Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

Thierens, Mieke; Pirlet, Hans; Colin, C; Latruwe, Kris; Vanhaecke, Frank; Lee, J R; Stuut, Jan-Berend W; Titschack, Jürgen; Huvenne, Veerle A I; Dorschel, Boris; Wheeler, Andrew J; Henriet, Jean-Pierre (2012): (Table 1) Nd-Sr isotope ratios of IODP Hole 307-U1317E sediments [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.816025, In supplement to: Thierens, M et al. (2012): Ice-rafting from the British–Irish ice sheet since the earliest Pleistocene (2.6 million years ago): implications for long-term mid-latitudinal ice-sheet growth in the North Atlantic region. Quaternary Science Reviews, 44, 229-240, https://doi.org/10.1016/j.quascirev.2010.12.020

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Coverage:
Latitude: 51.379983 * Longitude: -11.717633
Minimum DEPTH, sediment/rock: 0.23 m * Maximum DEPTH, sediment/rock: 154.93 m
Event(s):
307-U1317E * Latitude: 51.379983 * Longitude: -11.717633 * Elevation: -781.1 m * Recovery: 163.48 m * Campaign: Exp307 (Porcupine Basin Carbonate Mounds) * Basis: Joides Resolution * Method/Device: Drilling/drill rig (DRILL) * Comment: 18 cores; 158.6 m cored; 103.1 % recovered; 0 m drilled; 158.6 m penetrated
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
1NumberNoThierens, Mieke
2Sample code/labelSample labelThierens, MiekeDSDP/ODP/IODP sample designation
3DEPTH, sediment/rockDepth sedmGeocode – mbsf
4Sediment typeSedimentThierens, MiekeIRD = ice rafted debris, BS = background-sediment-layer
5Size fraction < 0.002 mm, clay<2 µm%Thierens, Miekevol.%
6Strontium-87/Strontium-86 ratio87Sr/86SrThierens, MiekeMulti-collector inductively coupled plasma mass spectrometer (MC-ICP-MS)
7Strontium-87/Strontium-86 ratio, error87Sr/86Sr e±Thierens, MiekeMulti-collector inductively coupled plasma mass spectrometer (MC-ICP-MS)2 sigma
8Neodymium-143/Neodymium-144 ratio143Nd/144NdThierens, MiekeMulti-collector inductively coupled plasma mass spectrometer (MC-ICP-MS)
9Neodymium-143/Neodymium-144 ratio, error143Nd/144Nd e±Thierens, MiekeMulti-collector inductively coupled plasma mass spectrometer (MC-ICP-MS)2 sigma
10ε-Neodymium (0)ε-Nd(0)Thierens, MiekeMulti-collector inductively coupled plasma mass spectrometer (MC-ICP-MS)
Size:
144 data points

Download Data

Download dataset as tab-delimited text — use the following character encoding:

View dataset as HTML