Jonkers, Lukas; Barker, Stephen; Hall, Ian R; Prins, Maarten Arnoud (2015): Raw grain size analysis as measured by laser diffraction at Hole 162-983A [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.854782, In supplement to: Jonkers, L et al. (2015): Correcting for the influence of ice-rafted detritus on grain size-based paleocurrent speed estimates. Paleoceanography, 30(10), 1347-1357, https://doi.org/10.1002/2015PA002830
Always quote citation above when using data! You can download the citation in several formats below.
Published: 2015-11-05 • DOI registered: 2015-12-04
Project(s):
Ocean Drilling Program (ODP)
Coverage:
Latitude: 60.403300 * Longitude: -23.640600
Date/Time Start: 1995-07-21T11:58:00 * Date/Time End: 1995-07-22T09:29:00
Minimum DEPTH, sediment/rock: 3.00 m * Maximum DEPTH, sediment/rock: 5.00 m
Event(s):
162-983A * Latitude: 60.403300 * Longitude: -23.640600 * Date/Time Start: 1995-07-21T11:58:00 * Date/Time End: 1995-07-22T09:29:00 * Elevation: -1983.0 m * Penetration: 254.4 m * Recovery: 264.42 m * Location: North Atlantic Ocean * Campaign: Leg162 * Basis: Joides Resolution * Method/Device: Drilling/drill rig (DRILL) * Comment: 27 cores; 254.4 m cored; 0 m drilled; 103.9 % recovery
Comment:
µm-values in the parameter comment indicate the upper limit of the size fraction measured.
Parameter(s):
| # | Name | Short Name | Unit | Principal Investigator | Method/Device | Comment |
|---|---|---|---|---|---|---|
| 1 | Sample code/label | Sample label | Jonkers, Lukas | DSDP/ODP/IODP sample designation | ODP sample designation | |
| 2 | DEPTH, sediment/rock | Depth sed | m | Jonkers, Lukas | Geocode – given in mcd | |
| 3 | Size fraction | Size fraction | % | Jonkers, Lukas | Laser Particle Analyser, Fritsch GmbH, Analysette 22 | 0.12 µm |
| 4 | Size fraction | Size fraction | % | Jonkers, Lukas | Laser Particle Analyser, Fritsch GmbH, Analysette 22 | 0.15 µm |
| 5 | Size fraction | Size fraction | % | Jonkers, Lukas | Laser Particle Analyser, Fritsch GmbH, Analysette 22 | 0.17 µm |
| 6 | Size fraction | Size fraction | % | Jonkers, Lukas | Laser Particle Analyser, Fritsch GmbH, Analysette 22 | 0.21 µm |
| 7 | Size fraction | Size fraction | % | Jonkers, Lukas | Laser Particle Analyser, Fritsch GmbH, Analysette 22 | 0.24 µm |
| 8 | Size fraction | Size fraction | % | Jonkers, Lukas | Laser Particle Analyser, Fritsch GmbH, Analysette 22 | 0.29 µm |
| 9 | Size fraction | Size fraction | % | Jonkers, Lukas | Laser Particle Analyser, Fritsch GmbH, Analysette 22 | 0.35 µm |
| 10 | Size fraction | Size fraction | % | Jonkers, Lukas | Laser Particle Analyser, Fritsch GmbH, Analysette 22 | 0.41 µm |
| 11 | Size fraction | Size fraction | % | Jonkers, Lukas | Laser Particle Analyser, Fritsch GmbH, Analysette 22 | 0.49 µm |
| 12 | Size fraction | Size fraction | % | Jonkers, Lukas | Laser Particle Analyser, Fritsch GmbH, Analysette 22 | 0.58 µm |
| 13 | Size fraction | Size fraction | % | Jonkers, Lukas | Laser Particle Analyser, Fritsch GmbH, Analysette 22 | 0.69 µm |
| 14 | Size fraction | Size fraction | % | Jonkers, Lukas | Laser Particle Analyser, Fritsch GmbH, Analysette 22 | 0.82 µm |
| 15 | Size fraction | Size fraction | % | Jonkers, Lukas | Laser Particle Analyser, Fritsch GmbH, Analysette 22 | 0.98 µm |
| 16 | Size fraction | Size fraction | % | Jonkers, Lukas | Laser Particle Analyser, Fritsch GmbH, Analysette 22 | 1.2 µm |
| 17 | Size fraction | Size fraction | % | Jonkers, Lukas | Laser Particle Analyser, Fritsch GmbH, Analysette 22 | 1.4 µm |
| 18 | Size fraction | Size fraction | % | Jonkers, Lukas | Laser Particle Analyser, Fritsch GmbH, Analysette 22 | 1.6 µm |
| 19 | Size fraction | Size fraction | % | Jonkers, Lukas | Laser Particle Analyser, Fritsch GmbH, Analysette 22 | 2.0 µm |
| 20 | Size fraction | Size fraction | % | Jonkers, Lukas | Laser Particle Analyser, Fritsch GmbH, Analysette 22 | 2.3 µm |
| 21 | Size fraction | Size fraction | % | Jonkers, Lukas | Laser Particle Analyser, Fritsch GmbH, Analysette 22 | 2.8 µm |
| 22 | Size fraction | Size fraction | % | Jonkers, Lukas | Laser Particle Analyser, Fritsch GmbH, Analysette 22 | 3.3 µm |
| 23 | Size fraction | Size fraction | % | Jonkers, Lukas | Laser Particle Analyser, Fritsch GmbH, Analysette 22 | 3.9 µm |
| 24 | Size fraction | Size fraction | % | Jonkers, Lukas | Laser Particle Analyser, Fritsch GmbH, Analysette 22 | 4.7 µm |
| 25 | Size fraction | Size fraction | % | Jonkers, Lukas | Laser Particle Analyser, Fritsch GmbH, Analysette 22 | 5.5 µm |
| 26 | Size fraction | Size fraction | % | Jonkers, Lukas | Laser Particle Analyser, Fritsch GmbH, Analysette 22 | 6.6 µm |
| 27 | Size fraction | Size fraction | % | Jonkers, Lukas | Laser Particle Analyser, Fritsch GmbH, Analysette 22 | 7.8 µm |
| 28 | Size fraction | Size fraction | % | Jonkers, Lukas | Laser Particle Analyser, Fritsch GmbH, Analysette 22 | 9.3 µm |
| 29 | Size fraction | Size fraction | % | Jonkers, Lukas | Laser Particle Analyser, Fritsch GmbH, Analysette 22 | 11.1 µm |
| 30 | Size fraction | Size fraction | % | Jonkers, Lukas | Laser Particle Analyser, Fritsch GmbH, Analysette 22 | 13.1 µm |
| 31 | Size fraction | Size fraction | % | Jonkers, Lukas | Laser Particle Analyser, Fritsch GmbH, Analysette 22 | 15.6 µm |
| 32 | Size fraction | Size fraction | % | Jonkers, Lukas | Laser Particle Analyser, Fritsch GmbH, Analysette 22 | 18.6 µm |
| 33 | Size fraction | Size fraction | % | Jonkers, Lukas | Laser Particle Analyser, Fritsch GmbH, Analysette 22 | 22.1 µm |
| 34 | Size fraction | Size fraction | % | Jonkers, Lukas | Laser Particle Analyser, Fritsch GmbH, Analysette 22 | 26.3 µm |
| 35 | Size fraction | Size fraction | % | Jonkers, Lukas | Laser Particle Analyser, Fritsch GmbH, Analysette 22 | 31.3 µm |
| 36 | Size fraction | Size fraction | % | Jonkers, Lukas | Laser Particle Analyser, Fritsch GmbH, Analysette 22 | 37.2 µm |
| 37 | Size fraction | Size fraction | % | Jonkers, Lukas | Laser Particle Analyser, Fritsch GmbH, Analysette 22 | 44.2 µm |
| 38 | Size fraction | Size fraction | % | Jonkers, Lukas | Laser Particle Analyser, Fritsch GmbH, Analysette 22 | 52.6 µm |
| 39 | Size fraction | Size fraction | % | Jonkers, Lukas | Laser Particle Analyser, Fritsch GmbH, Analysette 22 | 62.5 µm |
| 40 | Size fraction | Size fraction | % | Jonkers, Lukas | Laser Particle Analyser, Fritsch GmbH, Analysette 22 | 74.3 µm |
| 41 | Size fraction | Size fraction | % | Jonkers, Lukas | Laser Particle Analyser, Fritsch GmbH, Analysette 22 | 88.4 µm |
| 42 | Size fraction | Size fraction | % | Jonkers, Lukas | Laser Particle Analyser, Fritsch GmbH, Analysette 22 | 105 µm |
| 43 | Size fraction | Size fraction | % | Jonkers, Lukas | Laser Particle Analyser, Fritsch GmbH, Analysette 22 | 125 µm |
| 44 | Size fraction | Size fraction | % | Jonkers, Lukas | Laser Particle Analyser, Fritsch GmbH, Analysette 22 | 149 µm |
| 45 | Size fraction | Size fraction | % | Jonkers, Lukas | Laser Particle Analyser, Fritsch GmbH, Analysette 22 | 177 µm |
| 46 | Size fraction | Size fraction | % | Jonkers, Lukas | Laser Particle Analyser, Fritsch GmbH, Analysette 22 | 210 µm |
| 47 | Size fraction | Size fraction | % | Jonkers, Lukas | Laser Particle Analyser, Fritsch GmbH, Analysette 22 | 250 µm |
| 48 | Size fraction | Size fraction | % | Jonkers, Lukas | Laser Particle Analyser, Fritsch GmbH, Analysette 22 | 297 µm |
| 49 | Size fraction | Size fraction | % | Jonkers, Lukas | Laser Particle Analyser, Fritsch GmbH, Analysette 22 | 354 µm |
| 50 | Size fraction | Size fraction | % | Jonkers, Lukas | Laser Particle Analyser, Fritsch GmbH, Analysette 22 | 420 µm |
| 51 | Size fraction | Size fraction | % | Jonkers, Lukas | Laser Particle Analyser, Fritsch GmbH, Analysette 22 | 500 µm |
License:
Creative Commons Attribution 3.0 Unported (CC-BY-3.0)
Size:
4750 data points
Download Data
View dataset as HTML (shows only first 2000 rows)
