Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

Chamley, Hervè; Debrabant, Pierre; Candillier, Anne-Marie; Foulon, J (1983): (Table 1) Geochemistry at DSDP Hole 76-534A [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.809831, Supplement to: Chamley, H et al. (1983): Clay mineralogical and inorganic geochemical stratigraphy of Blake-Bahama Basin since the Callovian, Site 534, Deep Sea Drilling Project Leg 76. In: Sheridan, RE; Gradstein, FM; et al. (eds.), Initial Reports of the Deep Sea Drilling Project, Washington (U.S. Govt. Printing Office), 76, 437-451, https://doi.org/10.2973/dsdp.proc.76.113.1983

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Abstract:
Mineralogical and geochemical investigations carried out on Callovian to upper Cenozoic basalt and sediments of Hole 534A are the bases for paleoenvironmental interpretations. The clay mineralogy primarily reflects events that occurred on the American continent (tectonics, morphology, alteration and pedogenesis, climate), except in the basalt and at the precise basalt/sediment contact where in situ alteration and local metamorphic effects exist. The inorganic and organic geochemistry mainly reflects the influence of and increasing distance from the spreading center during the first stages of sedimentation, the terrigenous influence from the Valanginian upward, and the bottom reducing or oxidizing conditions linked to the widening and deepening of the ocean affected by global tectonics.
Project(s):
Coverage:
Latitude: 28.343300 * Longitude: -75.381700
Date/Time Start: 1980-10-21T00:00:00 * Date/Time End: 1980-10-21T00:00:00
Minimum Elevation: -4971.0 m * Maximum Elevation: -4971.0 m
Event(s):
76-534A * Latitude: 28.343300 * Longitude: -75.381700 * Date/Time: 1980-10-21T00:00:00 * Elevation: -4971.0 m * Penetration: 1666.5 m * Recovery: 612.4 m * Location: North Atlantic/BASIN * Campaign: Leg76 * Basis: Glomar Challenger * Method/Device: Drilling/drill rig (DRILL) * Comment: 127 cores; 1113.1 m cored; 31.5 m drilled; 55 % recovery
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
Sample code/labelSample labelChamley, HervèDSDP/ODP/IODP sample designation
Lithology/composition/faciesLithologyChamley, Hervè
Silicon dioxideSiO2%Chamley, Hervèsee reference(s)
Aluminium oxideAl2O3%Chamley, Hervèsee reference(s)
Calcium oxideCaO%Chamley, HervèAtomic absorption spectrometry (AAS)
Magnesium oxideMgO%Chamley, HervèAtomic absorption spectrometry (AAS)
Sodium oxideNa2O%Chamley, HervèAtomic absorption spectrometry (AAS)
Potassium oxideK2O%Chamley, HervèAtomic absorption spectrometry (AAS)
Titanium dioxideTiO2%Chamley, HervèColorimetry
10 Phosphorus pentoxideP2O5%Chamley, HervèColorimetry
11 IronFe%Chamley, HervèAtomic absorption spectrometry (AAS)
12 ManganeseMnmg/kgChamley, HervèX-ray fluorescence (XRF)
13 ZincZnmg/kgChamley, HervèX-ray fluorescence (XRF)
14 LithiumLimg/kgChamley, HervèX-ray fluorescence (XRF)
15 NickelNimg/kgChamley, HervèX-ray fluorescence (XRF)
16 ChromiumCrmg/kgChamley, HervèX-ray fluorescence (XRF)
17 StrontiumSrmg/kgChamley, HervèX-ray fluorescence (XRF)
18 CobaltComg/kgChamley, HervèX-ray fluorescence (XRF)
19 CopperCumg/kgChamley, HervèX-ray fluorescence (XRF)
20 LeadPbmg/kgChamley, HervèX-ray fluorescence (XRF)
21 VanadiumVmg/kgChamley, HervèX-ray fluorescence (XRF)
22 Carbon, organic, totalTOCmg/kgChamley, HervèPyrolysis mass spectrometer
Size:
1893 data points

Data

Download dataset as tab-delimited text — use the following character encoding:


Sample label

Lithology

SiO2 [%]

Al2O3 [%]

CaO [%]

MgO [%]

Na2O [%]

K2O [%]

TiO2 [%]
10 
P2O5 [%]
11 
Fe [%]
12 
Mn [mg/kg]
13 
Zn [mg/kg]
14 
Li [mg/kg]
15 
Ni [mg/kg]
16 
Cr [mg/kg]
17 
Sr [mg/kg]
18 
Co [mg/kg]
19 
Cu [mg/kg]
20 
Pb [mg/kg]
21 
V [mg/kg]
22 
TOC [mg/kg]
76-534A-3-1,10011.601.3247.011.510.510.210.050.43221458112834146010173120
76-534A-4-2,10050.338.0314.943.541.331.110.320.463.18226110776198121533125901.25
76-534A-7-4,1006.670.7652.960.910.330.120.030.393582172328139412122910
76-534A-10-2,4847.339.6415.393.391.311.280.350.233.822951108456107109954127100
76-534A-12-1,10037.507.3726.932.131.050.930.250.202.54326844346801041123533701.48
76-534A-14-1,10450.339.6415.292.091.371.260.350.193.18216100585011284733827900.67
76-534A-18-1,5013.003.0245.581.010.480.580.120.141.0015104717412587816284040
76-534A-20-1,9982.606.210.650.881.201.690.170.192.6858068282769442332330
76-534A-24-1,10070.1714.080.381.291.142.610.685.7241084105561081321014211100.00
76-534A-24-1,13258.3321.260.351.511.212.610.819.617361211841041091632729311600.00
76-534A-25-1,10164.1716.250.521.461.862.500.748.1122175282609726318726110
76-534A-27-2,10060.6717.290.452.571.992.460.697.4022612145711163312250261200.45
76-534A-28-1,7762.5016.910.562.541.882.460.717.1529510545691111581962201300.83
76-534A-29-1,7259.3317.190.492.501.762.430.717.4026316353911073051971231601.61
76-534A-31-1,5261.6715.400.451.102.002.370.657.2218495331161055262358331300.77
76-534A-32-1,5064.5016.150.492.322.162.160.686.431952683249942891232281100.12
76-534A-34-1,5257.5017.850.982.331.662.510.767.72747726669614428426132372001.80
76-534A-36-2,2862.1717.670.632.131.762.660.758.0846311656541152841639291100.12
76-534A-37-1,11161.3317.290.452.651.872.940.747.8632676843541112841812825120
76-534A-39-2,6063.3316.530.592.741.862.440.737.1523790538581233261244271201.15
76-534A-41-1,10063.1714.360.842.621.742.660.639.762370137378011233725402490
76-534A-42-1,9966.3313.410.452.411.792.280.587.6824784327810432122502480
76-534A-44-2,5050.3315.876.582.631.622.820.707.408897636266155558234026160
76-534A-46-1,8732.006.2430.851.320.760.980.260.082.54242473343652615118730700.90
76-534A-47-1,10023.004.1636.481.000.570.770.170.061.931632002153606471111335703.68
76-534A-49-2,6823.335.0135.751.160.640.860.203.11210268217466700136132603.11
76-534A-50-4,696.671.7050.480.800.320.290.061.973685376352887815263320
76-534A-52-1,8650.0013.0410.812.531.372.260.545.4022660559591146472142331201.27
76-534A-54-1,4433.6710.3020.115.510.892.180.405.0033712205851901525183029900.77
76-534A-56-2,4026.677.5631.872.110.901.330.323.072746363442731136154827601.10
76-534A-59-1,5744.6713.4112.593.841.112.520.576.972372975568313315252630231000.63
76-534A-61-2,4046.5014.5510.673.521.272.610.677.68321127546911517003531311201.03
76-534A-63-1,9936.6711.0520.183.071.042.090.475.90305700445594900183131900.77
76-534A-65-2,4249.8314.749.063.231.342.380.646.58216104050741167732940271100.96
76-534A-67-1,13849.5013.239.483.011.252.240.575.6120583157691187842744251102.57
76-534A-68-2,7453.9014.955.323.551.402.490.635.9323114267861405733050201201.12
76-534A-70-3,3345.4012.0412.693.701.132.170.515.022371746071104942233416900.77
76-534A-71-4,5827.605.7227.804.200.591.040.233.8262212135536261624414417
76-534A-72-3,6035.609.4221.862.291.041.630.454.16247210456597710256923801.50
76-534A-73-5,7326.206.1530.191.560.611.080.262.8022088364182660185740442.05
76-534A-74-1,14048.1012.709.712.521.092.160.564.581893476185120631324925900.47
76-534A-75-6,7250.6013.7810.373.621.132.200.625.40237996155145556152728116
76-534A-76-3,4850.2012.3910.492.611.291.840.655.7424226851951415422837301100.56
76-534A-77-3,742.8012.3614.693.041.151.860.594.971581105269143673163520100
76-534A-78-2,9255.9016.015.533.441.452.270.736.101761107291167594343415105
76-534A-79-2,5323.305.8534.241.620.550.810.243.1222111625545962620452250
76-534A-80-4,2046.9012.1114.692.751.031.720.534.83182886465137512234029105
76-534A-81-3,5113.402.7941.670.800.280.440.041.311959512284051512292530
76-534A-82-1,11121.403.9338.331.000.320.780.101.65363110203049431194926400.99
76-534A-83-5,10728.807.2730.641.610.611.220.293.776777725337049515454317
76-534A-84-2,10923.806.2634.421.350.471.020.212.4042674243865589194620600.77
76-534A-85-1,11035.208.3725.951.710.661.130.372.964407235549749032634066
76-534A-86-2,9813.302.3044.940.740.180.360.050.985681008223535814182510
76-534A-88-3,9526.004.7834.471.210.330.880.181.73368110171294536877271930
76-534A-90-2,815.602.2843.630.850.190.450.060.914942058192633112352720
76-534A-91-1,10136.507.8426.062.010.451.710.333.772794725455737321324630
76-534A-92-2,13222.704.0337.631.120.270.750.131.56473841429343371272230
76-534A-93-3,1230.006.9028.331.720.541.439.5861510019656841624223140
76-534A-94-2,10641.7510.3918.982.590.871.870.486.846428426949151032213095
76-534A-95-3,5643.9011.1216.732.450.921.920.475.14279147312021071389107342770
76-534A-96-3,452.5012.199.333.101.162.060.607.642688430114112626381126110
76-534A-97-1,3032.805.9029.221.890.481.060.182.96171521619605563621562540
76-534A-99-1,5941.709.9016.692.640.791.700.344.68132657924748365823652280
76-534A-100-1,4245.0012.0913.813.310.982.190.558.2542189289998778291028121
76-534A-101-1,4942.0011.9415.872.830.942.040.488.1010057263010394636302721700.00
76-534A-102-3,4547.0010.4915.062.430.862.160.456.39111579298964521262127110
76-534A-103-1,10123.706.2033.542.160.441.130.223.16400014317494083216632650
76-534A-104-1,4660.0010.968.282.820.811.840.505.5720568441087750028352795
76-534A-105-1,12251.7013.939.782.960.852.690.576.1638430755412392352436434100
76-534A-107-1,6834.504.0930.861.300.270.830.161.7952610521324527412182640
76-534A-108-1,2544.2011.2317.652.530.742.320.497.23500131531895430020121790
76-534A-110-CC,1916.703.3343.400.940.190.580.101.661357796282623113256930
76-534A-112-1,4744.0011.0516.872.370.682.380.607.6161079178360384363322132
76-534A-113.1,2039.8011.3120.112.120.601.950.476.251080226204042337128926120
76-534A-114-1,9055.3314.175.072.741.052.370.8810.373262002062110395196419120
76-534A-115-1,2656.4013.765.442.591.032.270.949.62410115018226973427374281200.00
76-534A-117-1,1540.0010.4619.922.130.681.670.695.631120741772633374610621120
76-534A-119-1,11340.109.6419.922.270.681.360.725.451560121185842442297223120
76-534A-120-1,5135.001.5224.540.690.100.240.041.57330079131918372007281910
76-534A-122-1,14737.606.0422.801.430.361.160.272.9023006819584736830592760
76-534A-123-2,054.839.739.862.360.671.930.437.587636003798852003912631130
76-534A-123-2,10860.3010.825.312.060.712.190.507.015107153473861843028021130
76-534A-124-1,1249.109.1315.691.830.571.920.365.2714601163356612262016420110
76-534A-125-2,1947.607.3617.011.640.471.740.335.64201551528734923130183261201.35
76-534A-125-4,4853.339.739.832.740.632.030.478.97112030038728322138157281501.35
76-534A-126-3,4953.1010.529.182.360.662.350.497.921295174366310820527153261702.44
76-534A-127-1,5154.5010.469.022.180.642.320.436.681775110308869200227842150
76-534A-127-4,053.3310.969.763.190.732.450.498.941725129452848622631494380
76-534A-127-4,0Basalt40.3317.002.7311.381.730.461.0818.1616579847613818118913413922370
76-534A-127-4,1056.4010.507.573.130.662.310.488.76153577333677220023552370
76-534A-127-CC,152.908.2613.452.600.461.910.290.756.5934253165013918218911014010370
76-534A-127-CC,10Basalt39.0016.755.9711.081.710.180.9815.79194016329625618432732460
76-534A-129-1,118Basalt47.0016.839.028.532.000.220.989.58127514712991682318013720380
76-534A-129-1,140Sediments in basalt43.302.0827.482.790.140.272.6520604225222311696300
76-534A-129-1,140Sediments in basalt31.000.8332.381.420.100.195.54635037114014105172514190
76-534A-129-1,140Basalt47.2016.776.669.152.100.890.9611.417151051972168263317616350
76-534A-129-2,77Basalt47.7016.769.868.402.000.261.0210.49126011010971772376813623380