Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

Henry, Pierre; Kanamatsu, Toshiya; Moe, Kyaw Thu; Expedition 333 Scientists (2012): XRF-core logger measurements from IODP Hole 333-C0012D [dataset]. SIO7 Data Center, J-CORES Database; Ocean Drilling Program, Center for Deep Earth Exploration (JAMSTEC), PANGAEA, https://doi.org/10.1594/PANGAEA.785037

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Related to:
Henry, Pierre; Kanamatsu, Toshiya; Moe, Kyaw Thu; Expedition 333 Scientists (2011): NanTroSEIZE Stage 2: subduction inputs 2 and heat flow. Washington, DC (Integrated Ocean Drilling Program Management International, Inc.), 333, https://doi.org/10.2204/iodp.pr.333.2011
IODP/CDEX (2012): SIO7 Data Center, J-CORES Database. Ocean Drilling Program, Center for Deep Earth Exploration, Japan Agency for Marine-Earth Science and Technology, Yokohama Kanagawa 236-0001, JAPAN, https://www.jamstec.go.jp/sio7/j-cores.data/315/C0001H/
Other version:
IODP Hole 333-C0012D, snapshot taken on 2012-05-08, J-CORES, SIO7 Data Center [dataset]. https://www.jamstec.go.jp/sio7/j-cores.data/333/C0012D/
Coverage:
Latitude: 32.748335 * Longitude: 136.917363
Minimum DEPTH, sediment/rock: 0.792 m * Maximum DEPTH, sediment/rock: 178.878 m
Event(s):
333-C0012D * Latitude: 32.748335 * Longitude: 136.917363 * Elevation: -3510.5 m * Recovery: 66.38 m * Campaign: Exp333 (NanTroSEIZE Stage 2: Subduction Inputs 2 and Heat Flow) * Basis: Chikyu * Method/Device: Drilling/drill rig (DRILL)
Comment:
Geocode = [m CSF-A] Top Core depth (below sea floor)
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
Sample code/labelSample labelExpedition 333 ScientistsDSDP/ODP/IODP sample designation
DEPTH, sediment/rockDepth sedmGeocode
Depth, top/minDepth topmExpedition 333 Scientists[m CSF-B] Top Core depth (below sea floor)
Aluminium oxideAl2O3%Expedition 333 ScientistsX-ray fluorescence (XRF)
Calcium oxideCaO%Expedition 333 ScientistsX-ray fluorescence (XRF)
Iron oxide, Fe2O3Fe2O3%Expedition 333 ScientistsX-ray fluorescence (XRF)
Potassium oxideK2O%Expedition 333 ScientistsX-ray fluorescence (XRF)
Magnesium oxideMgO%Expedition 333 ScientistsX-ray fluorescence (XRF)
Manganese oxideMnO%Expedition 333 ScientistsX-ray fluorescence (XRF)
10 Sodium oxideNa2O%Expedition 333 ScientistsX-ray fluorescence (XRF)
11 Phosphorus pentoxideP2O5%Expedition 333 ScientistsX-ray fluorescence (XRF)
12 Silicon dioxideSiO2%Expedition 333 ScientistsX-ray fluorescence (XRF)
13 Titanium dioxideTiO2%Expedition 333 ScientistsX-ray fluorescence (XRF)
14 Loss on ignitionLOI%Expedition 333 ScientistsMuffel furnace
15 Time StampTime StampExpedition 333 ScientistsXRF registration
Size:
196 data points

Data

Download dataset as tab-delimited text — use the following character encoding:


Sample label

Depth sed [m]

Depth top [m]

Al2O3 [%]

CaO [%]

Fe2O3 [%]

K2O [%]

MgO [%]

MnO [%]
10 
Na2O [%]
11 
P2O5 [%]
12 
SiO2 [%]
13 
TiO2 [%]
14 
LOI [%]
15 
Time Stamp
333-C0012D-1H-2,21.00.7920.80514.11510.9465.8762.5142.6430.0563.1090.10457.2270.52612.1160184602011-01-03T13:21:17
333-C0012D-1H-2,21.1119.739120.06016.8483.7525.7953.2332.4210.1762.6070.08462.2350.6617.7213878822011-01-03T13:21:17
333-C0012D-1H-2,21.2129.479129.63017.0213.5135.8913.1142.4850.2162.7070.09562.1310.6837.6823306402011-01-03T13:21:17
333-C0012D-1H-2,21.3137.546138.24516.7401.0576.3443.3452.4500.1182.7000.08664.8750.6795.3833005172011-01-03T13:21:17
333-C0012D-1H-2,21.4144.637145.04016.4450.8536.1423.3462.4020.1432.4840.07864.7980.6735.1309475632011-01-05T08:37:20
333-C0012D-1H-2,21.5150.217151.17016.6161.9826.4163.2592.4990.1912.3770.09463.3260.6915.8439923462011-01-05T08:37:20
333-C0012D-1H-2,21.6154.843155.06517.1191.0486.6983.0302.6060.0992.5810.07663.8990.6915.3040662112011-01-03T13:21:17
333-C0012D-1H-2,21.7160.561160.69016.9951.5895.8513.4382.5210.1132.5800.09664.2500.7045.9801405782011-01-03T13:21:17
333-C0012D-1H-2,21.8165.278165.94517.1450.8395.9163.4722.4790.2122.3400.09164.8900.6834.9654473172011-01-05T08:37:20
333-C0012D-1H-2,21.9168.512169.83016.6041.5636.0493.3722.4700.1762.4550.09364.0860.6745.5742092462011-01-03T13:21:17
333-C0012D-1H-2,21.10171.458172.19516.7431.1345.8583.2802.3560.1062.5690.07765.0580.6784.9385251162011-01-03T13:21:17
333-C0012D-1H-2,21.11174.000174.21016.6924.5205.2871.3751.6910.0703.2470.10663.3340.6373.7793071272011-01-05T08:37:20
333-C0012D-1H-2,21.12174.447174.84515.1427.7935.4422.9512.1310.7372.4420.14460.7320.5959.7321776682011-01-05T08:37:20
333-C0012D-1H-2,21.13178.878180.23016.8024.8775.6842.3492.1790.0982.9170.09962.3030.7296.7600438372011-01-03T13:21:17