Genty, Dominique; Combourieu-Nebout, Nathalie; Peyron, Odile; Blamart, Dominique; Wainer, Karine; Mansuri, Fatima; Ghaleb, Bassam; Isabello, Lauren; Dormoy, Isabelle; von Grafenstein, Ulrich; Bonelli, Stefano; Landais, Amaëlle; Brauer, Achim (2013): (Table 2c) Uranium series results of Villars Cave stalagmite Vil-stm27 [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.817542, In supplement to: Genty, D et al. (2010): Isotopic characterization of rapid climatic events during OIS3 and OIS4 in Villars Cave stalagmites (SW-France) and correlation with Atlantic and Mediterranean pollen records. Quaternary Science Reviews, 29(19-20), 2799-2820, https://doi.org/10.1016/j.quascirev.2010.06.035
Always quote citation above when using data! You can download the citation in several formats below.
Further details:
Genty, Dominique; Blamart, Dominique; Ouahdi, R; Gilmour, M; Baker, A; Jouzel, Jean; Van-Exter, Sandra (2003): (Table 1) Vil9 stalagmite TIMS uranium-series analyses [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.770431 (Uranium series results from stalagmite Vil-stm09)
Wainer, Karine; Genty, Dominique; Blamart, Dominique; Hoffmann, Dirk L; Couchoud, Isabelle (2009): (Table 2) Uranium series results of Villars Cave stalagmite Vil-stm14 [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.817609 (Uranium series results from stalagmite Vil-stm14)
Coverage:
Latitude: 45.440000 * Longitude: 0.780000
Minimum DISTANCE: 0.700 cm * Maximum DISTANCE: 81.600 cm
Event(s):
Parameter(s):
# | Name | Short Name | Unit | Principal Investigator | Method/Device | Comment |
---|---|---|---|---|---|---|
1 | Sample code/label | Sample label | Genty, Dominique | |||
2 | DISTANCE | Distance | cm | Geocode | ||
3 | Distance, standard error | Distance std e | ± | Genty, Dominique | ||
4 | Uranium-238 | 238U | mg/kg | Genty, Dominique | Thermal Ionization Mass Spectrometry (TIMS) | |
5 | Uranium-238, standard deviation | 238U std dev | ± | Genty, Dominique | Thermal Ionization Mass Spectrometry (TIMS) | |
6 | Uranium-234/Uranium-238 activity ratio | (234U/238U) | Genty, Dominique | Thermal Ionization Mass Spectrometry (TIMS) | ||
7 | Uranium-234/Uranium-238 activity ratio, standard deviation | (234U/238U) std dev | ± | Genty, Dominique | Thermal Ionization Mass Spectrometry (TIMS) | |
8 | Thorium-230/Thorium-232 activity ratio | (230Th/232Th) | Genty, Dominique | Thermal Ionization Mass Spectrometry (TIMS) | ||
9 | Thorium-230/Thorium-232 activity ratio, standard deviation | (230Th/232Th) std dev | ± | Genty, Dominique | Thermal Ionization Mass Spectrometry (TIMS) | |
10 | Thorium-230/Uranium-234 activity ratio | (230Th/234U) | Genty, Dominique | Thermal Ionization Mass Spectrometry (TIMS) | ||
11 | Thorium-230/Uranium-234 activity ratio, standard deviation | (230Th/234U) std dev | ± | Genty, Dominique | Thermal Ionization Mass Spectrometry (TIMS) | |
12 | Age, dated | Age dated | ka | Genty, Dominique | Age, Uranium-Thorium | uncorrected |
13 | Age, dated standard deviation | Age dated std dev | ± | Genty, Dominique | Age, Uranium-Thorium | uncorrected |
14 | Age, dated | Age dated | ka | Genty, Dominique | Age, Uranium-Thorium | corrected |
15 | Age, dated standard deviation | Age dated std dev | ± | Genty, Dominique | Age, Uranium-Thorium | corrected |
License:
Creative Commons Attribution 3.0 Unported (CC-BY-3.0)
Size: