Hailwood, Ernie A; Rees, A I (1982): (Table 1) Magnetic properties of specimens from DSDP Hole 68-503A [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.817078
Always quote citation above when using data! You can download the citation in several formats below.
Abstract:
Measurements were made of the magnetic properties of 13 sediment samples from cores spanning the entire depth of Hole 503A. The principal aim was to make a preliminary assessment of the magnetic fabric of material obtained from hydraulic piston coring (HPC) which, though considerably bioturbated, might retain substantial traces of any depositional alignment of magnetic grains.
Earlier measurements on Deep Sea Drilling Project cores (Rees, 1971; Rees and Frederick, 1974; Hailwood and Sayre, 1979) suggested that the improved HPC sampling technique should, other things being equal, provide good magnetic fabric information. The Hole 503A sediments were known from shipboard measurements to possess comparatively strong stable remanence and therefore seemed likely subjects for this assessment.
Related to:
Hailwood, Ernie A; Rees, A I (1982): Magnetic properties of sediments from Hole 503A. In: Prell, WL; Gardner, JV; et al. (eds.), Initial Reports of the Deep Sea Drilling Project (U.S. Govt. Printing Office), 68, 441-442, https://doi.org/10.2973/dsdp.proc.68.118.1982
Project(s):
Deep Sea Drilling Project (DSDP)
Coverage:
Latitude: 4.067300 * Longitude: -95.636800
Date/Time Start: 1979-09-06T00:00:00 * Date/Time End: 1979-09-06T00:00:00
Minimum Elevation: -3672.0 m * Maximum Elevation: -3672.0 m
Event(s):
68-503A * Latitude: 4.067300 * Longitude: -95.636800 * Date/Time: 1979-09-06T00:00:00 * Elevation: -3672.0 m * Penetration: 235 m * Recovery: 138.2 m * Location: North Pacific/FLANK * Campaign: Leg68 * Basis: Glomar Challenger * Method/Device: Drilling/drill rig (DRILL) * Comment: 54 cores; 235 m cored; 0 m drilled; 58.8 % recovery
Comment:
All magnitudes are quoted in emu.
Parameter(s):
# | Name | Short Name | Unit | Principal Investigator | Method/Device | Comment |
---|---|---|---|---|---|---|
1 | Sample code/label | Sample label | Hailwood, Ernie A | DSDP/ODP/IODP sample designation | ||
2 | NRM, Intensity | Inten (NRM) | 10-6 emu | Hailwood, Ernie A | Magnetometer (MAG) | J0 |
3 | NRM, Intensity after demagnetization | Inten (AF) | 10-6 emu | Hailwood, Ernie A | Magnetometer (MAG) | J200 |
4 | Susceptibility | Suscept | sensor values | Hailwood, Ernie A | Magnetometer (MAG) | K x 10**-6 emu |
5 | Koenigsberger ratio | Q-ratio | Oe | Hailwood, Ernie A | Magnetometer (MAG) | Q0=J0/0.3K |
6 | Susceptibility | Suscept | sensor values | Hailwood, Ernie A | Magnetometer (MAG) | Anisotropy; h=(Kmax-Kmin)/K |
7 | Parameter | Parameter | arbitrary units | Hailwood, Ernie A | Magnetometer (MAG) | q=(Kmax-Kint)/((Kmax+Kint)/2-Kmin) |
License:
Creative Commons Attribution 3.0 Unported (CC-BY-3.0)
Size:
91 data points