Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

Faul, Kristina L; Delaney, Margaret Lois (2010): (Table S2b) Concentrations and accumulation rates of CaCO3 and biogenic barium for ODP Hole 113-689B [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.831403, In supplement to: Faul, KL; Delaney, ML (2010): A comparison of early Paleogene export productivity and organic carbon burial flux for Maud Rise, Weddell Sea, and Kerguelen Plateau, south Indian Ocean. Paleoceanography, 25(3), PA3214, https://doi.org/10.1029/2009PA001916

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Project(s):
Coverage:
Latitude: -64.517000 * Longitude: 3.099900
Date/Time Start: 1987-01-16T08:00:00 * Date/Time End: 1987-01-18T06:45:00
Minimum DEPTH, sediment/rock: 0.34 m * Maximum DEPTH, sediment/rock: 246.66 m
Event(s):
113-689B * Latitude: -64.517000 * Longitude: 3.099900 * Date/Time Start: 1987-01-16T08:00:00 * Date/Time End: 1987-01-18T06:45:00 * Elevation: -2091.0 m * Penetration: 297.3 m * Recovery: 229.45 m * Location: South Atlantic Ocean * Campaign: Leg113 * Basis: Joides Resolution * Method/Device: Drilling/drill rig (DRILL) * Comment: 33 cores; 297.3 m cored; 0 m drilled; 77.2 % recovery
Comment:
DEPTH, sediment/rock [m] is given in mbsf.
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
Sample code/labelSample labelFaul, Kristina LDSDP/ODP/IODP sample designation
DEPTH, sediment/rockDepth sedmGeocode
Density, wet bulkWBDg/cm3Faul, Kristina L
PorosityPoros% volFaul, Kristina L
Density, dry bulkDBDg/cm3Faul, Kristina L
Sedimentation rateSRcm/kaFaul, Kristina L
AGEAgeka BPGeocode
Phosphorus, reactiveP reactµmol/gFaul, Kristina L
Phosphorus, reactive standard deviationP react std dev±Faul, Kristina L
10 Accumulation rate, phosphorusAcc rate Pµmol/cm2/kaFaul, Kristina Lreactive
11 Calcium carbonateCaCO3%Faul, Kristina L
12 Accumulation rate, calcium carbonateAcc rate CaCO3mmol/cm2/kaFaul, Kristina L
13 RatioRatioFaul, Kristina Lreactive P/CaCO3
14 Barium, biogenicBa bioµmol/gFaul, Kristina L
15 Accumulation rate, biogenic bariumAcc rate Ba bioµmol/cm2/kaFaul, Kristina L
16 RatioRatioFaul, Kristina Lbiogenic Ba/reactive P
17 Silicon dioxideSiO2%Faul, Kristina L
18 Silicon dioxide, standard deviationSiO2 std dev±Faul, Kristina L
19 Accumulation rate, silicaAcc rate SiO2µmol/cm2/kaFaul, Kristina L
Size:
910 data points

Data

Download dataset as tab-delimited text — use the following character encoding:


Sample label

Depth sed [m]

WBD [g/cm3]

Poros [% vol]

DBD [g/cm3]

SR [cm/ka]

Age [ka BP]

P react [µmol/g]

P react std dev [±]
10 
Acc rate P [µmol/cm2/ka]
(reactive)
11 
CaCO3 [%]
12 
Acc rate CaCO3 [mmol/cm2/ka]
13 
Ratio
(reactive P/CaCO3)
14 
Ba bio [µmol/g]
15 
Acc rate Ba bio [µmol/cm2/ka]
16 
Ratio
(biogenic Ba/reactive P)
17 
SiO2 [%]
18 
SiO2 std dev [±]
19 
Acc rate SiO2 [µmol/cm2/ka]
113-689B-1H-1,34-360.341.2487.710.341.660.376.600.2520.7112.4056.230.79
113-689B-2H-1,30-325.601.2991.830.351.920.210.0032.5416.9015.230.34
113-689B-3H-1,10-1214.901.2897.650.280.790.010.0033.8442.7044.920.03
113-689B-4H-1,10-1224.401.3587.410.452.390.0415.100.1626.9511.3031.350.98
113-689B-5H-1,130-13235.101.5867.860.882.180.0689.800.026.222.904.880.67
113-689B-6H-1,10-1243.401.3569.630.642.080.1050.800.0431.8215.3010.730.38
113-689B-7H-1,10-1253.001.5362.650.8920.930.3134.500.6140.311.905.770.28
113-689B-8H-1,13-1562.631.5763.130.9214.550.7175.400.1921.991.508.461.37
113-689B-9H-1,13-1572.231.7361.111.100.633252306.840.094.8085.005.900.089.346.521.402.180.111.52
113-689B-10H-1,13-1581.831.6963.931.030.592274309.220.195.6061.403.800.1515.869.701.703.650.142.24
113-689B-11H-1,13-1591.431.7162.691.070.4572864010.580.145.2070.103.400.1513.766.701.302.470.211.21
113-689B-12H-1,13-15101.161.7862.221.140.452296109.160.204.7086.004.400.1114.607.531.600.600.030.31
113-689B-13H-1,16-18110.761.7074.400.940.464317804.700.062.0067.602.900.0721.769.464.607.300.723.17
113-689B-14H-1,21-23120.411.8065.051.130.395337204.740.062.1083.603.700.0612.005.382.502.350.211.05
113-689B-15H-1,13-15130.031.8766.081.190.5703564011.910.258.1082.505.600.1412.368.401.003.310.092.25
113-689B-15H-3,62-64133.521.6964.971.020.5703625017.920.5810.5086.205.000.2115.068.790.802.910.051.70
113-689B-15H-5,62-64136.521.8659.521.250.992366909.380.3411.6090.1011.200.1010.5813.101.101.810.402.24
113-689B-16H-1,10-12139.501.8858.601.280.992369908.920.0711.3083.1010.500.117.068.960.803.590.284.55
113-689B-16H-3,63-65143.031.8667.061.170.992373506.370.347.4090.2010.500.079.1110.591.401.360.091.59
113-689B-16H-6,62-64147.521.7958.301.190.992378007.880.249.3094.6011.200.086.167.290.800.500.350.60
113-689B-17H-1,10-12149.201.7958.301.190.992379708.990.0210.6090.3010.700.106.657.860.700.410.030.48
113-689B-17H-3,65-67152.751.9758.421.370.9923833013.490.5318.3089.5012.200.158.3611.370.601.110.941.51
113-689B-17H-5,60-62155.701.9257.721.330.3503900020.710.169.6091.104.200.238.023.720.401.340.080.62
113-689B-18H-1,10-12158.901.8657.411.270.350399107.030.053.1092.204.100.088.213.651.200.510.010.23
113-689B-18H-2,86-88161.161.8657.411.270.3504056013.920.256.2092.304.100.158.793.910.600.740.120.33
113-689B-18H-3,90-92162.701.8657.411.270.6044144016.760.5712.9088.206.800.1913.0210.000.801.070.120.82
113-689B-18H-4,87-89164.171.8257.531.230.2354195044.402.0312.9082.802.400.5412.743.690.301.470.340.43
113-689B-18H-5,90-92165.701.8257.531.230.4444257052.143.5028.5082.304.500.638.324.540.201.600.390.87
113-689B-18H-6,11-13166.411.7657.161.170.4444273040.912.0121.3082.804.300.495.953.100.101.650.090.86
113-689B-19H-1,11-13168.611.8056.991.220.4444323013.920.087.5087.804.700.166.413.460.500.620.050.33
113-689B-19H-2,88-90170.881.8056.991.220.4444374021.030.9411.3082.404.400.266.423.460.300.980.190.53
113-689B-19H-3,91-93172.411.8557.381.260.4924405012.940.488.0088.605.500.156.444.000.500.830.060.52
113-689B-19H-4,89-91173.891.8557.381.260.4924435011.700.297.3090.805.600.136.093.780.500.660.030.41
113-689B-19H-5,91-93175.411.8354.311.270.4924466016.240.4710.2087.705.500.196.704.190.401.540.640.96
113-689B-19H-6,87-89176.871.8354.311.270.492449608.420.185.3099.406.200.085.303.320.600.890.550.56
113-689B-20H-1,10-12178.201.8951.061.370.492452306.580.114.4093.606.300.073.952.650.600.400.030.27
113-689B-20H-2,89-91180.491.8951.061.370.4924570010.600.287.1092.206.200.114.943.320.500.490.080.33
113-689B-20H-3,90-92182.001.8455.701.270.4924600011.650.107.3089.305.600.135.183.230.400.950.250.60
113-689B-20H-4,90-92183.501.8455.701.270.8904629014.420.3316.3088.109.900.164.635.230.301.570.151.77
113-689B-21H-1,10-12187.901.7857.291.190.8904704010.200.3110.8091.109.700.115.375.700.500.530.020.56
113-689B-21H-2,91-93190.211.8155.991.240.890470409.790.1310.8092.9010.200.114.434.870.500.630.110.69
113-689B-21H-3,88-90191.681.8155.991.240.890472105.940.036.5089.709.900.073.543.900.604.990.085.48
113-689B-22X-1,10-12197.602.1143.461.660.8904787028.280.2141.9088.5013.100.328.4012.440.300.670.040.99
113-689B-22X-2,91-93199.912.1143.461.660.9964811016.190.4026.8089.6014.900.187.6212.630.501.220.702.03
113-689B-22X-3,93-95201.432.1143.461.660.9964826036.040.7159.7082.5013.700.449.8516.330.302.140.203.55
113-689B-22X-4,80-82202.802.1143.461.660.9964840016.090.2926.7083.7013.900.196.5010.770.401.130.011.87
113-689B-22X-5,40-42203.902.1143.461.660.2805367010.240.344.8093.604.400.114.662.170.500.720.180.33
113-689B-23X-1,12-14207.321.7960.371.170.2805489027.510.219.0084.302.800.336.792.230.202.830.070.93
113-689B-23X-2,138-140210.081.8063.611.150.2805588021.140.266.8088.902.900.244.661.490.200.720.170.23
113-689B-23X-3,105-107211.251.9448.771.440.2805630017.230.356.9091.503.700.195.312.140.300.500.030.20
113-689B-23X-4,49-51212.192.0943.091.650.2805663012.700.275.9092.504.300.144.782.200.400.680.140.31
113-689B-24X-1,16-18217.062.0943.091.650.2805837013.040.296.0090.604.200.144.662.150.402.860.041.32
113-689B-24X-1,53-55217.432.0943.091.650.2805850013.440.116.2090.404.200.155.062.330.401.090.530.50
113-689B-25X-1,10-12226.702.2443.091.800.2806182045.880.4823.1084.404.200.545.482.760.102.840.101.43
113-689B-25X-1,67-69227.272.2443.091.800.2806202010.390.165.2093.004.700.114.972.500.500.610.080.31
113-689B-27X-1,66-68246.662.1843.091.741.3446763020.280.1147.4088.9020.800.239.0521.140.401.180.272.75