |
2 | Number of slice | No slice | # | Titschack, Jürgen | Computer tomography (CT) Toshiba Aquilion 64 | |
3 | Number of voxels | No voxels | # | Titschack, Jürgen | Computer tomography (CT) Toshiba Aquilion 64 | |
4 | Number of labels | No labels | # | Titschack, Jürgen | Computer tomography (CT) Toshiba Aquilion 64 | |
5 | Clast angle distribution | Clast angle distr | % | Titschack, Jürgen | Computer tomography (CT) Toshiba Aquilion 64 | bin 0: [0.00,5.00) |
6 | Clast angle distribution | Clast angle distr | % | Titschack, Jürgen | Computer tomography (CT) Toshiba Aquilion 64 | bin 1: [5.00,10.00) |
7 | Clast angle distribution | Clast angle distr | % | Titschack, Jürgen | Computer tomography (CT) Toshiba Aquilion 64 | bin 2: [10.00,15.00) |
8 | Clast angle distribution | Clast angle distr | % | Titschack, Jürgen | Computer tomography (CT) Toshiba Aquilion 64 | bin 3: [15.00,20.00) |
9 | Clast angle distribution | Clast angle distr | % | Titschack, Jürgen | Computer tomography (CT) Toshiba Aquilion 64 | bin 4: [20.00,25.00) |
10 | Clast angle distribution | Clast angle distr | % | Titschack, Jürgen | Computer tomography (CT) Toshiba Aquilion 64 | bin 5: [25.00,30.00) |
11 | Clast angle distribution | Clast angle distr | % | Titschack, Jürgen | Computer tomography (CT) Toshiba Aquilion 64 | bin 6: [30.00,35.00) |
12 | Clast angle distribution | Clast angle distr | % | Titschack, Jürgen | Computer tomography (CT) Toshiba Aquilion 64 | bin 7: [35.00,40.00) |
13 | Clast angle distribution | Clast angle distr | % | Titschack, Jürgen | Computer tomography (CT) Toshiba Aquilion 64 | bin 8: [40.00,45.00) |
14 | Clast angle distribution | Clast angle distr | % | Titschack, Jürgen | Computer tomography (CT) Toshiba Aquilion 64 | bin 9: [45.00,50.00) |
15 | Clast angle distribution | Clast angle distr | % | Titschack, Jürgen | Computer tomography (CT) Toshiba Aquilion 64 | bin 10: [50.00,55.00) |
16 | Clast angle distribution | Clast angle distr | % | Titschack, Jürgen | Computer tomography (CT) Toshiba Aquilion 64 | bin 11: [55.00,60.00) |
17 | Clast angle distribution | Clast angle distr | % | Titschack, Jürgen | Computer tomography (CT) Toshiba Aquilion 64 | bin 12: [60.00,65.00) |
18 | Clast angle distribution | Clast angle distr | % | Titschack, Jürgen | Computer tomography (CT) Toshiba Aquilion 64 | bin 13: [65.00,70.00) |
19 | Clast angle distribution | Clast angle distr | % | Titschack, Jürgen | Computer tomography (CT) Toshiba Aquilion 64 | bin 14: [70.00,75.00) |
20 | Clast angle distribution | Clast angle distr | % | Titschack, Jürgen | Computer tomography (CT) Toshiba Aquilion 64 | bin 15: [75.00,80.00) |
21 | Clast angle distribution | Clast angle distr | % | Titschack, Jürgen | Computer tomography (CT) Toshiba Aquilion 64 | bin 16: [80.00,85.00) |
22 | Clast angle distribution | Clast angle distr | % | Titschack, Jürgen | Computer tomography (CT) Toshiba Aquilion 64 | bin 17: [85.00,90.00] |
License:
Creative Commons Attribution 3.0 Unported (CC-BY-3.0)
Size:
391776 data points
Download Data