Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

Koppers, Anthony AP; Yamazaki, Toshitsugu; Geldmacher, Jörg; Expedition 330 Scientists (2014): Thermal conductivity of IODP Hole 330-U1373A [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.826313

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Related to:
Koppers, Anthony AP; Yamazaki, Toshitsugu; Geldmacher, Jörg; Expedition 330 Scientists (2011): Proceedings of the Integrated Ocean Drilling Program. Washington, DC (Integrated Ocean Drilling Program Management International, Inc.), 330, https://doi.org/10.2204/iodp.proc.330.101.2012
Other version:
IODP/USIO (2012): LIMS Database. Ocean Drilling Programm, Texas A&M University, College station TX 77845-9547, USA, https://web.iodp.tamu.edu/LORE/
Coverage:
Latitude: -28.564845 * Longitude: -173.280832
Minimum DEPTH, sediment/rock: 2.18 m * Maximum DEPTH, sediment/rock: 64.16 m
Event(s):
330-U1373A * Latitude: -28.564845 * Longitude: -173.280832 * Elevation: -1447.0 m * Recovery: 47.22 m * Campaign: Exp330 (Louisville Seamount Trail) * Basis: Joides Resolution * Method/Device: Drilling/drill rig (DRILL)
Comment:
Geocode = Depth CSF-A (m)
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
Sample code/labelSample labelExpedition 330 ScientistsDSDP/ODP/IODP sample designation
DEPTH, sediment/rockDepth sedmGeocode
Depth, top/minDepth topmExpedition 330 ScientistsDepth CSF-B (m)
Conductivity, thermalkW/m/KExpedition 330 ScientistsThermal conductivity meter TK04 (TeKa)Mean
Conductivity, standard deviationCond std dev±Expedition 330 ScientistsThermal conductivity meter TK04 (TeKa)
Number of measurementsn#Expedition 330 ScientistsThermal conductivity meter TK04 (TeKa)
Conductivity, thermalkW/m/KExpedition 330 ScientistsThermal conductivity meter TK04 (TeKa)Observations
Time StampTime StampExpedition 330 Scientists
Size:
84 data points

Data

Download dataset as tab-delimited text — use the following character encoding:


Sample label
(DSDP/ODP/IODP sample designation)

Depth sed [m]

Depth top [m]
(Depth CSF-B (m))

k [W/m/K]
(Mean, Thermal conductivity me...)

Cond std dev [±]
(Thermal conductivity meter TK...)

n [#]
(Thermal conductivity meter TK...)

k [W/m/K]
(Observations, Thermal conduct...)

Time Stamp
330-U1373A-1R-2,1382.182.1802.2900.05332.2172011-01-03T05:58:26
330-U1373A-2R-2,10211.9511.6151.4070.01331.3892011-01-03T08:55:22
330-U1373A-3R-3,13417.2917.2901.5500.10431.4032011-01-03T01:06:39
330-U1373A-5R-2,8826.1726.1701.8030.00431.8022011-01-04T08:40:38
330-U1373A-6R-2,9130.0830.0801.3340.01831.3452011-01-04T06:08:56
330-U1373A-7R-4,12837.9437.0251.2110.01531.1972011-01-04T02:17:18
330-U1373A-8R-2,9339.7539.6191.4930.00831.4822011-01-05T05:34:19
330-U1373A-9R-1,9843.0843.0801.2010.02431.1882011-01-05T03:14:01
330-U1373A-10R-3,1449.3148.8991.1790.04031.2322011-01-05T08:46:40
330-U1373A-11R-3,10354.9954.9901.7810.01731.7722011-01-06T03:13:21
330-U1373A-12R-2,7158.0658.0601.4890.00731.4802011-01-06T05:18:48
330-U1373A-13R-3,5864.1663.8611.7460.01031.7432011-01-06T07:09:24