Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

Escutia Dotti, Carlota; Brinkhuis, Hendrik; Klaus, Adam; Expedition 318 Scientists (2013): Carbonate analysis from IODP Hole 318-U1359A [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.824492

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Related to:
Escutia Dotti, Carlota; Brinkhuis, Henk; Klaus, Adam; Expedition 318 Scientists (2011): Proceedings of the Integrated Ocean Drilling Program. Washington, DC (Integrated Ocean Drilling Program Management International, Inc.), 318, https://doi.org/10.2204/iodp.proc.318.101.2011
Other version:
IODP/USIO (2012): LIMS Database. Ocean Drilling Programm, Texas A&M University, College station TX 77845-9547, USA, https://web.iodp.tamu.edu/LORE/
Coverage:
Latitude: -64.903962 * Longitude: 143.961375
Minimum DEPTH, sediment/rock: 0.43 m * Maximum DEPTH, sediment/rock: 185.89 m
Event(s):
318-U1359A * Latitude: -64.903962 * Longitude: 143.961375 * Elevation: -3020.9 m * Recovery: 154.08 m * Campaign: Exp318 (Wilkes Land) * Basis: Joides Resolution * Method/Device: Drilling/drill rig (DRILL) * Comment: 22 cores; 193.5 m cored; 80 % recovered; 0 m drilled; 193.5 m penetrated
Comment:
Geocode = Top depth CSF-A (m)
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
Sample code/labelSample labelExpedition 318 ScientistsDSDP/ODP/IODP sample designation
DEPTH, sediment/rockDepth sedmGeocode
Depth, bottom/maxDepth botmExpedition 318 ScientistsBottom depth CSF-A (m)
Depth, top/minDepth topmExpedition 318 ScientistsTop depth CSF-B (m)
Depth, bottom/maxDepth botmExpedition 318 ScientistsBottom depth CSF-B (m)
Calcium carbonateCaCO3%Expedition 318 ScientistsCalculated
Carbon, inorganic, totalTIC%Expedition 318 ScientistsCoulometry
Carbon, totalTC%Expedition 318 ScientistsElement analyser CHNS
HydrogenH%Expedition 318 ScientistsElement analyser CHNS
10 CalciumCa%Expedition 318 ScientistsElement analyser CHNS
11 Sulfur, totalTS%Expedition 318 ScientistsElement analyser CHNS
12 Carbon, organic, totalTOC%Expedition 318 ScientistsCalculated
13 Sample commentSample commentExpedition 318 ScientistsOrganic carbon by CHNS sample treatment method
14 CommentCommentExpedition 318 Scientists
Size:
161 data points

Data

Download dataset as tab-delimited text — use the following character encoding:


Sample label
(DSDP/ODP/IODP sample designation)

Depth sed [m]

Depth bot [m]
(Bottom depth CSF-A (m))

Depth top [m]
(Top depth CSF-B (m))

Depth bot [m]
(Bottom depth CSF-B (m))

CaCO3 [%]
(Calculated)

TIC [%]
(Coulometry)

TC [%]
(Element analyser CHNS)

H [%]
(Element analyser CHNS)
10 
Ca [%]
(Element analyser CHNS)
11 
TS [%]
(Element analyser CHNS)
12 
TOC [%]
(Calculated)
13 
Sample comment
(Organic carbon by CHNS sample...)
14 
Comment
318-U1359A-1H-1,43-440.430.440.390.390.1700.0200.2000.020.020.18placeholder
318-U1359A-2H-2,20-212.302.312.302.310.1430.017placeholder
318-U1359A-2H-5,20-216.806.816.806.810.3470.042placeholder
318-U1359A-3H-3,91-9214.0114.0214.0114.020.8310.100placeholder
318-U1359A-4H-4,65-6624.7524.7624.7524.761.4510.1740.2500.010.000.08placeholder
318-U1359A-6H-4,105-10644.1444.1644.1444.160.1310.016placeholder
318-U1359A-7H-3,73-7451.8351.8451.8351.840.1610.019placeholder
318-U1359A-8H-5,41-4264.0164.0264.0164.020.4550.055placeholder
318-U1359A-9H-4,39-4071.9972.0071.9972.000.3250.039placeholderChanged values because of bad coulometer start. DJH
318-U1359A-10H-3,70-7180.3080.3180.1380.140.9530.1140.3500.030.010.24placeholder
318-U1359A-11H-4,50-5191.1091.1191.1091.110.4660.056placeholder
318-U1359A-12H-5,66-67102.26102.27102.26102.270.2720.033placeholder
318-U1359A-13H-6,105-106113.65113.66113.26113.270.2250.027placeholder
318-U1359A-14H-5,21-22120.81120.82120.71120.720.1710.021placeholder
318-U1359A-15H-4,91-92129.50129.52129.45129.450.1410.017placeholder
318-U1359A-17H-1,100-100144.10144.10144.07144.070.1410.0170.1200.020.000.10placeholder
318-U1359A-18X-1,98-99146.38146.39146.38146.391.0120.122placeholder
318-U1359A-19X-4,57-58160.07160.08160.07160.080.2060.025placeholder
318-U1359A-21X-2,54-55176.24176.25176.24176.250.0260.003placeholder
318-U1359A-22X-2,49-50185.89185.90185.89185.900.4540.054placeholder