Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

WOCE Hydrographic Programme, WHP (2002): Hydrochemistry measured on water bottle samples during Charles Darwin cruise 74AB62A [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.837165

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Related to:
WOCE (2002): World Ocean Circulation Experiment, Global Data, Version 3.0. WOCE International Project Office, WOCE Report, Southampton, UK; published by U.S. National Oceanographic Data Center, Silver Spring, 180/02, DVD-ROM
Coverage:
Median Latitude: 63.169584 * Median Longitude: -4.927272 * South-bound Latitude: 62.265000 * West-bound Longitude: -6.298500 * North-bound Latitude: 63.962800 * East-bound Longitude: -3.535800
Date/Time Start: 1991-09-12T16:52:00 * Date/Time End: 1991-09-23T10:28:00
Minimum DEPTH, water: 1.29 m * Maximum DEPTH, water: 3293.66 m
Event(s):
74AB62A/47694-1  * Latitude: 63.957700 * Longitude: -4.452700 * Date/Time: 1991-09-12T16:52:00 * Elevation: -3166.0 m * Location: Norwegian Sea * Campaign: CD62A (74AB62A) * Basis: Charles Darwin * Method/Device: CTD/Rosette (CTD-RO)
74AB62A/47696-1  * Latitude: 63.962700 * Longitude: -3.535800 * Date/Time: 1991-09-12T21:55:00 * Elevation: -3005.0 m * Location: Norwegian Sea * Campaign: CD62A (74AB62A) * Basis: Charles Darwin * Method/Device: CTD/Rosette (CTD-RO)
74AB62A/47698-1  * Latitude: 63.636700 * Longitude: -3.847300 * Date/Time: 1991-09-13T02:36:00 * Elevation: -2686.0 m * Location: Norwegian Sea * Campaign: CD62A (74AB62A) * Basis: Charles Darwin * Method/Device: CTD/Rosette (CTD-RO)
Comment:
For definition of quality flags see hdl:10013/epic.31518.d001
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
Event labelEvent
Date/Time of eventDate/Time
Latitude of eventLatitude
Longitude of eventLongitude
Elevation of eventElevationm
DEPTH, waterDepth watermGeocode
Pressure, waterPressdbarCTD
Temperature, waterTemp°CCTDITS-90
SalinitySalCTDPSS-78
10 SalinitySalSalinometer, inductivePSS-78
11 Sample IDSample ID
12 Bottle numberBottle
Size:
736 data points

Data

Download dataset as tab-delimited text — use the following character encoding:


Event

Date/Time

Latitude

Longitude

Elevation [m]

Depth water [m]

Press [dbar]
(CTD)

Temp [°C]
(ITS-90, CTD)

Sal
(PSS-78, CTD)
10 
Sal
(PSS-78, Salinometer, inductive)
11 
Sample ID
12 
Bottle
74AB62A/47694-1 1991-09-12T16:5263.9577-4.4527-31661.481.59.6170?34.793034.903067054
74AB62A/47694-11991-09-12T16:5263.9577-4.4527-3166265.53268.42.5740?34.940034.945057004
74AB62A/47694-11991-09-12T16:5263.9577-4.4527-31661008.861021.5-0.6060?34.907034.904047003
74AB62A/47694-11991-09-12T16:5263.9577-4.4527-31661485.841506.1-0.8250?34.911034.909037002
74AB62A/47694-11991-09-12T16:5263.9577-4.4527-31662001.622031.3-0.899034.908034.907027059
74AB62A/47694-11991-09-12T16:5263.9577-4.4527-31663134.563189.3-0.831034.908034.907017001
74AB62A/47696-1 1991-09-12T21:5563.9627-3.5358-30054.754.89.8160?34.783034.801067050
74AB62A/47696-11991-09-12T21:5563.9627-3.5358-3005159.71161.43.1450?34.907034.944057055
74AB62A/47696-11991-09-12T21:5563.9627-3.5358-3005968.16980.2-0.5510?34.907034.905047009
74AB62A/47696-11991-09-12T21:5563.9627-3.5358-30051487.121507.4-0.8110?34.911034.909037008
74AB62A/47696-11991-09-12T21:5563.9627-3.5358-30051997.502027.1-0.886034.909034.908027007
74AB62A/47696-11991-09-12T21:5563.9627-3.5358-30052973.593024.4-0.8430?34.908034.909017006
74AB62A/47698-1 1991-09-13T02:3663.6367-3.8473-268614.2514.49.8110?34.886034.909067016
74AB62A/47698-11991-09-13T02:3663.6367-3.8473-268664.0464.77.7900?35.162035.198057015
74AB62A/47698-11991-09-13T02:3663.6367-3.8473-2686998.831011.3-0.565034.917034.915047014
74AB62A/47698-11991-09-13T02:3663.6367-3.8473-26861494.431514.8-0.8090?34.915034.909037013
74AB62A/47698-11991-09-13T02:3663.6367-3.8473-26861995.882025.4-0.8900?34.908034.908027012
74AB62A/47698-11991-09-13T02:3663.6367-3.8473-26862628.662671.4-0.8680?34.901034.951017011
74AB62A/47700-1 1991-09-13T06:5563.3117-4.0862-27285.155.29.021034.728034.817067021
74AB62A/47700-11991-09-13T06:5563.3117-4.0862-2728703.23711.5-0.4410?34.905034.903057020
74AB62A/47700-11991-09-13T06:5563.3117-4.0862-27281007.261019.8-0.6890?34.910034.908047051
74AB62A/47700-11991-09-13T06:5563.3117-4.0862-27281502.371522.8-0.8550?34.910034.908037019
74AB62A/47700-11991-09-13T06:5563.3117-4.0862-27281988.032017.3-0.9030?34.908034.907027018
74AB62A/47700-11991-09-13T06:5563.3117-4.0862-27282564.122605.3-0.874034.907034.908017017
74AB62A/47702-1 1991-09-13T11:3262.9830-4.3587-21461.291.39.4000?34.726034.733057025
74AB62A/47702-11991-09-13T11:3262.9830-4.3587-2146455.91461.0-0.1500?34.902034.899047024
74AB62A/47702-11991-09-13T11:3262.9830-4.3587-2146917.29928.5-0.5480?34.908034.906037023
74AB62A/47702-11991-09-13T11:3262.9830-4.3587-21461514.211534.8-0.8080?34.908034.908027022
74AB62A/47702-11991-09-13T11:3262.9830-4.3587-21462093.132124.4-0.8820?34.908034.908017045
74AB62A/47704-1 1991-09-13T15:5162.6465-4.6325-6933.173.28.9880?34.780034.790047046
74AB62A/47704-11991-09-13T15:5162.6465-4.6325-693208.89211.17.976035.236035.236037028
74AB62A/47704-11991-09-13T15:5162.6465-4.6325-693502.84508.51.5660?34.896034.896027027
74AB62A/47704-11991-09-13T15:5162.6465-4.6325-693648.67656.2-0.3270?34.905034.904017056
74AB62A/47706-1 1991-09-13T20:0262.2897-4.9532-22018.3118.510.6410?35.158035.159037030
74AB62A/47706-11991-09-13T20:0262.2897-4.9532-220126.78128.18.8660?35.247035.248027029
74AB62A/47706-11991-09-13T20:0262.2897-4.9532-220190.10192.17.5960?35.206035.205017060
74AB62A/47708-1 1991-09-13T23:1362.6443-5.2160-5632.772.810.7260?35.155035.155037033
74AB62A/47708-11991-09-13T23:1362.6443-5.2160-563245.28247.97.9200?35.232035.232027032
74AB62A/47708-11991-09-13T23:1362.6443-5.2160-563538.09544.20.3980?34.900034.902017057
74AB62A/47710-1 1991-09-14T02:1562.9770-5.4453-1757345.72349.52.6020?34.939034.911047036
74AB62A/47710-11991-09-14T02:1562.9770-5.4453-1757748.92757.8-0.2410?34.902034.901037035
74AB62A/47710-11991-09-14T02:1562.9770-5.4453-1757978.68990.8-0.5000?34.907034.905027034
74AB62A/47710-11991-09-14T02:1562.9770-5.4453-17571698.431722.3-0.8780?34.909034.908017058
74AB62A/47712-1 1991-09-14T06:2163.3155-5.757865.5266.29.0430?34.887034.728057039
74AB62A/47712-11991-09-14T06:2163.3155-5.7578605.80612.80.0530?34.890034.730047048
74AB62A/47712-11991-09-14T06:2163.3155-5.75781052.651065.9-0.5270?34.902034.897037038
74AB62A/47712-11991-09-14T06:2163.3155-5.75781463.401483.2-0.742034.905034.908027053
74AB62A/47712-11991-09-14T06:2163.3155-5.75782127.342159.4-0.8710?34.909034.908017037
74AB62A/47714-1 1991-09-14T10:2663.6333-6.0055-21111.982.09.3130?34.906034.913057044
74AB62A/47714-11991-09-14T10:2663.6333-6.0055-2111349.66353.53.1110?34.952034.966047043
74AB62A/47714-11991-09-14T10:2663.6333-6.0055-2111939.11950.7-0.4520?34.906034.912037042
74AB62A/47714-11991-09-14T10:2663.6333-6.0055-21111470.741490.7-0.7630?34.909034.906027041
74AB62A/47714-11991-09-14T10:2663.6333-6.0055-21112067.182098.1-0.8620?34.908034.909017040
74AB62A/47716-1 1991-09-19T12:0862.2650-5.0178-1924.264.310.4020?35.202035.201036065
74AB62A/47716-11991-09-19T12:0862.2650-5.0178-192121.15122.49.2420?35.242035.242026070
74AB62A/47716-11991-09-19T12:0862.2650-5.0178-192169.82171.68.7460?35.244035.246015601
74AB62A/47718-1 1991-09-19T15:5262.6483-5.2098-5732.472.59.9590?35.155035.149046072
74AB62A/47718-11991-09-19T15:5262.6483-5.2098-573248.94251.67.9390?35.235035.235036049
74AB62A/47718-11991-09-19T15:5262.6483-5.2098-573530.49536.50.0840?34.902034.903026071
74AB62A/47718-11991-09-19T15:5262.6483-5.2098-573550.24556.50.0040?34.901034.903016058
74AB62A/47720-1 1991-09-19T19:2062.9755-5.4667-17171.982.010.0510?35.042035.036046076
74AB62A/47720-11991-09-19T19:2062.9755-5.4667-1717225.89228.34.9330?35.026035.027036075
74AB62A/47720-11991-09-19T19:2062.9755-5.4667-17171003.811016.3-0.5050?34.910034.907026074
74AB62A/47720-11991-09-19T19:2062.9755-5.4667-17171485.661505.8-0.7140?34.910034.909016073
74AB62A/47722-1 1991-09-20T00:0263.3107-5.7600-216159.3960.08.9610?34.992035.007066079
74AB62A/47722-11991-09-20T00:0263.3107-5.7600-2161289.27292.44.5580?34.964034.952056078
74AB62A/47722-11991-09-20T00:0263.3107-5.7600-2161668.48676.30.0690?34.900034.898046087
74AB62A/47722-11991-09-20T00:0263.3107-5.7600-2161967.32979.3-0.4150?34.906034.904036008
74AB62A/47722-11991-09-20T00:0263.3107-5.7600-21611456.711476.4-0.7130?34.908034.907026050
74AB62A/47722-11991-09-20T00:0263.3107-5.7600-21612033.402063.6-0.8730?34.908034.907016059
74AB62A/47724-1 1991-09-20T04:3163.6397-5.9997-21375.645.78.1490?34.722034.732066088
74AB62A/47724-11991-09-20T04:3163.6397-5.9997-2137414.78419.40.5960?34.904034.901056066
74AB62A/47724-11991-09-20T04:3163.6397-5.9997-2137998.531011.0-0.588034.909034.906046060
74AB62A/47724-11991-09-20T04:3163.6397-5.9997-21371488.431508.7-0.7990?34.908034.907036081
74AB62A/47724-11991-09-20T04:3163.6397-5.9997-21371977.242006.4-0.8610?34.907034.907026051
74AB62A/47724-11991-09-20T04:3163.6397-5.9997-21372072.582103.6-0.8660#34.907034.908016080
74AB62A/47726-1 1991-09-20T13:4063.9422-6.2985-31456.146.27.8970?34.700034.729066086
74AB62A/47726-11991-09-20T13:4063.9422-6.2985-3145204.42206.63.0470?34.955034.965056018
74AB62A/47726-11991-09-20T13:4063.9422-6.2985-3145962.25974.2-0.5490?34.909034.905046017
74AB62A/47726-11991-09-20T13:4063.9422-6.2985-31451484.961505.2-0.813034.911034.909036052
74AB62A/47726-11991-09-20T13:4063.9422-6.2985-31451956.991985.8-0.8850?34.911034.909026016
74AB62A/47726-11991-09-20T13:4063.9422-6.2985-31453119.053173.4-0.8320?34.909034.909016015
74AB62A/47728-1 1991-09-20T18:5763.9628-5.3848-332132.3732.78.3460?34.704034.711066023
74AB62A/47728-11991-09-20T18:5763.9628-5.3848-3321207.88210.13.0360?34.952034.951056022
74AB62A/47728-11991-09-20T18:5763.9628-5.3848-3321995.261007.7-0.6100?34.911034.907046053
74AB62A/47728-11991-09-20T18:5763.9628-5.3848-33211985.732015.1-0.898034.910034.909036021
74AB62A/47728-11991-09-20T18:5763.9628-5.3848-33212988.143039.3-0.844034.910034.909026020
74AB62A/47728-11991-09-20T18:5763.9628-5.3848-33213293.663352.4-0.8170?34.910034.911016019
74AB62A/47730-1 1991-09-21T06:0963.6360-3.8442-26911.681.734.798066027
74AB62A/47730-11991-09-21T06:0963.6360-3.8442-2691209.66211.93.0790?34.929034.932056026
74AB62A/47730-11991-09-21T06:0963.6360-3.8442-26911018.831031.6-0.5950?34.908034.906046054
74AB62A/47730-11991-09-21T06:0963.6360-3.8442-26911510.161530.8-0.8400?34.910034.908036025
74AB62A/47730-11991-09-21T06:0963.6360-3.8442-26912017.462047.4-0.9010?34.908034.908026062
74AB62A/47730-11991-09-21T06:0963.6360-3.8442-26912667.682711.3-0.867034.908034.908016024
74AB62A/47732-1 1991-09-21T23:2962.9773-4.3647-213828.6128.98.7500?34.783034.785056055
74AB62A/47732-11991-09-21T23:2962.9773-4.3647-2138514.67520.50.0550?34.900034.897046063
74AB62A/47732-11991-09-21T23:2962.9773-4.3647-21381020.561033.3-0.5800?34.909034.908036028
74AB62A/47732-11991-09-21T23:2962.9773-4.3647-21381504.341524.8-0.8180?34.910034.908026067
74AB62A/47732-11991-09-21T23:2962.9773-4.3647-21382100.432131.9-0.8810?34.908034.908016068
74AB62A/47734-1 1991-09-22T05:5862.6487-4.6308-69745.3445.89.7450?35.178035.119046032
74AB62A/47734-11991-09-22T05:5862.6487-4.6308-697148.55150.18.3970?35.257035.258036031
74AB62A/47734-11991-09-22T05:5862.6487-4.6308-697595.66602.5-0.2160?34.900034.902026030
74AB62A/47734-11991-09-22T05:5862.6487-4.6308-697678.58686.5-0.4100?34.904034.904016029
74AB62A/47736-1 1991-09-22T10:4862.2890-4.9273-2243.273.310.285035.206035.202036034
74AB62A/47736-11991-09-22T10:4862.2890-4.9273-22450.1950.710.2930?35.204035.204026085
74AB62A/47736-11991-09-22T10:4862.2890-4.9273-224194.25196.38.4570?35.248035.250016033
74AB62A/47738-1 1991-09-23T02:3762.9705-4.9452-19624.754.88.6470?34.807034.808066069
74AB62A/47738-11991-09-23T02:3762.9705-4.9452-1962119.46120.77.1850?35.136035.019056037
74AB62A/47738-11991-09-23T02:3762.9705-4.9452-1962346.71350.51.2620#34.865034.913046047
74AB62A/47738-11991-09-23T02:3762.9705-4.9452-1962961.92973.8-0.5670?34.906034.905036036
74AB62A/47738-11991-09-23T02:3762.9705-4.9452-19621444.351463.8-0.8280?34.908034.908026083
74AB62A/47738-11991-09-23T02:3762.9705-4.9452-19621914.441942.3-0.8950?34.907034.907016064
74AB62A/47740-1 1991-09-23T06:2563.3070-4.9388-23237.337.49.1240?35.035035.036056084
74AB62A/47740-11991-09-23T06:2563.3070-4.9388-2323319.12322.63.1580?34.938034.931046048
74AB62A/47740-11991-09-23T06:2563.3070-4.9388-23231004.961017.5-0.5740?34.908034.908036039
74AB62A/47740-11991-09-23T06:2563.3070-4.9388-23231483.551503.7-0.7960?34.910034.909026038
74AB62A/47740-11991-09-23T06:2563.3070-4.9388-23231984.942014.2-0.8730?34.910034.909016057
74AB62A/47742-1 1991-09-23T10:2863.3088-4.1025-26345.645.79.1720?34.816034.835066046
74AB62A/47742-11991-09-23T10:2863.3088-4.1025-2634492.44498.0-0.0380?34.899034.899056045
74AB62A/47742-11991-09-23T10:2863.3088-4.1025-2634992.651005.0-0.6480?34.909034.907046044
74AB62A/47742-11991-09-23T10:2863.3088-4.1025-26341496.341516.7-0.8470?34.910034.909036043
74AB62A/47742-11991-09-23T10:2863.3088-4.1025-26341999.172028.7-0.8990?34.909034.908026042
74AB62A/47742-11991-09-23T10:2863.3088-4.1025-26342592.722634.6-0.8710?34.909034.909016041