Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

Weller, Rolf (2016): Airchemistry at Neumayer station, Antarctica during the year 2015 [dataset]. Alfred Wegener Institute, Helmholtz Centre for Polar and Marine Research, Bremerhaven, PANGAEA, https://doi.org/10.1594/PANGAEA.860939, In: Weller, Rolf (2023): Airchemistry at Neumayer station, Antarctica [dataset publication series]. Alfred Wegener Institute, Helmholtz Centre for Polar and Marine Research, Bremerhaven, PANGAEA, https://doi.org/10.1594/PANGAEA.961235

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Project(s):
Coverage:
Latitude: -70.650000 * Longitude: -8.250000
Date/Time Start: 2015-01-01T00:00:00 * Date/Time End: 2015-12-31T23:59:00
Minimum ALTITUDE: 42 m * Maximum ALTITUDE: 42 m
Event(s):
Neumayer_SPUSO * Latitude: -70.650000 * Longitude: -8.250000 * Date/Time: 1983-01-01T00:00:00 * Elevation: 42.0 m * Location: Dronning Maud Land, Antarctica * Campaign: Neumayer_based * Basis: NEUMAYER III * Method/Device: Air chemistry observatory (SPUSO)
Comment:
Data processing by Johannes Kässbohrer, Fielax
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
1DATE/TIMEDate/TimeWeller, RolfGeocode
2ALTITUDEAltitudemWeller, RolfGeocode
3Temperature, airTTT°CWeller, Rolf
4Wind speedffm/sWeller, Rolf
5Wind directiondddegWeller, Rolf
6Total extinction coefficient at 450 nmscblue1/mWeller, RolfNephelometer TSI 3563 (neph3563_1017)Detection limit approx. 10^-7 1/m. Averaging time is generally 600 sec.
7Total extinction coefficient at 550 nmscgreen1/mWeller, RolfNephelometer TSI 3563 (neph3563_1017)Detection limit approx. 10^-7 1/m. Averaging time is generally 600 sec.
8Total extinction coefficient at 700 nmscred1/mWeller, RolfNephelometer TSI 3563 (neph3563_1017)Detection limit approx. 10^-7 1/m. Averaging time is generally 600 sec.
9Extinction coefficient at 450 nm, backscattering modebscblue1/mWeller, RolfNephelometer TSI 3563 (neph3563_1017)Detection limit approx. 10^-7 1/m. Averaging time is generally 600 sec.
10Extinction coefficient at 550 nm, backscattering modebscgreen1/mWeller, RolfNephelometer TSI 3563 (neph3563_1017)Detection limit approx. 10^-7 1/m. Averaging time is generally 600 sec.
11Extinction coefficient at 700 nm, backscattering modebscred1/mWeller, RolfNephelometer TSI 3563 (neph3563_1017)Detection limit approx. 10^-7 1/m. Averaging time is generally 600 sec.
12Particle numberCP_conc#/cm3Weller, RolfCondensation particle counter (CPC), TSI, 3022A (cpc3775)Uncertainties are approx. +/-5%; screened for wind velocities > 2 m/s and wind direction
13OzoneO3ppbvWeller, RolfSurface ozone analyzer ansyco O341M (O341M_1167)Uncertainties are approx. +/-2 ppbv
14Date/time endDate/time endWeller, RolfSampling period high volume aerosol sampling
15Methane sulfonic acidMSAng/m3Weller, RolfHigh volume aerosol sampling (HV-LV-sampling-SPUSO)Uncertainties are approximately ±10% to ±15%
16ChlorideClng/m3Weller, RolfHigh volume aerosol sampling (HV-LV-sampling-SPUSO)Uncertainties are approximately ±10% to ±15%
17BromideBrng/m3Weller, RolfHigh volume aerosol sampling (HV-LV-sampling-SPUSO)Uncertainties are approximately ±20% to ±30%
18NitrateNO3ng/m3Weller, RolfHigh volume aerosol sampling (HV-LV-sampling-SPUSO)Uncertainties are approximately ±10% to ±15%
19Sulfate[SO4]2-ng/m3Weller, RolfHigh volume aerosol sampling (HV-LV-sampling-SPUSO)Uncertainties are approximately ±10% to ±15%
20SodiumNang/m3Weller, RolfHigh volume aerosol sampling (HV-LV-sampling-SPUSO)Uncertainties are approximately ±10% to ±15%
21Ammonium[NH4]+ng/m3Weller, RolfHigh volume aerosol sampling (HV-LV-sampling-SPUSO)Uncertainties are approximately ±20% to ±30%
22PotassiumKng/m3Weller, RolfHigh volume aerosol sampling (HV-LV-sampling-SPUSO)Uncertainties are approximately ±20% to ±30%
23MagnesiumMgng/m3Weller, RolfHigh volume aerosol sampling (HV-LV-sampling-SPUSO)Uncertainties are approximately ±20% to ±30%
24CalciumCang/m3Weller, RolfHigh volume aerosol sampling (HV-LV-sampling-SPUSO)Uncertainties are approximately ±20% to ±30%
Size:
3969382 data points

Download Data

Download dataset as tab-delimited text — use the following character encoding:

View dataset as HTML (shows only first 2000 rows)