Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

Escutia Dotti, Carlota; Brinkhuis, Hendrik; Klaus, Adam; Expedition 318 Scientists (2013): P-Wave velocity (PWC) from IODP Hole 318-U1359A [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.824501

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Related to:
Escutia Dotti, Carlota; Brinkhuis, Henk; Klaus, Adam; Expedition 318 Scientists (2011): Proceedings of the Integrated Ocean Drilling Program. Washington, DC (Integrated Ocean Drilling Program Management International, Inc.), 318, https://doi.org/10.2204/iodp.proc.318.101.2011
Other version:
IODP/USIO (2012): LIMS Database. Ocean Drilling Programm, Texas A&M University, College station TX 77845-9547, USA, https://web.iodp.tamu.edu/LORE/
Coverage:
Latitude: -64.903962 * Longitude: 143.961375
Minimum DEPTH, sediment/rock: 1.46 m * Maximum DEPTH, sediment/rock: 132.06 m
Event(s):
318-U1359A * Latitude: -64.903962 * Longitude: 143.961375 * Elevation: -3020.9 m * Recovery: 154.08 m * Campaign: Exp318 (Wilkes Land) * Basis: Joides Resolution * Method/Device: Drilling/drill rig (DRILL) * Comment: 22 cores; 193.5 m cored; 80 % recovered; 0 m drilled; 193.5 m penetrated
Comment:
Geocode = Depth CSF-A (m)
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
Sample code/labelSample labelExpedition 318 ScientistsDSDP/ODP/IODP sample designation
DEPTH, sediment/rockDepth sedmGeocode
Depth, top/minDepth topmExpedition 318 ScientistsDepth CSF-B (m)
Velocity, compressional wave along X-axisVp Xm/sExpedition 318 ScientistsP-Wave Velocity, Caliper System (PWC)
CaliperCALImmExpedition 318 ScientistsP-Wave Velocity, Caliper System (PWC)
Sonic travel timeSonic travel timeµsExpedition 318 ScientistsP-Wave Velocity, Caliper System (PWC)
Time StampTime StampExpedition 318 Scientists
Size:
516 data points

Data

Download dataset as tab-delimited text — use the following character encoding:


Sample label

Depth sed [m]

Depth top [m]

Vp X [m/s]

CALI [mm]

Sonic travel time [µs]

Time Stamp
318-U1359A-2H-1,85.71.461.350161530.4718.892010-02-08T14:25:00
318-U1359A-2H-2,26.52.372.850156029.4918.912010-02-08T14:30:00
318-U1359A-2H-3,54.14.144.350156930.1019.202010-02-08T14:30:00
318-U1359A-2H-4,42.45.525.850155130.9319.962010-02-08T14:35:00
318-U1359A-2H-5,27.76.887.350157628.4318.052010-02-08T14:35:00
318-U1359A-2H-6,20.58.318.730156730.4419.442010-02-08T14:35:00
318-U1359A-3H-1,8510.9510.850162632.3619.922010-02-08T16:20:00
318-U1359A-3H-2,74.412.3412.350159030.9519.482010-02-08T16:20:00
318-U1359A-3H-3,66.113.7613.850160030.7819.252010-02-08T16:25:00
318-U1359A-3H-4,35.214.9515.350158130.5619.342010-02-08T16:25:00
318-U1359A-3H-5,5116.6116.850156633.6621.522010-02-08T16:30:00
318-U1359A-3H-6,41.818.0218.050156134.0221.812010-02-08T16:30:00
318-U1359A-3H-7,3818.8818.830163434.6221.212010-02-08T16:35:00
318-U1359A-4H-1,131.520.9220.350160532.9320.532010-02-08T17:55:00
318-U1359A-4H-2,41.221.5121.850152331.5120.712010-02-08T17:55:00
318-U1359A-4H-3,57.423.1723.350155631.9120.532010-02-08T18:00:00
318-U1359A-4H-4,37.424.4724.850163031.2619.202010-02-08T18:00:00
318-U1359A-4H-5,20.125.8026.350155633.2321.382010-02-08T18:05:00
318-U1359A-4H-6,3327.4327.645155931.9320.502010-02-08T18:05:00
318-U1359A-6H-1,104.939.6539.350158728.8118.182010-02-08T20:30:00
318-U1359A-6H-2,80.140.9040.850162331.9619.712010-02-08T20:30:00
318-U1359A-6H-3,43.242.0342.350158034.3321.752010-02-08T20:35:00
318-U1359A-6H-4,7443.8443.850161234.8021.602010-02-08T20:45:00
318-U1359A-6H-5,9445.5445.350153633.0821.552010-02-08T20:45:00
318-U1359A-6H-6,10247.1246.810154333.2421.552010-02-08T20:50:00
318-U1359A-7H-1,73.248.8348.850155231.1820.102010-02-08T23:01:00
318-U1359A-7H-2,48.150.0850.350155630.1019.372010-02-08T23:06:00
318-U1359A-7H-3,58.551.6951.850156329.6218.962010-02-08T23:06:00
318-U1359A-7H-4,88.753.4953.350154131.3720.372010-02-08T23:21:00
318-U1359A-7H-5,46.354.5654.555154530.3819.692010-02-08T23:26:00
318-U1359A-8H-3,53.261.1361.350154032.5821.182010-02-09T00:46:00
318-U1359A-8H-4,96.463.0662.850153731.5520.542010-02-09T00:51:00
318-U1359A-8H-5,35.663.9664.350153928.3018.412010-02-09T00:51:00
318-U1359A-8H-6,65.565.7665.775154131.9520.752010-02-09T00:56:00
318-U1359A-9H-1,68.967.7967.850166532.8119.722010-02-09T02:36:00
318-U1359A-9H-2,19.668.8069.350162831.8019.552010-02-09T02:36:00
318-U1359A-9H-2,76.669.3769.350156130.5819.612010-02-09T02:36:00
318-U1359A-9H-3,46.170.5670.850156431.9220.422010-02-09T02:41:00
318-U1359A-9H-3,134.171.4470.850155033.0621.342010-02-09T02:41:00
318-U1359A-9H-4,80.872.4172.350119832.5627.192010-02-09T02:41:00
318-U1359A-9H-4,101.972.6272.350156631.3620.042010-02-09T02:41:00
318-U1359A-9H-5,93.374.0373.850157830.9719.642010-02-09T02:46:00
318-U1359A-9H-6,56.175.1675.160155933.1221.262010-02-09T02:46:00
318-U1359A-10H-1,33.176.9377.315152129.8219.622010-02-09T04:46:00
318-U1359A-10H-1,95.577.5677.315155230.6419.752010-02-09T04:46:00
318-U1359A-10H-2,28.578.3978.745155230.0019.352010-02-09T04:46:00
318-U1359A-10H-2,76.978.8778.745153530.2819.752010-02-09T04:46:00
318-U1359A-10H-3,78.980.3980.175155530.6119.712010-02-09T04:51:00
318-U1359A-10H-4,42.181.5281.605156133.0821.212010-02-09T04:51:00
318-U1359A-10H-5,80.583.4183.035118833.3828.132010-02-09T04:51:00
318-U1359A-10H-5,129.583.9083.035154732.9021.282010-02-09T04:56:00
318-U1359A-10H-6,42.584.5384.465155732.6821.022010-02-09T04:56:00
318-U1359A-10H-6,63.884.7484.465158832.3620.402010-02-09T04:56:00
318-U1359A-10H-7,16.685.7785.490178330.7017.232010-02-09T05:01:00
318-U1359A-10H-7,42.586.0385.490157831.5119.992010-02-09T05:01:00
318-U1359A-11H-1,7086.8086.850157633.3621.192010-02-09T07:16:00
318-U1359A-11H-2,81.388.4188.350114233.4029.262010-02-09T07:16:00
318-U1359A-11H-3,59.489.6989.850157533.0821.022010-02-09T11:15:00
318-U1359A-11H-4,77.191.3791.350154132.2420.932010-02-09T11:15:00
318-U1359A-11H-5,68.192.7892.850155030.7719.872010-02-09T11:15:00
318-U1359A-11H-6,58.794.1994.265154031.9320.762010-02-09T11:15:00
318-U1359A-12H-1,71.796.3296.350154532.5721.092010-02-09T11:15:00
318-U1359A-12H-2,65.597.7697.850155732.3120.762010-02-09T11:15:00
318-U1359A-12H-2,107.798.1897.850166331.6919.072010-02-09T11:15:00
318-U1359A-13H-1,68.2105.78105.815157230.7719.592010-02-09T14:10:00
318-U1359A-13H-2,37.9106.98107.245156530.4119.452010-02-09T14:10:00
318-U1359A-13H-3,54.7108.65108.680158033.1621.012010-02-09T11:15:00
318-U1359A-13H-3,137.2109.47108.680158230.3919.232010-02-09T11:15:00
318-U1359A-13H-3,48.2108.58108.680156028.0718.012010-02-09T14:15:00
318-U1359A-13H-4,46.1110.06110.115155632.6220.982010-02-09T11:15:00
318-U1359A-13H-4,66110.26110.115155329.8619.242010-02-09T14:15:00
318-U1359A-13H-5,80.4111.90111.545130931.8224.332010-02-09T11:20:00
318-U1359A-13H-5,47.8111.58111.545155532.8121.112010-02-09T14:15:00
318-U1359A-13H-6,74.9113.35112.930162331.4919.432010-02-09T11:20:00
318-U1359A-13H-6,74.4113.34112.930154432.8621.302010-02-09T14:15:00
318-U1359A-13H-7,33.5114.34113.960162632.2619.862010-02-09T14:20:00
318-U1359A-14H-1,86.6115.47115.340158831.2619.702010-02-09T16:40:00
318-U1359A-14H-2,72116.82116.815154932.1120.752010-02-09T16:40:00
318-U1359A-14H-3,36.4117.96118.290160530.1418.792010-02-09T16:45:00
318-U1359A-14H-4,48.5119.59119.765160932.1419.992010-02-09T16:45:00
318-U1359A-14H-5,51.8121.12121.240128330.7023.942010-02-09T16:45:00
318-U1359A-15H-2,86.6126.47126.325156532.1920.582010-02-09T19:15:00
318-U1359A-15H-3,63.1127.73127.810159631.8119.942010-02-09T19:21:00
318-U1359A-15H-4,80.9129.41129.290154633.6521.792010-02-09T19:21:00
318-U1359A-15H-5,44.6130.55130.775159132.1020.202010-02-09T19:26:00
318-U1359A-15H-6,46.3132.06132.170158331.5319.932010-02-09T19:31:00