Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

Henry, Pierre; Kanamatsu, Toshiya; Moe, Kyaw Thu; Expedition 333 Scientists (2012): Moisture and density (MAD) measured on IODP Hole 333-C0012G [dataset]. SIO7 Data Center, J-CORES Database; Ocean Drilling Program, Center for Deep Earth Exploration (JAMSTEC), PANGAEA, https://doi.org/10.1594/PANGAEA.786022

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Related to:
Henry, Pierre; Kanamatsu, Toshiya; Moe, Kyaw Thu; Expedition 333 Scientists (2011): NanTroSEIZE Stage 2: subduction inputs 2 and heat flow. Washington, DC (Integrated Ocean Drilling Program Management International, Inc.), 333, https://doi.org/10.2204/iodp.pr.333.2011
IODP/CDEX (2012): SIO7 Data Center, J-CORES Database. Ocean Drilling Program, Center for Deep Earth Exploration, Japan Agency for Marine-Earth Science and Technology, Yokohama Kanagawa 236-0001, JAPAN, https://www.jamstec.go.jp/sio7/j-cores.data/315/C0001H/
Other version:
IODP Hole 333-C0012G, snapshot taken on 2012-05-08, J-CORES, SIO7 Data Center [dataset]. https://www.jamstec.go.jp/sio7/j-cores.data/333/C0012G/
Coverage:
Latitude: 32.748080 * Longitude: 136.916922
Minimum DEPTH, sediment/rock: 515.730 m * Maximum DEPTH, sediment/rock: 625.790 m
Event(s):
333-C0012G * Latitude: 32.748080 * Longitude: 136.916922 * Elevation: -3510.5 m * Recovery: 25.92 m * Campaign: Exp333 (NanTroSEIZE Stage 2: Subduction Inputs 2 and Heat Flow) * Basis: Chikyu * Method/Device: Drilling/drill rig (DRILL)
Comment:
Geocode = [m CSF-A] Top Core depth (below sea floor)
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
Sample code/labelSample labelExpedition 333 ScientistsDSDP/ODP/IODP sample designationSample top
DEPTH, sediment/rockDepth sedmGeocode
Depth, top/minDepth topmExpedition 333 Scientists[m CSF-B] Top Core depth (below sea floor)
Sample code/label 2Sample label 2Expedition 333 ScientistsDSDP/ODP/IODP sample designationSample bottom
Depth, bottom/maxDepth botmExpedition 333 Scientists[m CSF-A] Bottom Core depth (below sea floor)
Depth, bottom/maxDepth botmExpedition 333 Scientists[m CSF-B] Bottom Core depth (below sea floor)
Sample volumeSamp volcm3Expedition 333 Scientists
Time StampTime StampExpedition 333 ScientistsOf sampling
Wet massWet mgExpedition 333 Scientists
10 Sample, dry massSamp dmgExpedition 333 Scientists
11 Mass, porewaterMass pwgExpedition 333 ScientistsIODP Method C (Blum, 1997)
12 Volume, porewaterVol pwcm3Expedition 333 ScientistsIODP Method C (Blum, 1997)
13 Mass, solidsMass solidsgExpedition 333 ScientistsIODP Method C (Blum, 1997)
14 Volume, wet sampleVol wet samplecm3Expedition 333 ScientistsCalculated
15 Volume, dry sampleVol dry samplecm3Expedition 333 ScientistsIODP Method C (Blum, 1997)
16 Salt contentSaltgExpedition 333 ScientistsIODP Method C (Blum, 1997)
17 Volume, saltVol saltcm3Expedition 333 ScientistsIODP Method C (Blum, 1997)
18 Volume, solidsVol solidscm3Expedition 333 ScientistsIODP Method C (Blum, 1997)
19 Water content, wet massWater wm%Expedition 333 ScientistsCalculated
20 Water content, dry massWater dm%Expedition 333 ScientistsCalculated
21 DensityDensityg/cm3Expedition 333 ScientistsCalculated (Blum, 1997)
22 Density, dry bulkDBDg/cm3Expedition 333 ScientistsCalculated (Blum, 1997)
23 Density, grainDensity graing/cm3Expedition 333 ScientistsCalculated (Blum, 1997)
24 Porosity, fractionalPoros fracExpedition 333 ScientistsIODP Method C (Blum, 1997)
25 Void Ratio descriptionVoid RatioExpedition 333 ScientistsCalculated (Blum, 1997)
26 Time StampTime StampExpedition 333 ScientistsOf analysing
Size:
450 data points

Data

Download dataset as tab-delimited text — use the following character encoding:


Sample label
(Sample top, DSDP/ODP/IODP sam...)

Depth sed [m]

Depth top [m]
([m CSF-B] Top Core depth (bel...)

Sample label 2
(Sample bottom, DSDP/ODP/IODP ...)

Depth bot [m]
([m CSF-A] Bottom Core depth (...)

Depth bot [m]
([m CSF-B] Bottom Core depth (...)

Samp vol [cm3]

Time Stamp
(Of sampling)

Wet m [g]
10 
Samp dm [g]
11 
Mass pw [g]
(IODP Method C (Blum, 1997))
12 
Vol pw [cm3]
(IODP Method C (Blum, 1997))
13 
Mass solids [g]
(IODP Method C (Blum, 1997))
14 
Vol wet sample [cm3]
(Calculated)
15 
Vol dry sample [cm3]
(IODP Method C (Blum, 1997))
16 
Salt [g]
(IODP Method C (Blum, 1997))
17 
Vol salt [cm3]
(IODP Method C (Blum, 1997))
18 
Vol solids [cm3]
(IODP Method C (Blum, 1997))
19 
Water wm [%]
(Calculated)
20 
Water dm [%]
(Calculated)
21 
Density [g/cm3]
(Calculated (Blum, 1997))
22 
DBD [g/cm3]
(Calculated (Blum, 1997))
23 
Density grain [g/cm3]
(Calculated (Blum, 1997))
24 
Poros frac
(IODP Method C (Blum, 1997))
25 
Void Ratio
(Calculated (Blum, 1997))
26 
Time Stamp
(Of analysing)
333-C0012G-1R-1,73.0515.730515.730333-C0012G-1R-1,75.0515.750515.75052011-01-05T21:30:257.27815.87351.45551.42142.18353.60492.20640.05090.02295.82260.20000.25002.01891.61522.66660.39430.6512011-01-09T22:55:15
333-C0012G-1R-2,4.0516.050516.050333-C0012G-1R-2,6.0516.070516.07052011-01-05T21:30:258.18116.90191.32561.29452.51613.81062.53700.04640.02096.85550.16200.19342.14691.79912.72470.33970.51452011-01-09T22:55:16
333-C0012G-1R-3,49.0517.080517.080333-C0012G-1R-3,51.0517.100517.10032011-01-05T10:23:407.40545.96581.49181.45682.15773.61452.18120.05220.02355.91360.20140.25232.04881.63612.74070.40300.67522011-01-09T22:55:15
333-C0012G-1R-4,51.0517.610517.610333-C0012G-1R-4,53.0517.630517.63052011-01-05T21:30:258.04236.93411.14841.12152.52913.65062.54720.04020.01816.89390.14280.16662.20301.88842.72580.30720.44342011-01-09T22:55:16
333-C0012G-1R-4,101.5518.115518.115333-C0012G-1R-4,104.5518.145518.14552011-01-05T15:38:507.62956.44581.22661.19792.34013.53802.35940.04290.01936.40290.16080.19162.15641.80982.73620.33860.51192011-01-09T22:55:15
333-C0012G-2R-1,27.0524.770524.770333-C0012G-2R-1,29.0524.790524.79052011-01-05T21:34:037.40546.15991.29071.26042.19083.45122.21120.04520.02046.11470.17430.21112.14571.77182.79110.36520.57532011-01-09T22:55:16
333-C0012G-2R-2,134.0526.230526.230333-C0012G-2R-2,136.0526.250526.25052011-01-05T21:08:5616.267315.00931.30361.27305.16236.43535.18280.04560.020514.96370.08010.08712.52782.32532.89860.19780.24662011-01-09T22:55:16
333-C0012G-4R-1,29.5543.795543.795333-C0012G-4R-1,31.5543.815543.81552011-01-06T11:38:167.86596.70191.20621.17792.27373.45162.29270.04220.01906.65970.15330.18112.27891.92952.92900.34130.51812011-01-09T22:55:16
333-C0012G-5R-1,4.0553.040553.040333-C0012G-5R-1,6.0553.060553.06052011-01-06T23:24:3714.433512.86481.62561.58754.43486.02234.46040.05690.025612.80790.11260.12692.39672.12672.88800.26360.3582011-01-09T22:55:16
333-C0012G-6R-CC,7.0563.305563.305333-C0012G-6R-CC,9.0563.325563.32552011-01-06T11:35:3114.032112.79081.28631.25624.45905.71524.47930.04500.020312.74580.09170.10092.45522.23022.85840.21980.28172011-01-09T22:55:16
333-C0012G-7R-1,29.0572.290572.290333-C0012G-7R-1,31.0572.310572.31052011-01-06T15:37:4913.591012.80870.81070.79174.52945.32114.54220.02840.012812.78030.05960.06342.55422.40182.82160.14880.17482011-01-09T22:55:16
333-C0012G-8R-1,34.0581.840581.840333-C0012G-8R-1,36.0581.860581.86052011-01-06T21:53:3914.593014.00090.61360.59925.08145.68065.09110.02150.009713.97940.04200.04392.56892.46092.75110.10550.11792011-01-09T22:55:16
333-C0012G-9R-1,8.0591.080591.080333-C0012G-9R-1,10.0591.100591.10052011-01-07T05:56:1915.734115.19990.55360.54065.42135.96195.43000.01940.008715.18050.03520.03652.63912.54632.80020.09070.09972011-01-09T22:55:16
333-C0012G-10R-2,118.0597.465597.465333-C0012G-10R-2,120.0597.485597.48572011-01-07T09:06:0316.465615.53130.96820.94555.55116.49665.56640.03390.015315.49740.05880.06252.53452.38552.79180.14550.17032011-01-09T22:55:16
333-C0012G-12R-2,91.0612.920612.920333-C0012G-12R-2,93.0612.940612.94052011-01-07T16:58:3316.384915.25781.16801.14065.20746.34805.22580.04090.018415.21690.07130.07682.58112.39712.92220.17970.2192011-01-09T22:55:16
333-C0012G-13R-1,121.0616.710616.710333-C0012G-13R-1,123.0616.730616.73052011-01-07T17:12:3715.605214.62391.01690.99315.26316.25625.27910.03560.016014.58830.06520.06972.49442.33182.77180.15870.18872011-01-09T22:55:16
333-C0012G-14R-1,22.0620.720620.720333-C0012G-14R-1,24.0620.740620.74052011-01-07T17:18:5413.820812.38561.48731.45244.33065.78304.35410.05210.023512.33350.10760.12062.38992.13272.84800.25110.33542011-01-09T22:55:16
333-C0012G-15R-1,29.0625.790625.790333-C0012G-15R-1,31.0625.810625.81052011-01-07T18:43:5110.57369.88100.71770.70093.55294.25383.56420.02510.01139.85590.06790.07282.48572.31702.77400.16480.19732011-01-09T22:55:17