Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

Marsh, Nicholas G; Tarney, J; Hendry, Graham L (1983): (Table 2) Geochemistry and element ratios for basalts from DSDP Hole 69-504B [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.816944, In supplement to: Marsh, NG et al. (1983): Trace element geochemistry of basalts from Hole 504B, Panama Basin, Deep Sea Drilling Project Legs 69 and 70. In: Cann, JR; Langseth, MG; Honnorez, J; Von Herzen, RP; White, SM; et al. (eds.), Initial Reports of the Deep Sea Drilling Project (U.S. Govt. Printing Office), 69, 747-763, https://doi.org/10.2973/dsdp.proc.69.149.1983

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Project(s):
Coverage:
Latitude: 1.227200 * Longitude: -83.730200
Date/Time Start: 1979-10-07T00:00:00 * Date/Time End: 1979-10-07T00:00:00
Minimum Elevation: -3460.0 m * Maximum Elevation: -3460.0 m
Event(s):
69-504B * Latitude: 1.227200 * Longitude: -83.730200 * Date/Time: 1979-10-07T00:00:00 * Elevation: -3460.0 m * Penetration: 489 m * Recovery: 262 m * Campaign: Leg69 * Basis: Glomar Challenger * Method/Device: Drilling/drill rig (DRILL)
Comment:
Empty cells mean no data.
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
Sample code/labelSample labelMarsh, Nicholas GDSDP/ODP/IODP sample designation
PiecePieceMarsh, Nicholas G
Silicon dioxideSiO2%Marsh, Nicholas GX-ray fluorescence (XRF)
Titanium dioxideTiO2%Marsh, Nicholas GX-ray fluorescence (XRF)
Aluminium oxideAl2O3%Marsh, Nicholas GX-ray fluorescence (XRF)
Iron oxide, Fe2O3Fe2O3%Marsh, Nicholas GX-ray fluorescence (XRF)Total iron
Manganese oxideMnO%Marsh, Nicholas GX-ray fluorescence (XRF)
Magnesium oxideMgO%Marsh, Nicholas GX-ray fluorescence (XRF)
Calcium oxideCaO%Marsh, Nicholas GX-ray fluorescence (XRF)
10 Sodium oxideNa2O%Marsh, Nicholas GX-ray fluorescence (XRF)
11 Potassium oxideK2O%Marsh, Nicholas GX-ray fluorescence (XRF)
12 Phosphorus pentoxideP2O5%Marsh, Nicholas GX-ray fluorescence (XRF)
13 TotalTotal%Marsh, Nicholas GX-ray fluorescence (XRF)
14 NickelNimg/kgMarsh, Nicholas GX-ray fluorescence (XRF)
15 ChromiumCrmg/kgMarsh, Nicholas GX-ray fluorescence (XRF)
16 ZincZnmg/kgMarsh, Nicholas GX-ray fluorescence (XRF)
17 GalliumGamg/kgMarsh, Nicholas GX-ray fluorescence (XRF)
18 RubidiumRbmg/kgMarsh, Nicholas GX-ray fluorescence (XRF)
19 StrontiumSrmg/kgMarsh, Nicholas GX-ray fluorescence (XRF)
20 YttriumYmg/kgMarsh, Nicholas GX-ray fluorescence (XRF)
21 ZirconiumZrmg/kgMarsh, Nicholas GX-ray fluorescence (XRF)
22 NiobiumNbmg/kgMarsh, Nicholas GX-ray fluorescence (XRF)
23 BariumBamg/kgMarsh, Nicholas GX-ray fluorescence (XRF)
24 LanthanumLamg/kgMarsh, Nicholas GX-ray fluorescence (XRF)
25 CeriumCemg/kgMarsh, Nicholas GX-ray fluorescence (XRF)
26 NeodymiumNdmg/kgMarsh, Nicholas GX-ray fluorescence (XRF)
27 LeadPbmg/kgMarsh, Nicholas GX-ray fluorescence (XRF)
28 ThoriumThmg/kgMarsh, Nicholas GX-ray fluorescence (XRF)
29 Iron/Magnesium ratioFe/MgMarsh, Nicholas GX-ray fluorescence (XRF)
30 Zirconium/Niobium ratioZr/NbMarsh, Nicholas GX-ray fluorescence (XRF)
31 Titanium/Zirconium ratioTi/ZrMarsh, Nicholas GX-ray fluorescence (XRF)
32 Cerium/Yttrium ratioCe/YMarsh, Nicholas GX-ray fluorescence (XRF)
33 Lithologic unit/sequenceUnitMarsh, Nicholas G
Size:
1068 data points

Data

Download dataset as tab-delimited text — use the following character encoding:


Sample label

Piece

SiO2 [%]

TiO2 [%]

Al2O3 [%]

Fe2O3 [%]

MnO [%]

MgO [%]

CaO [%]
10 
Na2O [%]
11 
K2O [%]
12 
P2O5 [%]
13 
Total [%]
14 
Ni [mg/kg]
15 
Cr [mg/kg]
16 
Zn [mg/kg]
17 
Ga [mg/kg]
18 
Rb [mg/kg]
19 
Sr [mg/kg]
20 
Y [mg/kg]
21 
Zr [mg/kg]
22 
Nb [mg/kg]
23 
Ba [mg/kg]
24 
La [mg/kg]
25 
Ce [mg/kg]
26 
Nd [mg/kg]
27 
Pb [mg/kg]
28 
Th [mg/kg]
29 
Fe/Mg
30 
Zr/Nb
31 
Ti/Zr
32 
Ce/Y
33 
Unit
69-504B-3-1,131-13425748.801.1514.612.20.188.811.842.2100.1110.08899.986619484154752853<1121572<11.611300.41
69-504B-4-2,114-11730749.600.8915.49.80.199.212.552.0500.0270.04599.7513640564142652244<16<1<14<1<11.231212
69-504B-5-2,68-7137950.100.8915.89.80.178.212.782.0800.1330.04099.9913842466154702546<17<1<14421.381162
69-504B-7-2,27-3045449.500.9215.89.90.178.512.712.2100.0800.04899.8412240373152642347<19124<121.341170.22
69-504B-7-4,84-8750249.400.9015.59.20.218.512.492.0800.0040.04598.3313938367142592246<15<114311.251170.12
69-504B-8-2,84-8753048.100.8815.88.50.158.612.132.1500.0050.06496.3812337861141612243<19<1551<11.141230.52
69-504B-9-1,48-5157249.500.8915.89.10.179.012.612.0000.0070.00499.1215139568142662145<16114<121.161190.12
69-504B-10-2,26-2962947.900.9814.19.60.158.312.212.0800.1360.04695.5010732568144742450<131362<11.341173
69-504B-11-2,134-13869349.000.9914.810.20.178.112.132.1300.3280.05497.908330966148752349<13<1552<11.471213
69-504B-12-2,65-6973650.601.0115.29.00.189.012.412.2300.1270.05199.8112232474154762450<115<156<111.161213
69-504B-13-2,109-11278249.701.0215.39.10.158.612.232.4200.1740.06398.789333771135772450<18<156<1<11.221223
69-504B-14-1,144-14885849.000.9414.710.70.188.112.302.0300.2330.04898.239729773145612443<181252<11.521313
69-504B-15-3,108-11297249.500.9715.19.80.178.412.312.0400.2530.05498.6010427972136622445<15<145221.361293
69-504B-16-3,45-5099250.301.0315.49.60.168.812.302.1700.1280.06299.9510027377144652545<1<1<166<1<11.261373
69-504B-16-4,14-19100449.100.9515.49.40.199.512.192.1000.1400.06599.0317542666133842353<12<1761<11.161074
69-504B-17-1,57-61103947.700.9214.29.20.159.111.981.7800.0740.05795.1617344767141872354<19166331.171024
69-504B-18-1,63-66108949.901.2815.69.60.178.911.832.3900.3990.148100.22103326641481562689105161610231.258.9861.45
69-504B-19-1,90-94112549.501.3215.09.30.219.012.542.1900.1340.14099.33122327661431762698136461812331.307.5811.65
69-504B-19-2,2-5113249.701.0015.78.80.159.212.042.1400.0940.05798.8815548170152942355<1121461<11.101090.46
69-504B-19-2,70-7114350.201.3614.99.70.198.612.472.2400.1580.17499.9912234375152170329011121.318.2907
69-504B-21-1,64-66118748.701.0414.710.50.158.512.112.1800.1100.08998.0896374651539624551<1<11.4355.01139
69-504B-21-2,27-30120350.041.0114.910.40.218.412.272.2600.1710.05599.7210829881145672853<18<156<111.431140.39
69-504B-21-2,33-35120349.101.0214.810.40.188.212.252.3350.1130.09598.4992376691539425561<1<11.4856.01099
69-504B-21-2,133-136121650.400.7516.98.90.168.513.271.9800.0680.037100.9612035865152571932<12<1561<11.221400.69
69-504B-21-5,56-59126549.200.8114.110.50.188.912.971.7800.0690.05698.5612335863132542334<14<11.3714315
69-504B-25-1,93-97141248.201.0013.510.60.208.012.401.9900.1000.04296.039628371123672550<1416211.5412017
69-504B-27-1,75-79146849.401.0214.910.50.167.812.122.2600.4410.05898.667727271139672549<15<1371<11.561250.317
69-504B-27-2,38-43148049.201.0715.610.10.168.611.842.4100.1910.08899.267937264155952559<1101262<11.361090.218
69-504B-28-1,23-26148949.901.0515.210.20.188.512.802.1270.0950.073100.121833746915210826591111.3959.010718
69-504B-28-2,22-25150549.800.9814.610.50.178.512.722.0800.1360.07299.5614525375153522540111.4340.014719
69-504B-28-2,23-27150549.000.9814.810.10.177.912.092.0600.2470.05597.4011822875146512342<15155121.471400.519
69-504B-28-3,16-18152249.400.9815.110.20.197.812.792.0100.1150.06998.6514326767152572644<12<11.5213419
69-504B-28-4,127-128153348.600.9814.710.30.187.312.532.0200.2620.07696.9510628170145602542<1<1<11.6414019
69-504B-29-1,88-91154248.901.0214.510.40.208.712.372.1700.1020.06698.439227170143682549<18147311.391250.420
69-504B-29-1,123-127157749.900.9715.710.50.198.112.862.0000.1470.079100.458526369155612645<1<121.5013020