Stancin, Andrea M; Gleason, James D; Owen, Robert M; Rea, David K; Blum, Joel D (2008): (Table 3) Nd-Sr isotopic composition of terrigenous extratct of sediment core MV0502-15JC [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.832076, In supplement to: Stancin, AM et al. (2008): Piston core record of Late Paleogene (31 Ma) to recent seafloor hydrothermal activity in the Southwest Pacific Basin. Paleoceanography, 23(1), PA1212, https://doi.org/10.1029/2006PA001406
Always quote citation above when using data! You can download the citation in several formats below.
Published: 2008 (exact date unknown) • DOI registered: 2014-05-21
Related to:
Stancin, Andrea M; Gleason, James D; Owen, Robert M; Rea, David K; Blum, Joel D (2008): Correction to “Piston core record of Late Paleogene (31 Ma) to recent seafloor hydrothermal activity in the Southwest Pacific Basin”. Paleoceanography, 23(4), PA4203, https://doi.org/10.1029/2008PA001688
Coverage:
Latitude: -31.703230 * Longitude: -143.505520
Minimum DEPTH, sediment/rock: 0.01 m * Maximum DEPTH, sediment/rock: 8.23 m
Event(s):
MV0502-15JC (SP-A9) * Latitude: -31.703230 * Longitude: -143.505520 * Elevation: -5082.0 m * Recovery: 8.35 m * Location: Southwest Pacific Basin * Method/Device: Jumbo Piston Core (JPC)
Parameter(s):
| # | Name | Short Name | Unit | Principal Investigator | Method/Device | Comment |
|---|---|---|---|---|---|---|
| 1 | DEPTH, sediment/rock | Depth sed | m | Geocode | ||
| 2 | Depth, top/min | Depth top | m | Stancin, Andrea M | ||
| 3 | Depth, bottom/max | Depth bot | m | Stancin, Andrea M | ||
| 4 | Strontium-87/Strontium-86 ratio | 87Sr/86Sr | Stancin, Andrea M | Thermal Ionization Mass Spectrometry (TIMS) | normalized to 86Sr/88Sr = 0.1194 | |
| 5 | Strontium-87/Strontium-86 ratio, error | 87Sr/86Sr e | ± | Stancin, Andrea M | Thermal Ionization Mass Spectrometry (TIMS) | 2 SE, internal (measured) error |
| 6 | Neodymium-143/Neodymium-144 ratio | 143Nd/144Nd | Stancin, Andrea M | Thermal Ionization Mass Spectrometry (TIMS) | normalized to 146/Nd/144Nd = 0.7219 | |
| 7 | Neodymium-143/Neodymium-144 ratio, error | 143Nd/144Nd e | ± | Stancin, Andrea M | Thermal Ionization Mass Spectrometry (TIMS) | 2 SE, internal (measured) error |
| 8 | Neodymium-143/Neodymium-144 ratio | 143Nd/144Nd | Stancin, Andrea M | Thermal Ionization Mass Spectrometry (TIMS) | normalized to 146/Nd/144Nd = 0.7219 | |
| 9 | ε-Neodymium | ε-Nd | Stancin, Andrea M | epsilon-Nd = 104[(143Nd/144Ndsample)/(143Nd/144Ndchur) -1], where 143Nd/144Ndchur = 0.512638 |
License:
Creative Commons Attribution 3.0 Unported (CC-BY-3.0)
Size:
96 data points
