Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

Fouquet, Yves; Zierenberg, Robert A; Miller, D Jay; Shipboard Scientific Party (2005): Thermal conductivity of ODP Hole 170-1039A [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.792692

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Related to:
Kimura, Gaku; Silver, E; Blum, Peter; et al. (1997): Proceedings of the Ocean Drilling Program, 170 Initial Reports. Proceedings of the Ocean Drilling Program, Ocean Drilling Program, 170, online, https://doi.org/10.2973/odp.proc.ir.170.1997
ODP/TAMU (2005): JANUS Database. Ocean Drilling Program, Texas A&M University, College Station TX 77845-9547, USA; (data copied from Janus 2005-02 to 2005-06), http://www-odp.tamu.edu/database/
Project(s):
Coverage:
Latitude: 9.639900 * Longitude: -86.200100
Date/Time Start: 1996-11-01T09:30:00 * Date/Time End: 1996-11-02T03:30:00
Minimum DEPTH, sediment/rock: 0.500 m * Maximum DEPTH, sediment/rock: 28.000 m
Event(s):
170-1039A * Latitude: 9.639900 * Longitude: -86.200100 * Date/Time Start: 1996-11-01T09:30:00 * Date/Time End: 1996-11-02T03:30:00 * Elevation: -4351.7 m * Penetration: 28 m * Recovery: 28.91 m * Location: Costa Rica subduction complex, North Pacific Ocean * Campaign: Leg170 * Basis: Joides Resolution * Method/Device: Drilling/drill rig (DRILL) * Comment: 3 cores; 28 m cored; 0 m drilled; 103.2 % recovery
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
DEPTH, sediment/rockDepth sedmGeocode – mbsf
Sample code/labelSample labelShipboard Scientific PartyDSDP/ODP/IODP sample designation
Conductivity, thermalkW/m/KShipboard Scientific Party
Probe TypeProbe TypeShipboard Scientific Party
IdentificationIDShipboard Scientific PartySystem ID
IdentificationIDShipboard Scientific PartyProbe ID
Size:
86 data points

Data

Download dataset as tab-delimited text — use the following character encoding:


Depth sed [m]
(mbsf)

Sample label

k [W/m/K]

Probe Type

ID
(System ID)

ID
(Probe ID)
0.500170-1039A-1H-1,50-500.8540FULL4365
2.000170-1039A-1H-2,50-500.9430FULL4364
3.500170-1039A-1H-3,50-500.8039FULL4365
5.000170-1039A-1H-4,50-500.7490FULL4367
6.500170-1039A-1H-5,50-500.8410FULL4369
8.000170-1039A-1H-6,50-500.7953FULL4370
9.500170-1039A-2H-1,50-500.8460FULL4
11.000170-1039A-2H-2,50-500.7750FULL4
12.500170-1039A-2H-3,50-500.6890FULL4
14.000170-1039A-2H-4,50-500.8060FULL4
15.500170-1039A-2H-5,50-500.8060FULL4
17.000170-1039A-2H-6,50-500.8793FULL4
18.500170-1039A-2H-7,50-500.8391FULL4
19.000170-1039A-3H-1,50-500.8458FULL4
20.500170-1039A-3H-2,50-500.7968FULL4
22.000170-1039A-3H-3,50-500.7752FULL4
23.500170-1039A-3H-4,50-500.8928FULL4
25.000170-1039A-3H-5,50-500.8080FULL4
26.500170-1039A-3H-6,50-500.7559FULL4
28.000170-1039A-3H-7,50-500.8040FULL4