Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

Li, William K W (2013): Bacteria abundance measured on water bottle samples during HUDSON cruise HUD96/26 [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.808269

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Related to:
Spear, Donald (2000): JGOFS Canada Data Sets 1989-1998. CD-ROM Version 1.0 Dec. 2000, Marine Environmental Data Service, Department of Fisheries and Oceans, Canada
Project(s):
Coverage:
Median Latitude: 57.776923 * Median Longitude: -51.309231 * South-bound Latitude: 54.960000 * West-bound Longitude: -54.290000 * North-bound Latitude: 60.560000 * East-bound Longitude: -48.230000
Date/Time Start: 1996-10-20T00:00:00 * Date/Time End: 1996-10-28T00:00:00
Minimum DEPTH, water: 0.0 m * Maximum DEPTH, water: 3562.0 m
Event(s):
HUD96/26_BO8 * Latitude: 54.960000 * Longitude: -54.290000 * Date/Time: 1996-10-20T00:00:00 * Campaign: HUD96/26 * Basis: Hudson * Method/Device: Bottle, Niskin (NIS)
HUD96/26_BO15 * Latitude: 55.420000 * Longitude: -53.830000 * Date/Time: 1996-10-21T00:00:00 * Campaign: HUD96/26 * Basis: Hudson * Method/Device: Bottle, Niskin (NIS)
HUD96/26_BO19 * Latitude: 55.850000 * Longitude: -53.390000 * Date/Time: 1996-10-23T00:00:00 * Campaign: HUD96/26 * Basis: Hudson * Method/Device: Bottle, Niskin (NIS)
Comment:
Samples for enumeration of bacterial abundance were drawn from Niskin bottles and immediately preserved in 20 mL glass scintillation vials with 0.2 µm filtered (Millex-GS, Millipore Corp.) formalin (2% final concentration). Preserved samples were stored dark in a refrigerator. Each sample was poured over triplicate polycarbonate membranes (0.2 µm black Nuclepore) underlain by pre-wetted backing filters (Sartorius #11306) which aid in distributing cells in an even manner on the Nuclepore surface. Cells were stained for 10 minutes with DAPI at a final concentration of 2 µg/ml and then drawn through the filters at a vacuum pressure of about 150 mm Hg. The filters were examined by epifluorescence microscopy (Leitz Orthoplan) under ultraviolet excitation from a mercury arc lamp (HBO 100W).
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
1Event labelEvent
2Date/Time of eventDate/Time
3Latitude of eventLatitude
4Longitude of eventLongitude
5DEPTH, waterDepth watermGeocode
6BacteriaBact#/mlLi, BillCounting
Size:
152 data points

Download Data

Download dataset as tab-delimited text — use the following character encoding:

View dataset as HTML