Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

Martin, Ellen E; MacLeod, Kenneth G; Jiménez Berrocosco, Álvaro; Bourbon, Elodie (2012): (Table S1) Neodymium isotopes of fish teeth and hydroxylamine hydrochlorite extraction from ODP Site 207-1258 [dataset]. PANGAEA, https://doi.org/10.1594/PANGAEA.790820, In supplement to: Martin, EE et al. (2012): Water mass circulation on Demerara Rise during the Late Cretaceous based on Nd isotopes. Earth and Planetary Science Letters, 327-328, 111-120, https://doi.org/10.1016/j.epsl.2012.01.037

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Project(s):
Coverage:
Latitude: 9.433333 * Longitude: -54.733050
Date/Time Start: 2003-01-22T00:00:00 * Date/Time End: 2003-02-01T00:00:00
Minimum DEPTH, sediment/rock: 414.830 m * Maximum DEPTH, sediment/rock: 450.220 m
Event(s):
207-1258 * Latitude: 9.433333 * Longitude: -54.733050 * Date/Time Start: 2003-01-22T00:00:00 * Date/Time End: 2003-02-01T00:00:00 * Elevation: -3192.2 m * Penetration: 1393.4 m * Recovery: 882.7 m * Location: North Atlantic Ocean * Campaign: Leg207 * Basis: Joides Resolution * Method/Device: Composite Core (COMPCORE) * Comment: 141 cores; 1116.6 m cored; 276.8 m drilled; 79 % recovery
Comment:
Sediment depth is given in mcd. For further Nd values see MacLeod et al. (2008) datasets doi:10.1594/PANGAEA.722613; MacLeod et al. (2011) datasets doi:10.1594/PANGAEA.792572 and Jiménez Berrocoso et al. (2010) datasets: doi:10.1594/PANGAEA.792598.
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
1Sample code/labelSample labelMartin, Ellen E
2DEPTH, sediment/rockDepth sedmGeocode
3AGEAgeka BPGeocode
4Neodymium-143/Neodymium-144 ratio143Nd/144NdMartin, Ellen EMulti-collector inductively coupled plasma mass spectrometer (MC-ICP-MS)
5Neodymium-143/Neodymium-144 ratio, error143Nd/144Nd e±Martin, Ellen EMulti-collector inductively coupled plasma mass spectrometer (MC-ICP-MS)Two standard errors of the mean (2SE) are listed and have been used for quality control, such that values with errors greater than 0.000024 have been excluded. A 2s external error of +/-0.000014 (or 0.3 eNd units) based on replicate runs of JNdi-1.
6ε-Neodymium (0)ε-Nd(0)Martin, Ellen ECalculatede-Nd (0) = [143Nd/144Ndmeasured/143Nd/144NdCHUR -1] x 104, where 143Nd/144NdCHUR = 0.512638
7ε-Neodymium (T)ε-Nd(T)Martin, Ellen ECalculatede-Nd (T) was calculated using a value of 147Sm/144Nd = 0.110 for detrtital fractions and a value of 0.125 for HH fractions
Size:
85 data points

Download Data

Download dataset as tab-delimited text — use the following character encoding:

View dataset as HTML