Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

von Herzen, Richard P; Simmons, G (1972): Component parts of the World Heat Flow Data Collection [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.806260

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX Citation

Related to:
International Heat Flow Commission, I H F C (2012): Global Heat Flow Database. The Global Heat Flow Database of the International Heat Flow Commission (IHFC), University of North Dakota, USA; (data copied, 2012-10), https://ihfc-iugg.org/products/global-heat-flow-database/data
von Herzen, Richard P; Simmons, G (1972): Two heat flow profiles across the Atlantic Ocean. Earth and Planetary Science Letters, 15(1), 19-27, https://doi.org/10.1016/0012-821X(72)90024-6
Further details:
Jessop, Alan M; Hobart, Michael A; Sclater, John G (1976): The World Heat Flow Data Collection - 1975. Geological Survey of Canada, Earth Physics Branch, Geothermal Series, 5, 10 pp, hdl:10013/epic.40176.d002
Coverage:
Median Latitude: 1.872878 * Median Longitude: -19.235241 * South-bound Latitude: -23.516700 * West-bound Longitude: -63.383300 * North-bound Latitude: 30.900000 * East-bound Longitude: 11.916700
Minimum ELEVATION: -5980 m a.s.l. * Maximum ELEVATION: -1745 m a.s.l.
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
Sample, optional label/labor noLab novon Herzen, Richard P
LATITUDELatitudeGeocode
LONGITUDELongitudeGeocode
ELEVATIONElevationm a.s.l.Geocode
Depth, bottom/maxDepth botmvon Herzen, Richard PMaximum depth
Number of temperature dataNo Tempsvon Herzen, Richard P
Temperature gradientT gradmK/mvon Herzen, Richard P
Conductivity, averageCond averageW/m Kvon Herzen, Richard P
Heat flowHFmW/m2von Herzen, Richard P
10 NumberNovon Herzen, Richard PNumber of individual sites
11 Method commentMethod commvon Herzen, Richard P
Size:
839 data points

Data

Download dataset as tab-delimited text — use the following character encoding:


Lab no

Latitude

Longitude

Elevation [m a.s.l.]

Depth bot [m]

No Temps

T grad [mK/m]

Cond average [W/m K]

HF [mW/m2]
10 
No
11 
Method comm
A242-116.4500-21.7333-369543560.95531
A242-419.7500-29.0167-469593481.08521Ewing probe
A242-619.8667-31.9000-494093501.07541Ewing probe
A242-719.6500-34.4167-516585531.06571Ewing probe
A242-819.5167-36.5333-536575350.98341Ewing probe
A242-919.5333-38.8000-524574741.00751Ewing probe
A242-1119.5667-40.5000-567563260.98261Ewing probe
A242-1219.6167-41.6333-492062591.14681Ewing probe
A242-1319.6500-42.7333-40307271.1381Ewing probe
A242-1419.5667-43.8167-411065631.03651Ewing probe
A242-1519.5667-44.9500-3500332171.352921Ewing probe
A242-1619.6833-44.5500-405042891.08961Ewing probe
A242-1719.5617-46.1333-247564401.02411Ewing probe
A242-2019.5583-46.1100-270033721.00721Ewing probe
A242-2219.2667-47.4167-433053551.04571Ewing probe
A242-2319.2000-47.4183-433094191.03201Ewing probe
A242-26A19.2300-47.4283-433023321.04331Ewing probe
A24229B119.2717-47.3500-380533571.04601Ewing probe
A24229B219.2750-47.3467-382022311.04321Ewing probe
A24229B319.2800-47.3433-380512421.04441Ewing probe
A24229B419.2833-47.3400-370022571.04601Ewing probe
A24229B519.2883-47.3367-365022361.04381Ewing probe
A242-3019.1500-47.4367-395575391.07421Ewing probe
A242-31119.1533-47.4400-404033401.06421Ewing probe
A242-3219.6833-48.6500-4340432241.102471Ewing probe
A242-3320.0167-49.7667-465075241.02241Ewing probe
A242-3420.3500-50.8667-482074210.97211Ewing probe
A242-36120.6500-51.9333-530033610.86521Ewing probe
A242-36220.6500-51.9333-524023540.86461Ewing probe
A242-3721.0000-52.9333-468033230.94211Ewing probe
A242-3821.3167-53.9667-530075890.99881Ewing probe
A242-3921.7333-55.0000-530075650.97631Ewing probe
A242-4122.2333-56.6500-598095531.00541Ewing probe
A242-4327.2500-60.6167-564095500.93471Ewing probe
A242-4429.1000-62.0000-526095581.03591Ewing probe
A242-4530.9000-63.3833-503094501.00501Ewing probe
CH99-9-110.4833-18.3500-402533570.77431Ewing probe
CH99-9-210.4833-18.3500-402533550.77421Ewing probe
CH99-105.0833-19.5500-4525113750.82611Ewing probe
CH99-112.0500-20.6000-4635105790.89701Ewing probe
CH99-121-0.1500-19.1333-444533700.96661Ewing probe
CH99-122-0.1500-19.1333-444533550.96531Ewing probe
CH99-123-0.1500-19.1333-445033500.96471Ewing probe
CH99-131-2.2833-19.5500-5430331020.71721Ewing probe
CH99-132-2.2833-19.5500-5440221660.711181Ewing probe
CH99-14-2.5833-19.1000-54551252030.711451Ewing probe
CH99-15-4.5833-19.0500-4360122520.95491Ewing probe
CH99-16-6.6500-18.9167-4760115550.84461Ewing probe
CH99-181-8.4333-18.5667-431533790.98781Ewing probe
CH99-182-8.4333-18.5667-430533380.98371Ewing probe
CH99-183-8.4333-18.5667-431033290.98281Ewing probe
CH99-184-8.4333-18.5667-426533350.98341Ewing probe
CH99-19-8.2500-17.6667-4025104551.02561Ewing probe
CH99-201-8.1333-16.6000-377033580.98571Ewing probe
CH99-202-8.1333-16.6000-377533640.98631Ewing probe
CH99-203-8.1333-16.6000-378033650.98641Ewing probe
CH99-21-8.1667-15.4500-366094431.02441Ewing probe
CH99-22-7.4833-12.9667-328522670.98661Ewing probe
CH99-23A-6.7667-12.8000-328593141.00141Ewing probe
CH9924B1-7.3333-14.1000-369033490.99481Ewing probe
CH9924B2-7.3333-14.1000-369033400.99391Ewing probe
CH9924B3-7.3333-14.1000-369022430.99421Ewing probe
CH99-251-8.2500-13.3167-334033550.96521Ewing probe
CH99-252-8.2500-13.3167-334522590.96571Ewing probe
CH99-253-8.2500-13.3167-334022530.96511Ewing probe
CH99-26-8.3833-13.0667-3185123151.01151Ewing probe
CH99-271-8.6167-12.0500-308022510.96491Ewing probe
CH99-272-8.6167-12.0500-307522550.96531Ewing probe
CH99-273-8.6167-12.0500-308522570.96551Ewing probe
CH99-28-8.6667-10.9667-349084361.03371Ewing probe
CH99-29-8.6000-9.4167-3735125311.00311Ewing probe
CH99-30-8.6333-8.1000-411093581.03601Ewing probe
CH99-31-8.7167-6.4333-4375422230.741651Ewing probe
CH99-32-8.7167-4.9667-4470105380.97371Ewing probe
CH99-33-8.7000-3.5667-443083890.95851Ewing probe
CH99-34-8.7333-1.8833-4905115270.80211Ewing probe
CH99-351-8.7333-1.9000-478022290.75221Ewing probe
CH99-352-8.7333-1.9000-473033380.75291Ewing probe
CH99-355-8.7333-1.9000-476533450.75341Ewing probe
CH99-36-8.75000.1667-4915125630.87551Ewing probe
CH99-37-8.65002.0833-5695125860.75631Ewing probe
CH99-38-8.60004.4167-5390135810.70571Ewing probe
CH99-39-8.71676.5000-4935105660.90591Ewing probe
CH99-40-8.68338.5167-4510135660.74491Ewing probe
CH99-41-8.683310.4500-3845125600.80481Ewing probe
CH99-42-8.700011.8333-196563920.96881Ewing probe
CH99-431-8.700011.7667-227533650.75491Ewing probe
CH99-432-8.700011.7667-227533660.75501Ewing probe
CH99-433-8.700011.7667-227533630.75481Ewing probe
CH99-441-8.633311.8333-218533580.75441Ewing probe
CH99-442-8.633311.8333-218533600.75451Ewing probe
CH99-443-8.633311.8333-218533620.75471Ewing probe
CH99-451-8.700011.9167-1745111170.921081Ewing probe
CH99-453-8.700011.9167-1765211090.921001Ewing probe
CH99-46-8.850011.8167-2195124610.78471Ewing probe
CH99-471-8.783311.8333-1935331690.921551Ewing probe
CH99-473-8.783311.8333-1955231350.921241Ewing probe
CH99-48A-11.083310.7333-3950125700.77531Ewing probe
CH9948B1-11.066710.7500-393033710.76541Ewing probe
CH9948B2-11.066710.7500-393033660.76501Ewing probe
CH99-49-18.966710.0500-4145125740.75551Ewing probe
CH99-50-20.75009.9500-2625125510.91461Ewing probe
CH99-51-19.90009.3333-2340125480.91441Ewing probe
CH99-52-21.73338.5000-4335124550.96531Ewing probe
CH99-55-23.51676.4000-241533591.05621Ewing probe