Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

Verma, Surendra P (1982): (Table 3) Geochemical characteristics of samples of DSDP Leg 64 Holes igneous rocks [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.818521, In supplement to: Verma, SP (1982): Magnetic properties and incompatible element geochemistry of some igneous rocks from Deep Sea Drilling Project Leg 64. In: Curray, JR; Moore, DG; et al. (eds.), Initial Reports of the Deep Sea Drilling Project (U.S. Govt. Printing Office), 64, 667-671, https://doi.org/10.2973/dsdp.proc.64.115.1982

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Project(s):
Coverage:
Median Latitude: 26.084775 * Median Longitude: -110.848000 * South-bound Latitude: 22.959300 * West-bound Longitude: -111.507700 * North-bound Latitude: 27.253000 * East-bound Longitude: -108.978000
Date/Time Start: 1978-12-02T00:00:00 * Date/Time End: 1979-01-03T00:00:00
Minimum Elevation: -3022.0 m * Maximum Elevation: -1889.0 m
Event(s):
64-474A * Latitude: 22.959300 * Longitude: -108.978000 * Date/Time: 1978-12-02T00:00:00 * Elevation: -3022.0 m * Penetration: 626 m * Recovery: 290.1 m * Location: North Pacific/Gulf of California/BASIN * Campaign: Leg64 * Basis: Glomar Challenger * Method/Device: Drilling/drill rig (DRILL) * Comment: 49 cores; 453 m cored; 9.5 m drilled; 64 % recovery
64-477A * Latitude: 27.030000 * Longitude: -111.398800 * Date/Time: 1978-12-18T00:00:00 * Elevation: -2003.0 m * Penetration: 267 m * Recovery: 16 m * Location: North Pacific/Gulf of California/BASIN * Campaign: Leg64 * Basis: Glomar Challenger * Method/Device: Drilling/drill rig (DRILL) * Comment: 11 cores; 111 m cored; 9.5 m drilled; 14.4 % recovery
64-478 * Latitude: 27.096800 * Longitude: -111.507500 * Date/Time: 1978-12-24T00:00:00 * Elevation: -1889.0 m * Penetration: 464 m * Recovery: 297.6 m * Location: North Pacific/Gulf of California/CHANNEL * Campaign: Leg64 * Basis: Glomar Challenger * Method/Device: Drilling/drill rig (DRILL) * Comment: 49 cores; 427 m cored; 24 m drilled; 69.7 % recovery
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
1Event labelEvent
2Latitude of eventLatitude
3Longitude of eventLongitude
4Elevation of eventElevationm
5Sample code/labelSample labelVerma, Surendra PDSDP/ODP/IODP sample designation
6Rock typeRockVerma, Surendra P
7PotassiumKmg/kgVerma, Surendra P
8Potassium, standard deviationK std dev±Verma, Surendra P
9RubidiumRbmg/kgVerma, Surendra P
10Rubidium, standard deviationRb std dev±Verma, Surendra P
11CaesiumCsmg/kgVerma, Surendra P
12Caesium, standard deviationCs std dev±Verma, Surendra P
13BariumBamg/kgVerma, Surendra P
14Barium, standard deviationBa std dev±Verma, Surendra P
15StrontiumSrmg/kgVerma, Surendra P
16Strontium, standard deviationSr std dev±Verma, Surendra P
17Strontium-87/Strontium-86 ratio87Sr/86SrVerma, Surendra PNormalized to 86Sr/88Sr = 0.11940 and adjusted to SRM 987 87sr/86sr ratio of 0.71021. The measured ratio for the SRM 987 standard is 0.710282 ± 42 (2sigma, n = 19) during the period of about one year. In this period, the Eimer and Amend SrCO3 standard gave a value of 0.708071(1) ± 3(4) (2sigma, n = 9). The errors reported on individual 87Sr/86sr ratios are two times the standard error of the mean (2sigma-e) multiplied by 10**5.
18Strontium-87/Strontium-86 ratio, error87Sr/86Sr e±Verma, Surendra PErrors are the analytical errors multiplied by 10**5
19Rubidium/Strontium ratioRb/SrVerma, Surendra P
20Rubidium/Strontium ratio, standard deviationRb/Sr std dev±Verma, Surendra P
21Potassium/Strontium ratioK/SrVerma, Surendra P
22Standard deviationStd dev±Verma, Surendra PK/Sr ratio
23Potassium/Rubidium ratioK/RbVerma, Surendra P
24Standard deviationStd dev±Verma, Surendra PK/Rb ratio
25Potassium/Caesium ratioK/CsVerma, Surendra P
26Standard deviationStd dev±Verma, Surendra PK/Cs ratio
27Potassium/Barium ratioK/BaVerma, Surendra P
28Standard deviationStd dev±Verma, Surendra PK/Ba ratio
29RatioRatioVerma, Surendra PSr/Ba
30Standard deviationStd dev±Verma, Surendra PSr/Ba ratio
31RatioRatioVerma, Surendra PRb/Cs
32Standard deviationStd dev±Verma, Surendra PRb/Cs ratio
33Weight lossLoss%Verma, Surendra POn leaching
34StrontiumSrmg/kgVerma, Surendra PLeached
35Strontium, standard deviationSr std dev±Verma, Surendra PLeached
36Strontium-87/Strontium-86 ratio87Sr/86SrVerma, Surendra PLeached; Normalized to 86Sr/88Sr = 0.11940 and adjusted to SRM 987 87sr/86sr ratio of 0.71021. The measured ratio for the SRM 987 standard is 0.710282 ± 42 (2sigma, n = 19) during the period of about one year. In this period, the Eimer and Amend SrCO3 standard gave a value of 0.708071(1) ± 3(4) (2sigma, n = 9). The errors reported on individual 87Sr/86sr ratios are two times the standard error of the mean (2sigma-e) multiplied by 10**5.
37Strontium-87/Strontium-86 ratio, error87Sr/86Sr e±Verma, Surendra PLeached
38RatioRatioVerma, Surendra PSr concentration in leached sample/Sr concentration in whole rock ratio
Size:
159 data points

Download Data

Download dataset as tab-delimited text — use the following character encoding:

View dataset as HTML