Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

Moore, Gregory; Kanagawa, Kyuichi; Strasser, Michael; Dugan, Brandon; Maeda, Lena; Toczko, Sean; Expedition 338 Scientists (2014): Thermal conductivity of IODP Hole 338-C0002L [dataset]. SIO7 Data Center, J-CORES Database; Ocean Drilling Program, Center for Deep Earth Exploration (JAMSTEC), PANGAEA, https://doi.org/10.1594/PANGAEA.829969

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Related to:
Moore, Gregory; Kanagawa, Kyuichi; Strasser, Michael; Dugan, Brandon; Maeda, Lena; Toczko, Sean; Expedition 338 Scientists (2013): NanTroSEIZE Stage 3: NanTroSEIZE plate boundary deep riser 2. Integrated Ocean Drilling Program Management International, Inc., for the Integrated Ocean Drilling Program, 17, 1-12, https://doi.org/10.5194/sd-17-1-2014
Coverage:
Latitude: 33.299950 * Longitude: 136.637000
Date/Time Start: 2012-12-22T00:00:00 * Date/Time End: 2012-12-24T00:00:00
Minimum DEPTH, sediment/rock: 277.300 m * Maximum DEPTH, sediment/rock: 501.215 m
Event(s):
338-C0002L * Latitude: 33.299950 * Longitude: 136.637000 * Date/Time Start: 2012-12-22T00:00:00 * Date/Time End: 2012-12-24T00:00:00 * Elevation: -1937.5 m * Penetration: 505 m * Recovery: 186.4 m * Location: Nankai Trough * Campaign: Exp338 (NanTroSEIZE Plate Boundary Deep Riser 2) * Basis: Chikyu * Method/Device: Drilling/drill rig (DRILL) * Comment: 24 cores; 228 m Interval cored; 81.8 % recovered
Comment:
Geocode = [m CSF-A]
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
Sample code/labelSample labelExpedition 338 ScientistsDSDP/ODP/IODP sample designation
DEPTH, sediment/rockDepth sedmGeocode
Depth, top/minDepth topmExpedition 338 Scientists[m CSF-B]
Conductivity, thermalkW/m/KExpedition 338 ScientistsThermal conductivity meter TK04 (TeKa)
CommentCommentExpedition 338 ScientistsThermal conductivity meter TK04 (TeKa)Comment on measurement
TCON Probe NumTCON ProbeExpedition 338 ScientistsThermal conductivity meter TK04 (TeKa)Probe
TCON Probe NumTCON ProbeExpedition 338 ScientistsThermal conductivity meter TK04 (TeKa)Probe serial number
NumberNoExpedition 338 ScientistsThermal conductivity meter TK04 (TeKa)Number of iterative measurements
Time StampTime StampExpedition 338 ScientistsRegistration
Size:
407 data points

Data

Download dataset as tab-delimited text — use the following character encoding:


Sample label
(DSDP/ODP/IODP sample designation)

Depth sed [m]

Depth top [m]
([m CSF-B])

k [W/m/K]
(Thermal conductivity meter TK...)

Comment
(Comment on measurement, Therm...)

TCON Probe
(Probe, Thermal conductivity m...)

TCON Probe
(Probe serial number, Thermal ...)

No
(Number of iterative measureme...)

Time Stamp
(Registration)
338-C0002L-1X-1,30.0277.300277.3001.296VLQ60V1100512013-01-11T00:13:23
338-C0002L-1X-6,47.0282.715282.7151.333VLQ60V1100512013-01-11T00:13:23
338-C0002L-2X-1,24.0286.740286.7401.201VLQ60V1100512013-01-11T00:13:23
338-C0002L-3X-1,49.0296.490296.4900.750VLQ60V1100512013-01-11T00:13:23
338-C0002L-3X-4,42.0299.110299.1101.057VLQ60V1103612013-01-11T00:13:23
338-C0002L-4X-1,34.0305.840305.8401.132VLQ60V1100512013-01-11T00:13:23
338-C0002L-4X-4,41.0308.710308.7101.059VLQ60V1103612013-01-11T00:13:23
338-C0002L-5X-1,42.0315.420315.4201.275VLQ60V1100512013-01-11T00:13:23
338-C0002L-5X-8,27.0322.115322.1151.152VLQ60V1100512013-01-11T00:13:23
338-C0002L-6X-1,6.0324.560324.5601.013VLQ60V1100512013-01-11T00:13:23
338-C0002L-7X-1,10.0334.100334.1001.289VLQ60V1100512013-01-11T00:13:23
338-C0002L-8X-2,6.0343.865343.8651.356VLQ60V1100512013-01-11T00:13:23
338-C0002L-8X-9,33.0351.950351.9501.109VLQ60V1100512013-01-11T00:13:23
338-C0002L-9X-2,52.0354.140354.1401.277VLQ60V1100512013-01-11T00:13:23
338-C0002L-9X-4,52.0355.725355.7251.357VLQ60V1103612013-01-11T00:13:23
338-C0002L-9X-8,31.0359.015359.0150.835VLQ60V1100512013-01-11T00:13:23
338-C0002L-10X-2,36.0363.995363.9951.236VLQ60V1103612013-01-11T00:13:23
338-C0002L-10X-5,54.0365.940365.9401.188VLQ60V1100512013-01-11T00:13:23
338-C0002L-10X-7,47.0367.910367.9101.330VLQ60V1103612013-01-11T00:13:23
338-C0002L-11X-2,43.0373.625373.6251.344VLQ60V1100512013-01-11T00:13:23
338-C0002L-11X-5,43.0376.005376.0050.738Power Control was out of range.VLQ60V1103612013-01-11T00:13:23
338-C0002L-12X-2,45.0383.180383.1801.273VLQ60V1100512013-01-11T00:13:23
338-C0002L-12X-5,28.0386.530386.5301.241VLQ60V1103612013-01-11T00:13:23
338-C0002L-12X-8,24.0388.605388.6051.292VLQ60V1103612013-01-11T00:13:23
338-C0002L-13X-2,34.0392.460392.4551.096VLQ60V1100512013-01-11T00:13:23
338-C0002L-13X-5,45.0396.585396.5651.119VLQ60V1100512013-01-11T00:13:23
338-C0002L-14X-2,49.0402.390402.3031.012VLQ60V1100512013-01-11T00:13:23
338-C0002L-14X-4,39.0403.845403.6911.140VLQ60V1103612013-01-11T00:13:23
338-C0002L-14X-6,36.0406.625406.3421.225VLQ60V1100512013-01-11T00:13:23
338-C0002L-14X-8,44.0409.520409.1031.181VLQ60V1100512013-01-11T00:13:23
338-C0002L-15X-2,33.0411.185411.1641.209VLQ60V1100512013-01-11T00:13:23
338-C0002L-15X-5,42.0412.995412.9411.244VLQ60V1103612013-01-11T00:13:23
338-C0002L-16X-2,5.0420.525420.4821.174VLQ60V1100512013-01-11T00:13:23
338-C0002L-16X-5,41.0424.190423.9941.142VLQ60V1100512013-01-11T00:13:23
338-C0002L-16X-7,91.0427.315426.9881.137VLQ60V1100512013-01-11T00:13:23
338-C0002L-17X-2,46.0430.610430.4861.247VLQ60V1100512013-01-11T00:13:23
338-C0002L-17X-6,52.0434.045433.6561.134VLQ60V1100512013-01-11T00:13:23
338-C0002L-17X-9,31.0437.315436.6731.199VLQ60V1103612013-01-11T00:13:23
338-C0002L-18X-2,49.0439.890439.8901.192VLQ60V1100512013-01-11T00:13:23
338-C0002L-18X-4,49.0441.190441.1901.256VLQ60V1103612013-01-11T00:13:23
338-C0002L-18X-6,43.0443.935443.9351.365VLQ60V1103612013-01-11T00:13:23
338-C0002L-18X-8,46.0446.785446.7851.279VLQ60V1103612013-01-11T00:13:23
338-C0002L-19X-2,39.0449.605449.6051.212VLQ60V1100512013-01-11T00:13:23
338-C0002L-19X-4,35.0451.250451.2501.171VLQ60V1100512013-01-11T00:13:23
338-C0002L-19X-6,48.0453.900453.9001.262VLQ60V1100512013-01-11T00:13:23
338-C0002L-20X-1,43.0457.930457.9141.249VLQ60V1103612013-01-11T00:13:23
338-C0002L-20X-3,25.0459.295459.2291.301VLQ60V1103612013-01-11T00:13:23
338-C0002L-20X-5,45.0462.315462.1371.247VLQ60V1100512013-01-11T00:13:23
338-C0002L-20X-7,31.0464.835464.5641.120VLQ60V1103612013-01-11T00:13:23
338-C0002L-21X-1,130.0468.300468.2911.229VLQ60V1100512013-01-11T00:13:23
338-C0002L-21X-2,10.0468.515468.5041.300VLQ60V1103612013-01-11T00:13:23
338-C0002L-21X-8,97.0476.095476.0291.207VLQ60V1100512013-01-11T00:13:23
338-C0002L-22X-2,37.0477.530477.5301.151VLQ60V1100512013-01-11T00:13:23
338-C0002L-22X-4,37.0478.360478.3601.217VLQ60V1100512013-01-11T00:13:23
338-C0002L-22X-6,7.0480.580480.5800.976VLQ60V1103612013-01-11T00:13:23
338-C0002L-22X-8,135.0482.580482.5801.307VLQ60V1103612013-01-11T00:13:23
338-C0002L-24X-4,69.0500.350500.3501.142VLQ60V1103612013-01-11T00:13:23
338-C0002L-24X-6,24.0501.215501.2151.400VLQ60V1103612013-01-11T00:13:23