Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

Kaul, Norbert; Hensen, Christian (2014): Heat flow data at station H1202P10 [dataset]. Department of Geosciences, Bremen University, PANGAEA, https://doi.org/10.1594/PANGAEA.837395, In: Kaul, N; Hensen, C (2014): Heat flow measurements on METEOR cruise M86/5 [dataset publication series]. Department of Geosciences, Bremen University, PANGAEA, https://doi.org/10.1594/PANGAEA.830805

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Related to:
Hensen, Christian (2014): TransFlux Tracing for active dewatering sites along deep-reaching transform faults in the western Gulf of Cadiz - Cruise No. M86/5 - February 23 - March 16, 2012 - Palma de Mallorca (Spain) - Lisbon (Portugal). METEOR-Berichte, DFG-Senatskommission für Ozeanographie, M86/5, 70 pp, https://doi.org/10.2312/cr_m86_5
Coverage:
Latitude: 35.774630 * Longitude: -10.191520
Date/Time Start: 2012-03-02T05:18:00 * Date/Time End: 2012-03-02T05:34:00
Minimum DEPTH, sediment/rock: -1.96 m * Maximum DEPTH, sediment/rock: 3.23 m
Event(s):
H1202P10 (M86/5_26-10) * Latitude: 35.774630 * Longitude: -10.191520 * Date/Time Start: 2012-03-02T05:18:00 * Date/Time End: 2012-03-02T05:34:00 * Elevation: -4641.0 m * Location: South Atlantic Ocean * Campaign: M86/5 * Basis: Meteor (1986) * Method/Device: Heat-Flow probe (HF)
Comment:
Depth, sediment = Penetration depth
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
DEPTH, sediment/rockDepth sedmGeocode
Sample code/labelSample labelKaul, Norbert
Depth, relativeDepth relmKaul, Norbert
Temperature, relativeT relKKaul, NorbertHeat flow probe
Conductivity, thermalkW/m/KKaul, NorbertCalculatedassumed
Integrated thermal resistanceITRm2 K/WKaul, NorbertCalculatedBullard depth
Size:
105 data points

Data

Download dataset as tab-delimited text — use the following character encoding:


Depth sed [m]

Sample label

Depth rel [m]

T rel [K]

k [W/m/K]

ITR [m2 K/W]
-1.96210.0000.03241.34-1.962
-1.70200.2590.03271.34-1.703
-1.44190.5190.03201.34-1.444
-1.18180.7780.03191.34-1.184
-0.92171.0380.03201.34-0.925
-0.67161.2970.03131.34-0.665
-0.41151.5560.03141.34-0.406
-0.15141.8160.03201.34-0.147
0.11132.0750.06621.340.084
0.37122.3350.07841.340.278
0.63112.5940.09871.340.471
0.89102.8540.05671.340.665
1.1593.1130.07821.340.859
1.4183.3720.09291.341.052
1.6773.6320.08441.341.246
1.9363.8910.10841.341.439
2.1954.1510.12851.341.633
2.4544.4100.13651.341.827
2.7134.6690.14061.342.020
2.9724.9290.12721.342.214
3.2315.1880.15071.342.407