Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

Bowen, Gabriel J; Maibauer, Bianca J; Kraus, Mary J; Röhl, Ursula; Westerhold, Thomas; Steimke, Amy; Gingerich, Philip D; Wing, Scott L; Clyde, William C (2014): Color data from BBCP Polecat Bench core 2A [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.817099, In supplement to: Bowen, GJ et al. (2014): Two massive, rapid releases of carbon during the onset of the Palaeocene–Eocene thermal maximum. Nature Geoscience, https://doi.org/10.1038/NGEO2316

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Coverage:
Latitude: 44.768850 * Longitude: -108.887960
Date/Time Start: 2011-07-19T07:45:00 * Date/Time End: 2011-07-20T04:40:00
Minimum DEPTH, sediment/rock: 3.403 m * Maximum DEPTH, sediment/rock: 129.772 m
Event(s):
PCB11-2A (7000-2A) * Latitude: 44.768850 * Longitude: -108.887960 * Date/Time Start: 2011-07-19T07:45:00 * Date/Time End: 2011-07-20T04:40:00 * Elevation: 0.0 m * IGSN: MBCR7000RHW0001 * Campaign: BBCP (7000) * Comment: Polecat Bench, ~10.5km W of Powell, Wyoming, USA, Drill rig: CS-1500, truck mounted. FD 129.83m, 130m drilled, Total Recovery 128.7 =99%
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
1Sample code/labelSample labelBBCR Science Team
2DEPTH, sediment/rockDepth sedmGeocode
3Depth, compositeDepth compmcdBBCR Science Team
4Section positionSectcmBBCR Science Team
5Color code HLS-systemColor HLSBBCR Science TeamSpectrophotometer Minolta CM-2600d
6Color, L*, lightnessL*BBCR Science TeamSpectrophotometer Minolta CM-2600d
7Color, a*a*BBCR Science TeamSpectrophotometer Minolta CM-2600d
8Color, b*b*BBCR Science TeamSpectrophotometer Minolta CM-2600d
9Color, XXBBCR Science TeamSpectrophotometer Minolta CM-2600d
10Color, YYBBCR Science TeamSpectrophotometer Minolta CM-2600d
11Color, ZZBBCR Science TeamSpectrophotometer Minolta CM-2600d
12Color REDredBBCR Science TeamSpectrophotometer Minolta CM-2600d595 - 700
13Color GREENgreenBBCR Science TeamSpectrophotometer Minolta CM-2600d515 - 595
14Color BLUEblueBBCR Science TeamSpectrophotometer Minolta CM-2600d400 - 515
15Color reflectance at 360 nmColor 360%BBCR Science TeamSpectrophotometer Minolta CM-2600d
16Color reflectance at 370 nmColor 370%BBCR Science TeamSpectrophotometer Minolta CM-2600d
17Color reflectance at 380 nmColor 380%BBCR Science TeamSpectrophotometer Minolta CM-2600d
18Color reflectance at 390 nmColor 390%BBCR Science TeamSpectrophotometer Minolta CM-2600d
19Color reflectance at 400 nmColor 400%BBCR Science TeamSpectrophotometer Minolta CM-2600d
20Color reflectance at 410 nmColor 410%BBCR Science TeamSpectrophotometer Minolta CM-2600d
21Color reflectance at 420 nmColor 420%BBCR Science TeamSpectrophotometer Minolta CM-2600d
22Color reflectance at 430 nmColor 430%BBCR Science TeamSpectrophotometer Minolta CM-2600d
23Color reflectance at 440 nmColor 440%BBCR Science TeamSpectrophotometer Minolta CM-2600d
24Color reflectance at 450 nmColor 450%BBCR Science TeamSpectrophotometer Minolta CM-2600d
25Color reflectance at 460 nmColor 460%BBCR Science TeamSpectrophotometer Minolta CM-2600d
26Color reflectance at 470 nmColor 470%BBCR Science TeamSpectrophotometer Minolta CM-2600d
27Color reflectance at 480 nmColor 480%BBCR Science TeamSpectrophotometer Minolta CM-2600d
28Color reflectance at 490 nmColor 490%BBCR Science TeamSpectrophotometer Minolta CM-2600d
29Color reflectance at 500 nmColor 500%BBCR Science TeamSpectrophotometer Minolta CM-2600d
30Color reflectance at 510 nmColor 510%BBCR Science TeamSpectrophotometer Minolta CM-2600d
31Color reflectance at 520 nmColor 520%BBCR Science TeamSpectrophotometer Minolta CM-2600d
32Color reflectance at 530 nmColor 530%BBCR Science TeamSpectrophotometer Minolta CM-2600d
33Color reflectance at 540 nmColor 540%BBCR Science TeamSpectrophotometer Minolta CM-2600d
34Color reflectance at 550 nmColor 550%BBCR Science TeamSpectrophotometer Minolta CM-2600d
35Color reflectance at 560 nmColor 560%BBCR Science TeamSpectrophotometer Minolta CM-2600d
36Color reflectance at 570 nmColor 570%BBCR Science TeamSpectrophotometer Minolta CM-2600d
37Color reflectance at 580 nmColor 580%BBCR Science TeamSpectrophotometer Minolta CM-2600d
38Color reflectance at 590 nmColor 590%BBCR Science TeamSpectrophotometer Minolta CM-2600d
39Color reflectance at 600 nmColor 600%BBCR Science TeamSpectrophotometer Minolta CM-2600d
40Color reflectance at 610 nmColor 610%BBCR Science TeamSpectrophotometer Minolta CM-2600d
41Color reflectance at 620 nmColor 620%BBCR Science TeamSpectrophotometer Minolta CM-2600d
42Color reflectance at 630 nmColor 630%BBCR Science TeamSpectrophotometer Minolta CM-2600d
43Color reflectance at 640 nmColor 640%BBCR Science TeamSpectrophotometer Minolta CM-2600d
44Color reflectance at 650 nmColor 650%BBCR Science TeamSpectrophotometer Minolta CM-2600d
45Color reflectance at 660 nmColor 660%BBCR Science TeamSpectrophotometer Minolta CM-2600d
46Color reflectance at 670 nmColor 670%BBCR Science TeamSpectrophotometer Minolta CM-2600d
47Color reflectance at 680 nmColor 680%BBCR Science TeamSpectrophotometer Minolta CM-2600d
48Color reflectance at 690 nmColor 690%BBCR Science TeamSpectrophotometer Minolta CM-2600d
49Color reflectance at 700 nmColor 700%BBCR Science TeamSpectrophotometer Minolta CM-2600d
50Color reflectance at 710 nmColor 710%BBCR Science TeamSpectrophotometer Minolta CM-2600d
51Color reflectance at 720 nmColor 720%BBCR Science TeamSpectrophotometer Minolta CM-2600d
52Color reflectance at 730 nmColor 730%BBCR Science TeamSpectrophotometer Minolta CM-2600d
53Color reflectance at 740 nmColor 740%BBCR Science TeamSpectrophotometer Minolta CM-2600d
Size:
124020 data points

Download Data

Download dataset as tab-delimited text — use the following character encoding:

View dataset as HTML (shows only first 2000 rows)