<?xml version="1.0" encoding="UTF-8"?><md:MetaData xmlns:md="http://www.pangaea.de/MetaData" version="2024-07-19">
<md:citation id="dataset838438">
<md:author id="dataset.author34022">
<md:lastName>Holtappels</md:lastName>
<md:firstName>Moritz</md:firstName>
<md:eMail>moritz.holtappels@awi.de</md:eMail>
<md:URI>https://www.awi.de/en/about-us/organisation/staff/single-view/moritz-holtappels.html</md:URI>
<md:orcid>0000-0003-3682-1903</md:orcid>
</md:author>
<md:author id="dataset.author53212">
<md:lastName>Noss</md:lastName>
<md:firstName>Christian</md:firstName>
</md:author>
<md:author id="dataset.author53213">
<md:lastName>Hancke</md:lastName>
<md:firstName>Kasper</md:firstName>
</md:author>
<md:author id="dataset.author46324">
<md:lastName>Cathalot</md:lastName>
<md:firstName>Cecile</md:firstName>
<md:eMail>cecile.cathalot@ifremer.fr</md:eMail>
<md:orcid>0000-0002-0868-7201</md:orcid>
</md:author>
<md:author id="dataset.author53214">
<md:lastName>McGinnis</md:lastName>
<md:firstName>Daniel F</md:firstName>
<md:eMail>danielm@biology.sdu.dk</md:eMail>
<md:orcid>0000-0002-6163-4299</md:orcid>
</md:author>
<md:author id="dataset.author38540">
<md:lastName>Lorke</md:lastName>
<md:firstName>Andreas</md:firstName>
<md:orcid>0000-0001-5533-1817</md:orcid>
</md:author>
<md:author id="dataset.author10758">
<md:lastName>Glud</md:lastName>
<md:firstName>Ronnie N</md:firstName>
<md:eMail>rnglud@biology.sdu.dk</md:eMail>
<md:orcid>0000-0002-7069-893X</md:orcid>
</md:author>
<md:year>2014</md:year>
<md:title>(Exp. 2) Artificial oxygen fluxes measured by the eddy correlation method using stirring-sensitive oxygen microsensor in a flume experiment</md:title>
<md:type id="dataset.reftype10" includeInCitation="true">dataset</md:type>
<md:URI>https://doi.org/10.1594/PANGAEA.838438</md:URI>
<md:dateTime>2014-11-11T09:14:48</md:dateTime>
<md:parentURI>https://doi.org/10.1594/PANGAEA.838341</md:parentURI>
</md:citation>
<md:reference dataciteRelType="References" group="210" id="ref65946" relationType="Related to" relationTypeId="12">
<md:author id="ref65946.author34022">
<md:lastName>Holtappels</md:lastName>
<md:firstName>Moritz</md:firstName>
<md:eMail>moritz.holtappels@awi.de</md:eMail>
<md:URI>https://www.awi.de/en/about-us/organisation/staff/single-view/moritz-holtappels.html</md:URI>
<md:orcid>0000-0003-3682-1903</md:orcid>
</md:author>
<md:author id="ref65946.author53212">
<md:lastName>Noss</md:lastName>
<md:firstName>Christian</md:firstName>
</md:author>
<md:author id="ref65946.author53213">
<md:lastName>Hancke</md:lastName>
<md:firstName>Kasper</md:firstName>
</md:author>
<md:author id="ref65946.author46324">
<md:lastName>Cathalot</md:lastName>
<md:firstName>Cecile</md:firstName>
<md:eMail>cecile.cathalot@ifremer.fr</md:eMail>
<md:orcid>0000-0002-0868-7201</md:orcid>
</md:author>
<md:author id="ref65946.author53214">
<md:lastName>McGinnis</md:lastName>
<md:firstName>Daniel F</md:firstName>
<md:eMail>danielm@biology.sdu.dk</md:eMail>
<md:orcid>0000-0002-6163-4299</md:orcid>
</md:author>
<md:author id="ref65946.author38540">
<md:lastName>Lorke</md:lastName>
<md:firstName>Andreas</md:firstName>
<md:orcid>0000-0001-5533-1817</md:orcid>
</md:author>
<md:author id="ref65946.author10758">
<md:lastName>Glud</md:lastName>
<md:firstName>Ronnie N</md:firstName>
<md:eMail>rnglud@biology.sdu.dk</md:eMail>
<md:orcid>0000-0002-7069-893X</md:orcid>
</md:author>
<md:year>2015</md:year>
<md:title>Aquatic Eddy Correlation: Quantifying the Artificial Flux Caused by Stirring-Sensitive O2 Sensors</md:title>
<md:type id="ref65946.reftype1">journal article</md:type>
<md:source id="ref65946.journal13007" relatedTermIds="34013" type="journal">PLoS ONE</md:source>
<md:volume>10(1)</md:volume>
<md:URI>https://doi.org/10.1371/journal.pone.0116564</md:URI>
<md:pages>e0116564</md:pages>
</md:reference>
<md:extent>
<md:topoType id="topotype1">not specified</md:topoType>
</md:extent>
<md:project id="project4011" type="National DFG">
<md:label>MARUM</md:label>
<md:name>Center for Marine Environmental Sciences</md:name>
<md:URI>https://www.marum.de/en/</md:URI>
<md:institution id="project4011.inst277">
<md:name>MARUM - Center for Marine Environmental Sciences, University Bremen</md:name>
<md:optionalName>MARUM</md:optionalName>
<md:URI>http://www.marum.de/</md:URI>
<md:ROR>https://ror.org/04ers2y35</md:ROR>
</md:institution>
</md:project>
<md:event id="event2752500">
<md:label>Flume_Eddy_2013_EXP_2</md:label>
<md:method id="event2752500.method7423">
<md:name>Experiment</md:name>
<md:optionalName>EXP</md:optionalName>
</md:method>
<md:comment>Flume experiments were conducted in February 2013 at the Institute for Environmental Sciences, University of Koblenz-Landau, Landau, Germany</md:comment>
</md:event>
<md:size unit="data points">8880</md:size>
<md:license id="license101">
<md:label>CC-BY-3.0</md:label>
<md:name>Creative Commons Attribution 3.0 Unported</md:name>
<md:URI>https://creativecommons.org/licenses/by/3.0/</md:URI>
</md:license>
<md:comment>Flume experiments were conducted in February 2013 at the Institute for Environmental Sciences, University of Koblenz-Landau Landau. Experiments were performed in a closed oval-shaped acrylic glass flume with cross-sectional width of 4 cm and height of 10 cm and total length of 54 cm. The fluid flow was induced by a propeller driven by a motor and mean flow velocities of up to 20 cm s-1 were generated by applying voltages between 0 V and 4 V DC. The flume was completely sealed with an acrylic glass cover. Oxygen sensors were inserted through rubber seal fittings and allowed positioning the sensors with inclinations to the main flow direction of ~60°, ~95° and ~135°. A Clark type electrochemical O2 microsensor with a low stirring sensitivity (0.7%) was tested and a fast-responding needle-type O2 optode (PyroScience GmbH, Germany) was used as reference as optodes should not be stirring sensitive. 
Instantaneous three-dimensional flow velocities were measured at 7.4 Hz using stereoscopic particle image velocimetry (PIV). The velocity at the sensor tip was extracted. The correlation of the fluctuating O2 sensor signals and the fluctuating velocities was quantified with a cross-correlation analysis. A significant cross-correlation is equivalent to a significant artificial flux. 
For a total of 18 experiments the flow velocity was adjusted between 1.7 and 19.2 cm s-1, and 3 different orientations of the electrochemical sensor were tested with inclination angles of ~60°, ~95° and ~135° with respect to the main flow direction. In experiments 16-18, wavelike flow was induced, whereas in all other experiments the motor was driven by constant voltages.</md:comment>
<md:matrixColumn col="0" format="#.000E0" id="col0.ds12555653" source="data" type="numeric">
<md:parameter id="col0.ds12555653.param107870">
<md:name>Flow velocity, water</md:name>
<md:shortName>Vel water</md:shortName>
<md:unit>m/s</md:unit>
<md:term endOffset="20" fragment="2" id="col0.ds12555653.param107870.term2606205" semanticURI="http://purl.obolibrary.org/obo/CHEBI_15377" startOffset="15" terminologyId="16" terminologyLabel="ChEBI">
<md:name>water</md:name>
<md:URI>http://purl.obolibrary.org/obo/CHEBI_15377</md:URI>
</md:term>
<md:term id="col0.ds12555653.param107870.term43876" semanticURI="http://qudt.org/1.1/vocab/quantity#LinearVelocity" terminologyId="13" terminologyLabel="PAN-Quantity">
<md:name>Linear Velocity</md:name>
<md:URI>http://dbpedia.org/resource/Velocity</md:URI>
</md:term>
</md:parameter>
<md:method id="col0.ds12555653.method8671">
<md:name>Particle Image Velocimetry (PIV)</md:name>
<md:optionalName>PIV</md:optionalName>
<md:URI>https://en.wikipedia.org/wiki/Particle_image_velocimetry</md:URI>
</md:method>
<md:PI id="col0.ds12555653.pi34022">
<md:lastName>Holtappels</md:lastName>
<md:firstName>Moritz</md:firstName>
<md:eMail>moritz.holtappels@awi.de</md:eMail>
<md:URI>https://www.awi.de/en/about-us/organisation/staff/single-view/moritz-holtappels.html</md:URI>
<md:orcid>0000-0003-3682-1903</md:orcid>
</md:PI>
<md:comment>longitudinal velocity</md:comment>
<md:caption>Vel water [m/s] (longitudinal velocity, Partic...)</md:caption>
</md:matrixColumn>
<md:matrixColumn col="1" format="#.000E0" id="col1.ds12555654" source="data" type="numeric">
<md:parameter id="col1.ds12555654.param107870">
<md:name>Flow velocity, water</md:name>
<md:shortName>Vel water</md:shortName>
<md:unit>m/s</md:unit>
<md:term endOffset="20" fragment="2" id="col1.ds12555654.param107870.term2606205" semanticURI="http://purl.obolibrary.org/obo/CHEBI_15377" startOffset="15" terminologyId="16" terminologyLabel="ChEBI">
<md:name>water</md:name>
<md:URI>http://purl.obolibrary.org/obo/CHEBI_15377</md:URI>
</md:term>
<md:term id="col1.ds12555654.param107870.term43876" semanticURI="http://qudt.org/1.1/vocab/quantity#LinearVelocity" terminologyId="13" terminologyLabel="PAN-Quantity">
<md:name>Linear Velocity</md:name>
<md:URI>http://dbpedia.org/resource/Velocity</md:URI>
</md:term>
</md:parameter>
<md:method id="col1.ds12555654.method8671">
<md:name>Particle Image Velocimetry (PIV)</md:name>
<md:optionalName>PIV</md:optionalName>
<md:URI>https://en.wikipedia.org/wiki/Particle_image_velocimetry</md:URI>
</md:method>
<md:PI id="col1.ds12555654.pi34022">
<md:lastName>Holtappels</md:lastName>
<md:firstName>Moritz</md:firstName>
<md:eMail>moritz.holtappels@awi.de</md:eMail>
<md:URI>https://www.awi.de/en/about-us/organisation/staff/single-view/moritz-holtappels.html</md:URI>
<md:orcid>0000-0003-3682-1903</md:orcid>
</md:PI>
<md:comment>vertical velocity</md:comment>
<md:caption>Vel water [m/s] (vertical velocity, Particle I...)</md:caption>
</md:matrixColumn>
<md:matrixColumn col="2" format="#.000E0" id="col2.ds12555655" source="data" type="numeric">
<md:parameter id="col2.ds12555655.param107870">
<md:name>Flow velocity, water</md:name>
<md:shortName>Vel water</md:shortName>
<md:unit>m/s</md:unit>
<md:term endOffset="20" fragment="2" id="col2.ds12555655.param107870.term2606205" semanticURI="http://purl.obolibrary.org/obo/CHEBI_15377" startOffset="15" terminologyId="16" terminologyLabel="ChEBI">
<md:name>water</md:name>
<md:URI>http://purl.obolibrary.org/obo/CHEBI_15377</md:URI>
</md:term>
<md:term id="col2.ds12555655.param107870.term43876" semanticURI="http://qudt.org/1.1/vocab/quantity#LinearVelocity" terminologyId="13" terminologyLabel="PAN-Quantity">
<md:name>Linear Velocity</md:name>
<md:URI>http://dbpedia.org/resource/Velocity</md:URI>
</md:term>
</md:parameter>
<md:method id="col2.ds12555655.method8671">
<md:name>Particle Image Velocimetry (PIV)</md:name>
<md:optionalName>PIV</md:optionalName>
<md:URI>https://en.wikipedia.org/wiki/Particle_image_velocimetry</md:URI>
</md:method>
<md:PI id="col2.ds12555655.pi34022">
<md:lastName>Holtappels</md:lastName>
<md:firstName>Moritz</md:firstName>
<md:eMail>moritz.holtappels@awi.de</md:eMail>
<md:URI>https://www.awi.de/en/about-us/organisation/staff/single-view/moritz-holtappels.html</md:URI>
<md:orcid>0000-0003-3682-1903</md:orcid>
</md:PI>
<md:comment>transversal velocity</md:comment>
<md:caption>Vel water [m/s] (transversal velocity, Particl...)</md:caption>
</md:matrixColumn>
<md:matrixColumn col="3" format="##0.00" id="col3.ds12555656" source="data" type="numeric">
<md:parameter id="col3.ds12555656.param754">
<md:name>Oxygen</md:name>
<md:shortName>O2</md:shortName>
<md:unit>µmol/l</md:unit>
<md:term endOffset="6" fragment="1" id="col3.ds12555656.param754.term38494" semanticURI="http://purl.obolibrary.org/obo/CHEBI_25805" startOffset="0" terminologyId="18" terminologyLabel="PAN-MicroBio">
<md:name>oxygen</md:name>
<md:optionalName>O</md:optionalName>
<md:URI>https://www.ebi.ac.uk/chebi/searchId.do?chebiId=CHEBI:25805</md:URI>
</md:term>
<md:term id="col3.ds12555656.param754.term44030" terminologyId="13" terminologyLabel="PAN-Quantity">
<md:name>Molar Concentration</md:name>
</md:term>
</md:parameter>
<md:method id="col3.ds12555656.method8672">
<md:name>Clark type electrochemical Oxygen microsensor</md:name>
<md:term id="col3.ds12555656.method8672.term67625" terminologyId="3" terminologyLabel="PAN-M&amp;D">
<md:name>Chemical property sensors</md:name>
</md:term>
<md:term id="col3.ds12555656.method8672.term2299463" semanticURI="SDN:L05::351" terminologyId="21" terminologyLabel="NERC-L05-L22">
<md:name>dissolved gas sensors</md:name>
<md:URI>http://vocab.nerc.ac.uk/collection/L05/current/351/</md:URI>
</md:term>
</md:method>
<md:PI id="col3.ds12555656.pi34022">
<md:lastName>Holtappels</md:lastName>
<md:firstName>Moritz</md:firstName>
<md:eMail>moritz.holtappels@awi.de</md:eMail>
<md:URI>https://www.awi.de/en/about-us/organisation/staff/single-view/moritz-holtappels.html</md:URI>
<md:orcid>0000-0003-3682-1903</md:orcid>
</md:PI>
<md:caption>O2 [µmol/l] (Clark type electrochemical Ox...)</md:caption>
</md:matrixColumn>
<md:keywords>
<md:techKeyword type="autoGenerated">citable</md:techKeyword>
<md:techKeyword type="autoGenerated">author10758</md:techKeyword>
<md:techKeyword type="autoGenerated">author34022</md:techKeyword>
<md:techKeyword type="autoGenerated">author38540</md:techKeyword>
<md:techKeyword type="autoGenerated">author46324</md:techKeyword>
<md:techKeyword type="autoGenerated">author53212</md:techKeyword>
<md:techKeyword type="autoGenerated">author53213</md:techKeyword>
<md:techKeyword type="autoGenerated">author53214</md:techKeyword>
<md:techKeyword type="autoGenerated">event2752500</md:techKeyword>
<md:techKeyword type="autoGenerated">inst277</md:techKeyword>
<md:techKeyword type="autoGenerated">journal13007</md:techKeyword>
<md:techKeyword type="autoGenerated">license101</md:techKeyword>
<md:techKeyword type="autoGenerated">method7423</md:techKeyword>
<md:techKeyword type="autoGenerated">method8671</md:techKeyword>
<md:techKeyword type="autoGenerated">method8672</md:techKeyword>
<md:techKeyword type="autoGenerated">param107870</md:techKeyword>
<md:techKeyword type="autoGenerated">param754</md:techKeyword>
<md:techKeyword type="autoGenerated">pi34022</md:techKeyword>
<md:techKeyword type="autoGenerated">project4011</md:techKeyword>
<md:techKeyword type="autoGenerated">ref65946</md:techKeyword>
<md:techKeyword type="autoGenerated">term2299463</md:techKeyword>
<md:techKeyword type="autoGenerated">term2606205</md:techKeyword>
<md:techKeyword type="autoGenerated">term38494</md:techKeyword>
<md:techKeyword type="autoGenerated">term43876</md:techKeyword>
<md:techKeyword type="autoGenerated">term44030</md:techKeyword>
<md:techKeyword type="autoGenerated">term67625</md:techKeyword>
<md:techKeyword type="autoGenerated">topotype1</md:techKeyword>
</md:keywords>
<md:technicalInfo>
<md:entry key="xmlLastModified" value="2025-05-23T08:02:50Z"/>
<md:entry key="lastModified" value="2015-04-10T10:46:30"/>
<md:entry key="filename" value="Flume_Eddy_2013_EXP_2"/>
<md:entry key="mimeType" value="text/tab-separated-values"/>
<md:entry key="status" value="published"/>
<md:entry key="status_num" value="4"/>
<md:entry key="DOIRegistryStatus" value="registered"/>
<md:entry key="DOIRegistryStatus_num" value="4"/>
<md:entry key="DOIRegistrationDate" value="2015-03-03T03:03:06"/>
<md:entry key="hierarchyLevel" value="child"/>
<md:entry key="loginOption" value="unrestricted"/>
<md:entry key="loginOption_num" value="1"/>
</md:technicalInfo>
</md:MetaData>