Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

Sabatier, Pierre; Poulenard, Jérôme; Fanget, Bernard; Reyss, Jean-Louis; Develle, Anne-Lise; Wilhelm, Bruno; Ployon, Estelle; Pignol, Cécile; Naffrechoux, Emmanuel; Dorioz, Jean-Marcel; Montuelle, Bernard; Arnaud, Fabien (2014): Radionuclides of sediment core SAN11P1 [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.836158, In supplement to: Sabatier, P et al. (2014): Long-term relationships among pesticide applications, mobility, and soil erosion in a vineyard watershed. Proceedings of the National Academy of Sciences, 111(44), 15647-15652, https://doi.org/10.1073/pnas.1411512111

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Coverage:
Latitude: 45.494980 * Longitude: 5.985720
Date/Time Start: 2012-12-05T00:00:00 * Date/Time End: 2012-12-05T00:00:00
Minimum DEPTH, sediment/rock: 0.005 m * Maximum DEPTH, sediment/rock: 0.580 m
Event(s):
SAN11P1 * Latitude: 45.494980 * Longitude: 5.985720 * Date/Time: 2012-12-05T00:00:00 * Elevation Start: 292.0 m * Elevation End: -12.0 m * IGSN: EDYSAN004 * Recovery: 0.955 m * Location: Lac de Saint-André, France * Method/Device: Gravity corer, UWITEC (GCUWI)
Comment:
Activities of samples were analyzed using well-type, germanium detectors placed at the Laboratoire Souterrain de Modane (LSM), which is located under 1700 m of rock.
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
DEPTH, sediment/rockDepth sedmGeocode
Lead-210 activity per mass210PbBq/kgSabatier, PierreHigh-purity Germanium (HPGe) detector
Lead-210, standard deviation210Pb std dev±Sabatier, PierreHigh-purity Germanium (HPGe) detector
Radium-226 activity per mass226RaBq/kgSabatier, PierreHigh-purity Germanium (HPGe) detector
Radium-226, standard deviation226Ra std dev±Sabatier, PierreHigh-purity Germanium (HPGe) detector
Caesium-137, activity per mass137CsBq/kgSabatier, PierreHigh-purity Germanium (HPGe) detector
Caesium-137, standard deviation137Cs std dev±Sabatier, PierreHigh-purity Germanium (HPGe) detector
Americium-241 activity per mass241AmBq/kgSabatier, PierreHigh-purity Germanium (HPGe) detector
Americium-241, standard deviation241Am std dev±Sabatier, PierreHigh-purity Germanium (HPGe) detector
Size:
240 data points

Data

Download dataset as tab-delimited text — use the following character encoding:


Depth sed [m]

210Pb [Bq/kg]

210Pb std dev [±]

226Ra [Bq/kg]

226Ra std dev [±]

137Cs [Bq/kg]

137Cs std dev [±]

241Am [Bq/kg]

241Am std dev [±]
0.005124.03.08.30.36.00.30.000.10
0.010139.07.08.10.65.90.50.500.20
0.015116.34.37.60.45.50.40.400.20
0.030125.46.28.50.64.00.00.260.26
0.040142.06.69.00.46.80.40.000.10
0.060107.92.48.60.26.90.20.300.09
0.070106.34.810.10.48.50.40.000.10
0.080109.06.011.40.78.40.70.100.30
0.090104.04.710.50.49.60.50.300.16
0.10096.64.69.60.48.80.40.190.23
0.11585.06.010.30.69.80.60.000.10
0.13588.73.310.90.39.70.30.360.15
0.15490.73.012.00.39.60.30.000.10
0.17595.23.48.30.311.50.40.300.15
0.18596.03.37.90.313.70.40.000.10
0.19594.13.27.80.315.10.40.000.10
0.20586.63.68.30.320.50.40.110.11
0.21574.93.07.60.014.00.40.000.10
0.23569.03.38.73.017.50.50.540.17
0.26565.92.810.40.327.40.51.100.17
0.28548.62.911.00.438.00.71.470.20
0.29543.82.612.00.339.90.61.420.19
0.30533.81.511.30.219.10.30.360.11
0.31533.91.511.10.214.10.20.400.10
0.32532.32.311.70.310.70.30.360.15
0.37025.32.310.90.41.50.20.230.16
0.41021.81.111.10.20.40.00.200.09
0.46025.52.321.50.40.00.00.170.19
0.52031.82.317.70.40.00.00.300.20
0.58018.41.918.70.30.00.00.320.17