Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

Li, Lei; Zhao, Ning; Wei, Wei; Sun, Yuhan (2016): Table 2. Performance summary of K-based sorbents capturing CO2 [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.859395, Supplement to: Li, L et al. (2013): A review of research progress on CO2 capture, storage, and utilization in Chinese Academy of Sciences. Fuel, 108, 112-130, https://doi.org/10.1016/j.fuel.2011.08.022

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX Citation

Abstract:
This article reviews the progress made in CO2 capture, storage, and utilization in Chinese Academy of Sciences (CAS). New concepts such as adsorption using dry regenerable solid sorbents as well as functional ionic liquids (ILs) for CO2 capture are thoroughly discussed. Carbon sequestration, such as geological sequestration, mineral carbonation and ocean storage are also covered. The utilization of CO2 as a raw material in the synthesis of chemicals and liquid energy carriers which offers a way to mitigate the increasing CO2 buildup is introduced.
Funding:
Seventh Framework Programme (FP7), grant/award no. 265847: Sub-seabed CO2 Storage: Impact on Marine Ecosystems
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
MaterialMaterialLi, Leia Activated carbon.
b Modified K2CO3/Al2O3 sorbent.
c K-Fe sorbent (K2CO3, 33.33 wt.%; FeOOH, 66.67 wt.%).
d Commercial sorbent (K2CO3, 35 wt.%; supporters, 65 wt.%).
Temperature, technicalT tech°CLi, Lei
Carbon dioxide, partial pressurepCO2PaLi, Lei
CapacityCapacmmol/gLi, LeiCO2/sorbent
Analytical methodMethodLi, Lei
Temperature, technicalT tech°CLi, Leiof regenerature
Temperature, technicalT tech°CLi, Leiof regenerature max
Reference/sourceReferenceLi, Lei
Size:
123 data points

Data

Download dataset as tab-delimited text — use the following character encoding:


Material
(a Activated carbon. b Modifie...)

T tech [°C]

pCO2 [Pa]

Capac [mmol/g]
(CO2/sorbent)

Method

T tech [°C]
(of regenerature)

T tech [°C]
(of regenerature max)

Reference
K2CO3/AC a601.001.95thermal conductivity detector15062
K2CO3/SiO2601.000.23thermal conductivity detector62
K2CO3/USY601.000.43thermal conductivity detector62
K2CO3/CsNaX601.001.35thermal conductivity detector62
K2CO3/Al2O3601.001.93thermal conductivity detector35062
K2CO3/CaO601.001.11thermal conductivity detector62
K2CO3/MgO601.002.70thermal conductivity detector40062
K2CO3/TiO2601.001.89thermal conductivity detector15062
K2CO3/Al2O3601.001.96thermal conductivity detector>30063
Re-KAl(I)30 b601.001.86thermal conductivity detector<20063
K2CO3/TiO2601.002.05thermal conductivity detector20064
K2CO3/MgO601.002.98thermal conductivity detector35040065
K2CO3/ZrO2501.002.08thermal conductivity detector13020066
K2CO3601.000.05gas analyzer, fixed bed67
K-Fe sorbent c601.001.12gas analyzer, fixed bed15067
K2CO3/Al2O36013.00thermogravimetric analysis35068
sorbKX35 d6010.002.53gas analyzer, fluidized bed30069,70
sorbKX35 d7014.402.05thermogravimetric analysis15023071