Testarmata, Margaret M; Gose, Wulf A (1983): (Table 2) Relative intensity of axial component of magnetization subjected to the viscosity experiment at DSDP Hole 76-534A [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.809954, In supplement to: Testarmata, MM; Gose, WA (1983): The susceptibility and time-dependent magnetization of basalts from Deep Sea Drilling Project Hole 534A, Blake Plateau. In: Sheridan, RE; Gradstein, FM; et al. (eds.), Initial Reports of the Deep Sea Drilling Project (U.S. Govt. Printing Office), 76, 699-703, https://doi.org/10.2973/dsdp.proc.76.132.1983
Always quote citation above when using data! You can download the citation in several formats below.
Project(s):
Deep Sea Drilling Project (DSDP)
Coverage:
Latitude: 28.343300 * Longitude: -75.381700
Date/Time Start: 1980-10-21T00:00:00 * Date/Time End: 1980-10-21T00:00:00
Minimum Elevation: -4971.0 m * Maximum Elevation: -4971.0 m
Event(s):
76-534A * Latitude: 28.343300 * Longitude: -75.381700 * Date/Time: 1980-10-21T00:00:00 * Elevation: -4971.0 m * Penetration: 1666.5 m * Recovery: 612.4 m * Location: North Atlantic/BASIN * Campaign: Leg76 * Basis: Glomar Challenger * Method/Device: Drilling/drill rig (DRILL) * Comment: 127 cores; 1113.1 m cored; 31.5 m drilled; 55 % recovery
Comment:
For each sample, the top line lists the time between measurements and the NRM intensity of the axial component before the sample was placed in a 1-Oe field. The bottom line lists all measurements relative to this intensity. Decay = acquisition or decay of viscous components of magnetization between the two sets of measurements.
Parameter(s):
# | Name | Short Name | Unit | Principal Investigator | Method/Device | Comment |
---|---|---|---|---|---|---|
1 | Sample code/label | Sample label | Testarmata, Margaret M | DSDP/ODP/IODP sample designation | ||
2 | NRM, Intensity | Inten (NRM) | 10-6 emu | Testarmata, Margaret M | Magnetometer, long-core spinner, Digico | |
3 | - | - | Testarmata, Margaret M | D tau(0) | ||
4 | NRM, Intensity | Inten (NRM) | 10-6 emu | Testarmata, Margaret M | Magnetometer, cryogenic | Of axial component |
5 | Difference | Diff | Testarmata, Margaret M | T0, in month | ||
6 | Viscous remanent magnetization | VRM | mA/m | Testarmata, Margaret M | see reference(s) | |
7 | Difference | Diff | Testarmata, Margaret M | T2, in minute | ||
8 | - | - | Testarmata, Margaret M | Decay 1 | ||
9 | Difference | Diff | Testarmata, Margaret M | T3, in day | ||
10 | - | - | Testarmata, Margaret M | Decay 2 | ||
11 | Difference | Diff | Testarmata, Margaret M | T4, in day | ||
12 | - | - | Testarmata, Margaret M | Decay 3 |
License:
Creative Commons Attribution 3.0 Unported (CC-BY-3.0)
Size:
140 data points