Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

Erickson, A J; Simmons, G; Ryan, William B F (1977): Component parts of the World Heat Flow Data Collection [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.806987

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX Citation

Related to:
Erickson, A J; Simmons, G; Ryan, William B F (1977): Review of heat flow data from the Mediterranean and Aegean Seas. In: Biju-Duval, B and Montadert, L (eds.), International Symposium on Structural History of the Mediterranean Basins, Editions Technip, 263-280
International Heat Flow Commission, I H F C (2012): Global Heat Flow Database. The Global Heat Flow Database of the International Heat Flow Commission (IHFC), University of North Dakota, USA; (data copied, 2012-10), https://ihfc-iugg.org/products/global-heat-flow-database/data
Further details:
Jessop, Alan M; Hobart, Michael A; Sclater, John G (1976): The World Heat Flow Data Collection - 1975. Geological Survey of Canada, Earth Physics Branch, Geothermal Series, 5, 10 pp, hdl:10013/epic.40176.d002
Coverage:
Median Latitude: 36.591663 * Median Longitude: 19.838893 * South-bound Latitude: 32.966700 * West-bound Longitude: -4.033300 * North-bound Latitude: 41.983300 * East-bound Longitude: 35.433300
Minimum ELEVATION: -3955 m a.s.l. * Maximum ELEVATION: -956 m a.s.l.
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
Area/localityAreaErickson, A J
Sample, optional label/labor noLab noErickson, A J
LATITUDELatitudeGeocode
LONGITUDELongitudeGeocode
ELEVATIONElevationm a.s.l.Geocode
Depth, top/minDepth topmErickson, A J
Depth, bottom/maxDepth botmErickson, A JMaximum depth
Number of temperature dataNo TempsErickson, A J
Temperature gradientT gradmK/mErickson, A J
10 Number of conductivity measurementsNo CondErickson, A J
11 Conductivity, averageCond averageW/m KErickson, A J
12 Heat flowHFmW/m2Erickson, A J
13 NumberNoErickson, A JNumber of individual sites
14 Method commentMethod commErickson, A J
Size:
538 data points

Data

Download dataset as tab-delimited text — use the following character encoding:


Area

Lab no

Latitude

Longitude

Elevation [m a.s.l.]

Depth top [m]

Depth bot [m]

No Temps

T grad [mK/m]
10 
No Cond
11 
Cond average [W/m K]
12 
HF [mW/m2]
13 
No
14 
Method comm
XM 22CH61-1935.783313.1500-1525012555240.92501Ewing probe
XM 23CH61-2934.000019.6500-3955012527180.96261Ewing probe
XM 24CH61-3735.733325.2833-18620525290.84441Ewing probe
XM 25CH61-3934.366722.5333-26790422751.16321Ewing probe
XM 26CH61-4033.283323.1667-247006357111.00571Ewing probe
XM 27CH61-4234.250025.0167-350006325311.03261Ewing probe
XM 28CH61-4634.283326.2167-314005223311.08251Ewing probe
XM 29CH61-5035.516728.2000-245005229361.05301Ewing probe
XM 30CH61-5334.200028.9667-260308530490.88271Ewing probe
XM 31CH61-5435.333330.1167-201703238101.00381Ewing probe
XM 32CH61-5534.816731.0667-246607427220.93251Ewing probe
XM 33CH61-5633.000031.1000-2167010523340.89211Ewing probe
XM 34CH61-5733.183332.4833-192608416240.99161Ewing probe
XM 35CH61-5933.866733.2833-230107438260.92351Ewing probe
XM 36CH61-6236.016731.7667-250004328131.13321Ewing probe
XM 37CH61-6335.683332.9667-124007423241.10261Ewing probe
XM 38CH61-6435.933334.2333-95607522211.05231Ewing probe
XM 39CH61-6535.533335.4333-139207422120.93201Ewing probe
XM 40CH61-6634.316734.7000-198108437120.97361Ewing probe
XM 41CH61-6734.183333.6167-196607412130.93111Ewing probe
XM 42CH61-6834.883334.8833-159108531170.89281Ewing probe
XM 43CT- 1738.966714.1833-350475151190.921391Ewing probe
XM 44CT- 2939.333313.7333-349765175210.861511Ewing probe
XM 45CT- 3139.466713.3333-3545107152350.891351Ewing probe
XM 46CT- 3239.583312.8833-3590168122370.891091Ewing probe
XM 47CT- 5040.466712.1667-341693186130.931731Ewing probe
XM 48CT- 5341.500011.9833-35028556121.03581Ewing probe
XM 49CT- 5440.083312.1833-3617115182230.901641Ewing probe
XM 50CT- 5540.350011.2667-2889126134250.961291Ewing probe
XM 51CT- 7839.400010.6833-2785127126241.011271Ewing probe
XM 52CT- 7939.183313.0000-3441105158250.891411Ewing probe
XM 53C9-13140.316712.5500-3579103320.94301Ewing probe
XM 54C9-13240.766711.1167-2338144621.04651Ewing probe
XM 55C9-13341.55008.0167-2699104641.28811Ewing probe
XM 56C9-13441.98336.9000-2703124751.16871Ewing probe
XM 57C9-13541.61675.3000-239562561.04581Ewing probe
XM 58C9-13639.05004.4333-2332114641.26811Ewing probe
XM 59C9-13738.40003.9667-2659124721.22881Ewing probe
XM 60C9-13837.20001.9667-27831131121.181321Ewing probe
XM 61C9-13937.83330.7333-2701123481.18571Ewing probe
XM 62C9-14036.1667-2.0167-1286103311.07331Ewing probe
XM 63C9-14135.9833-4.0333-1375113951.02931Ewing probe
XM 64C9-11532.966732.4000-1398114401.09441Ewing probe
XM 65C9-11633.833332.2667-2641122290.87251Ewing probe
XM 66C9-11733.733330.1167-277592290.93271Ewing probe
XM 67C9-11833.766727.9000-262292181.05191Ewing probe
XM 68C9-11934.316727.1833-2627101110.94101Ewing probe
XM 69C9-12134.500023.4167-269042540.95511Ewing probe
XM 70C9-12334.483320.0667-286072291.11321Ewing probe
XM 71C9-12433.950019.2167-3889113341.04351Ewing probe
XM 72C9-12535.800019.4167-330462331.11371Ewing probe
XM 73C9-12636.183319.5167-329072661.10731Ewing probe
XM 74C9-12736.866719.6500-337393281.10311Ewing probe
XM 75C9-12938.183317.9667-2348123131.04141Ewing probe