Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

Mussett, Alan E; Barker, Peter F (1983): (Table 1) Apparent ages from 40Ar/39Ar heating steps for DSDP Hole 72-516F basalts [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.811444, Supplement to: Mussett, AE; Barker, PF (1983): 40Ar/39Ar age spectra of basalts, Deep Sea Drilling Project Site 516. In: Barker, PF; Carlson, RL; Johnson, DA; et al. (eds.), Initial Reports of the Deep Sea Drilling Project (U.S. Govt. Printing Office), 72, 467-470, https://doi.org/10.2973/dsdp.proc.72.116.1983

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Abstract:
Submarine basalts are difficult to date accurately by the potassium-argon method. Dalrymple and Moore (1968) and Dymond (1970), for example, showed that, when the conventional K-Ar method is used, pillow lavas may contain excess 40Ar. Use of the 40Ar/39Ar step-heating method has not overcome the problem, as had been hoped, and has produced some conflicting results. Ozima and Saito (1973) concluded that the excess 40Ar is retained only in high temperature sites, but Seidemann (1978) found that it could be released at all temperatures. Furthermore, addition of potassium, from seawater, to the rock after it has solidified can result in low ages (Seidemann, 1977), the opposite effect to that of excess 40Ar. Thus, apparent ages may be either greater or less than the age of extrusion. Because of this discouraging record, the present study was approached pragmatically, to investigate whether self-consistent results can be obtained by the 40Ar/39Ar step-heating method.
Project(s):
Coverage:
Latitude: -30.276500 * Longitude: -35.285000
Date/Time Start: 1980-03-11T00:00:00 * Date/Time End: 1980-03-11T00:00:00
Minimum Elevation: -1313.0 m * Maximum Elevation: -1313.0 m
Event(s):
72-516F * Latitude: -30.276500 * Longitude: -35.285000 * Date/Time: 1980-03-11T00:00:00 * Elevation: -1313.0 m * Penetration: 1270.6 m * Recovery: 690.1 m * Location: South Atlantic/CONT RISE * Campaign: Leg72 * Basis: Glomar Challenger * Method/Device: Drilling/drill rig (DRILL) * Comment: 127 cores; 1092.5 m cored; 9 m drilled; 63.2 % recovery
Comment:
Blanks indicate not measured. 40Ar/30Ar, 39Ar/36Ar, and 37Ar/36Ar ratios corrected for mass discrimination and interfering isotopes.
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
Sample code/labelSample labelMussett, Alan EDSDP/ODP/IODP sample designation
PiecePieceMussett, Alan E
CommentCommentMussett, Alan EIrradiation number
Heating stepHeating stepMussett, Alan E
Temperature, technicalT tech°CMussett, Alan E#0 = fusion
ArgonAr%Mussett, Alan ERadiogenic; # = a zero measured 36Ar caused these results
Argon-3939Ar%Mussett, Alan EReleased; = percentage of total released over steps measured
CorrectioncorrMussett, Alan EInterfering isotopes
Argon-40/Argon-3640Ar/36ArMussett, Alan E# = a zero measured 36Ar caused these results
10 Argon-39/Argon-3639Ar/36ArMussett, Alan E# = a zero measured 36Ar caused these results
11 Argon-37/Argon-3637Ar/36ArMussett, Alan E# = a zero measured 36Ar caused these results
12 Age, datedAge datedkaMussett, Alan EApparent
13 Age, standard deviationAge std dev±Mussett, Alan EApparent
Size:
499 data points

Data

Download dataset as tab-delimited text — use the following character encoding:


Sample label

Piece

Comment

Heating step

T tech [°C]

Ar [%]

39Ar [%]

corr

40Ar/36Ar
10 
39Ar/36Ar
11 
37Ar/36Ar
12 
Age dated [ka]
13 
Age std dev [±]
72-516F-126-3,67-723bR1396150014.541.71.93460.2641.78031300030000
72-516F-126-3,67-723bR13962 to 6750
72-516F-126-3,67-723bR1396788076.420.43.4114917.800357.000872001800
72-516F-126-3,67-723bR1396890083.16.93.4152827.300556.000823001800
72-516F-126-3,67-723bR1396995086.912.73.6189033.500703.000866001800
72-516F-126-3,67-723bR139610 + 111030#102.61.64.0#0#0.000#0.0001073002400
72-516F-126-3,67-723bR139612120020.97.04.13711.48035.100926003900
72-516F-126-3,67-723bR139613#053.09.73.66096.590138.000866001900
72-516F-128-2,62-672dR1397140022.511.60.23820.6790.71821200017000
72-516F-128-2,62-672dR1397250051.116.00.66034.05013.6001310003500
72-516F-128-2,62-672dR1397382060.230.11.27347.68053.400998002700
72-516F-128-2,62-672dR1397487055.816.21.46626.27047.9001020004100
72-516F-128-2,62-672dR1397590045.95.41.75424.60044.900944004800
72-516F-128-2,62-672dR1397692051.95.91.86075.53056.100990004300
72-516F-128-2,62-672dR1397795050.34.51.95885.34057.100965002400
72-516F-128-2,62-672dR1397897553.73.32.36266.71090.200877005400
72-516F-128-2,62-672dR13979100051.96.83.05996.220109.000876002900
72-516F-126-2,3-91aR142724008.03.11.43220.4321.24029600032000
72-516F-126-2,3-91aR142734506.57.72.33161.0305.66010500021000
72-516F-126-2,3-91aR1427450013.810.73.53422.09017.4001180008000
72-516F-126-2,3-91aR1427555028.313.84.74084.62051.5001300003800
72-516F-126-2,3-91aR1427660051.318.37.35849.960169.0001570003000
72-516F-126-2,3-91aR1427765062.421.811.073911.100268.0002140003200
72-516F-126-2,3-91aR1427875051.08.17.057712.100201.0001270002300
72-516F-126-2,3-91aR1427985068.612.913.282617.800538.0001660002500
72-516F-126-2,3-91aR142710900-1.73.74.72910.4466.090-6100073000
72-516F-128-2,15-212aR142815004.82.40.43110.2440.20430300093000
72-516F-128-2,15-212aR142826009.612.40.53273.5704.210469006800
72-516F-128-2,15-212aR142837007.910.20.63213.7405.560361006900
72-516F-128-2,15-212aR1428475015.57.01.13494.55012.300635005300
72-516F-128-2,15-212aR1428585043.12.11.851411.70050.500999003300
72-516F-128-2,15-212aR1428694047.93.51.956013.00061.0001084002500
72-516F-128-2,15-212aR1428798048.53.92.856214.60098.900988002100
72-516F-128-2,15-212aR14288100051.45.83.059316.000115.0001008001900
72-516F-128-2,15-212aR14289102056.35.43.265320.200155.000962002100
72-516F-128-2,15-212aR142810104056.45.73.365320.600165.000945001600
72-516F-128-2,15-212aR142811115051.06.54.357718.600195.000842001700
72-516F-128-2,15-212aR142812120050.66.84.557118.300202.000838001900
72-516F-128-2,15-212aR142813#033.228.420.83959.200472.000779002900