Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

d'Hondt, Steven L; Inagaki, Fumio; Alvarez Zarikian, Carlos A; Expedition 329 Scientists (2014): Carbonate analysis from IODP Hole 329-U1365A [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.825669

Always quote citation above when using data! You can download the citation in several formats below.

Published: 2014-01-10DOI registered: 2014-03-11

RIS CitationBibTeX Citation ShareShow MapGoogle Earth

Related to:
d'Hondt, Steven L; Inagaki, Fumio; Alvarez Zarikian, Carlos A; Expedition 329 Scientists (2011): Proceedings of the Integrated Ocean Drilling Program. Washington, DC (Integrated Ocean Drilling Program Management International, Inc.), 329, https://doi.org/10.2204/iodp.proc.329.101.2011
Other version:
IODP/USIO (2012): LIMS Database. Ocean Drilling Programm, Texas A&M University, College station TX 77845-9547, USA, https://web.iodp.tamu.edu/LORE/
Coverage:
Latitude: -23.850822 * Longitude: -165.644373
Minimum DEPTH, sediment/rock: 0.03 m * Maximum DEPTH, sediment/rock: 75.00 m
Event(s):
329-U1365A * Latitude: -23.850822 * Longitude: -165.644373 * Elevation: -5695.6 m * Recovery: 74.06 m * Campaign: Exp329 (South Pacific Gyre Microbiology) * Basis: Joides Resolution * Method/Device: Drilling/drill rig (DRILL)
Comment:
Geocode = Top depth CSF-A (m)
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
Sample code/labelSample labelExpedition 329 ScientistsDSDP/ODP/IODP sample designation
DEPTH, sediment/rockDepth sedmGeocode
Depth, bottom/maxDepth botmExpedition 329 ScientistsBottom depth CSF-A (m)
Depth, top/minDepth topmExpedition 329 ScientistsTop depth CSF-B (m)
Depth, bottom/maxDepth botmExpedition 329 ScientistsBottom depth CSF-B (m)
Calcium carbonateCaCO3%Expedition 329 ScientistsCalculated
Carbon, inorganic, totalTIC%Expedition 329 ScientistsCoulometry
Carbon, totalTC%Expedition 329 ScientistsElement analyser CHNS
CalciumCa%Expedition 329 ScientistsElement analyser CHNS
10 Carbon, organic, totalTOC%Expedition 329 ScientistsElement analyser CHNS
Size:
626 data points

Data

Download dataset as tab-delimited text — use the following character encoding:


Sample label
(DSDP/ODP/IODP sample designation)

Depth sed [m]

Depth bot [m]
(Bottom depth CSF-A (m))

Depth top [m]
(Top depth CSF-B (m))

Depth bot [m]
(Bottom depth CSF-B (m))

CaCO3 [%]
(Calculated)

TIC [%]
(Coulometry)

TC [%]
(Element analyser CHNS)

Ca [%]
(Element analyser CHNS)
10 
TOC [%]
(Element analyser CHNS)
329-U1365A-1H-1,3-40.030.040.030.040.110.01
329-U1365A-1H-1,3-40.030.040.030.04
329-U1365A-1H-1,3-40.030.040.030.040.320.05
329-U1365A-1H-1,12-130.120.130.120.130.110.01
329-U1365A-1H-1,12-130.120.130.120.13
329-U1365A-1H-1,12-130.120.130.120.130.270.05
329-U1365A-1H-1,27-280.270.280.270.280.090.01
329-U1365A-1H-1,27-280.270.280.270.28
329-U1365A-1H-1,27-280.270.280.270.280.210.05
329-U1365A-1H-1,42-430.420.430.420.430.140.02
329-U1365A-1H-1,42-430.420.430.420.43
329-U1365A-1H-1,42-430.420.430.420.430.200.05
329-U1365A-1H-1,64-650.640.650.640.650.110.01
329-U1365A-1H-1,64-650.640.650.640.65
329-U1365A-1H-1,64-650.640.650.640.650.160.05
329-U1365A-1H-1,90-910.900.910.900.910.080.01
329-U1365A-1H-1,90-910.900.910.900.91
329-U1365A-1H-1,90-910.900.910.900.910.170.04
329-U1365A-1H-1,110-1111.101.111.101.110.070.01
329-U1365A-1H-1,110-1111.101.111.101.11
329-U1365A-1H-1,110-1111.101.111.101.110.130.040.09
329-U1365A-1H-2,112-1132.622.632.622.630.080.01
329-U1365A-1H-2,112-1132.622.632.622.63
329-U1365A-1H-2,112-1132.622.632.622.63
329-U1365A-1H-2,112-1132.622.632.622.630.100.03
329-U1365A-1H-3,110-1114.104.114.104.110.090.01
329-U1365A-1H-3,110-1114.104.114.104.11
329-U1365A-1H-3,110-1114.104.114.104.110.090.030.08
329-U1365A-1H-4,110-1115.605.615.605.610.070.01
329-U1365A-1H-4,110-1115.605.615.605.61
329-U1365A-1H-4,110-1115.605.615.605.610.050.01
329-U1365A-2H-1,116-1177.367.377.367.370.160.02
329-U1365A-2H-1,116-1177.367.377.367.37
329-U1365A-2H-1,116-1177.367.377.367.370.070.020.03
329-U1365A-2H-2,116-1178.868.878.868.870.680.08
329-U1365A-2H-2,116-1178.868.878.868.87
329-U1365A-2H-2,116-1178.868.878.868.870.130.01
329-U1365A-2H-3,116-11710.3610.3710.3610.370.680.08
329-U1365A-2H-3,116-11710.3610.3710.3610.37
329-U1365A-2H-3,116-11710.3610.3710.3610.370.130.01
329-U1365A-2H-4,116-11711.8611.8711.8611.870.390.05
329-U1365A-2H-4,116-11711.8611.8711.8611.87
329-U1365A-2H-4,116-11711.8611.8711.8611.870.090.010.04
329-U1365A-3H-1,89-9016.5916.6016.5916.600.650.08
329-U1365A-3H-1,89-9016.5916.6016.5916.60
329-U1365A-3H-1,89-9016.5916.6016.5916.600.110.010.03
329-U1365A-3H-2,145-14618.2718.2818.2718.280.650.08
329-U1365A-3H-2,145-14618.2718.2818.2718.28
329-U1365A-3H-2,145-14618.2718.2818.2718.280.130.010.04
329-U1365A-3H-5,145-14622.7722.7822.7722.780.260.03
329-U1365A-3H-5,145-14622.7722.7822.7722.78
329-U1365A-3H-5,145-14622.7722.7822.7722.78
329-U1365A-3H-5,145-14622.7722.7822.7722.780.050.01
329-U1365A-3H-6,113-11423.9523.9623.9523.960.280.03
329-U1365A-3H-6,113-11423.9523.9623.9523.96
329-U1365A-3H-6,113-11423.9523.9623.9523.960.060.01
329-U1365A-4H-1,105-10725.7525.7725.6925.710.250.03
329-U1365A-4H-1,105-10725.7525.7725.6925.71
329-U1365A-4H-1,105-10725.7525.7725.6925.710.040.01
329-U1365A-4H-2,105-10727.2527.2727.1127.130.230.03
329-U1365A-4H-2,105-10727.2527.2727.1127.13
329-U1365A-4H-2,105-10727.2527.2727.1127.130.050.01
329-U1365A-4H-3,105-10728.7528.7728.5228.540.320.04
329-U1365A-4H-3,105-10728.7528.7728.5228.54
329-U1365A-4H-3,105-10728.7528.7728.5228.540.050.01
329-U1365A-4H-5,105-10731.7531.7731.3631.380.290.03
329-U1365A-4H-5,105-10731.7531.7731.3631.380.350.04
329-U1365A-4H-5,105-10731.7531.7731.3631.38
329-U1365A-4H-5,105-10731.7531.7731.3631.38
329-U1365A-4H-5,105-10731.7531.7731.3631.380.050.01
329-U1365A-4H-5,105-10731.7531.7731.3631.380.040.010.04
329-U1365A-4H-6,105-10733.2533.2732.7732.790.460.05
329-U1365A-4H-6,105-10733.2533.2732.7732.79
329-U1365A-4H-6,105-10733.2533.2732.7732.790.060.010.01
329-U1365A-5H-1,128-13035.4835.5035.4435.460.270.03
329-U1365A-5H-1,128-13035.4835.5035.4435.46
329-U1365A-5H-1,128-13035.4835.5035.4435.46
329-U1365A-5H-1,128-13035.4835.5035.4435.460.050.01
329-U1365A-5H-2,128-13036.9837.0036.8936.910.400.05
329-U1365A-5H-2,128-13036.9837.0036.8936.91
329-U1365A-5H-2,128-13036.9837.0036.8936.910.050.01
329-U1365A-5H-3,128-13038.4838.5038.3438.360.270.03
329-U1365A-5H-3,128-13038.4838.5038.3438.36
329-U1365A-5H-3,128-13038.4838.5038.3438.360.040.00
329-U1365A-5H-4,137-13940.0740.0939.8839.890.240.03
329-U1365A-5H-4,137-13940.0740.0939.8839.89
329-U1365A-5H-4,137-13940.0740.0939.8839.890.040.00
329-U1365A-5H-5,138-14041.5841.6041.3441.350.210.03
329-U1365A-5H-5,138-14041.5841.6041.3441.35
329-U1365A-5H-5,138-14041.5841.6041.3441.350.030.000.01
329-U1365A-5H-6,139-14143.0943.1142.8042.820.170.02
329-U1365A-5H-6,139-14143.0943.1142.8042.82
329-U1365A-5H-6,139-14143.0943.1142.8042.820.030.00
329-U1365A-14H-1,140-14154.2054.2154.2054.210.300.04
329-U1365A-14H-1,140-14154.2054.2154.2054.21
329-U1365A-14H-1,140-14154.2054.2154.2054.210.070.00
329-U1365A-23H-1,135-13664.6564.6664.6564.660.230.03
329-U1365A-23H-1,135-13664.6564.6664.6564.66
329-U1365A-23H-1,135-13664.6564.6664.6564.660.030.00
329-U1365A-23H-2,135-13766.1566.1766.1566.170.150.02
329-U1365A-23H-2,135-13766.1566.1766.1566.17
329-U1365A-23H-2,135-13766.1566.1766.1566.170.010.00
329-U1365A-24H-1,110-11168.3068.3168.2968.300.190.02
329-U1365A-24H-1,110-11168.3068.3168.2968.30
329-U1365A-24H-1,110-11168.3068.3168.2968.300.040.000.00
329-U1365A-24H-2,110-11169.8269.8369.8069.810.220.03
329-U1365A-24H-2,110-11169.8269.8369.8069.81
329-U1365A-24H-2,110-11169.8269.8369.8069.810.040.00
329-U1365A-24H-3,120-12171.4271.4371.3971.400.330.04
329-U1365A-24H-3,120-12171.4271.4371.3971.400.040.00
329-U1365A-25H-1,120-12273.6073.6273.5973.610.810.10
329-U1365A-25H-1,120-12273.6073.6273.5973.61
329-U1365A-25H-1,120-12273.6073.6273.5973.610.090.00
329-U1365A-25H-2,110-11275.0075.0274.9875.000.770.09
329-U1365A-25H-2,110-11275.0075.0274.9875.00
329-U1365A-25H-2,110-11275.0075.0274.9875.000.070.00