Not logged in
PANGAEA.
Data Publisher for Earth & Environmental Science

Henry, Pierre; Kanamatsu, Toshiya; Moe, Kyaw Thu; Expedition 333 Scientists (2012): XRF-core logger measurements from IODP Hole 333-C0012C [dataset]. SIO7 Data Center, J-CORES Database; Ocean Drilling Program, Center for Deep Earth Exploration (JAMSTEC), PANGAEA, https://doi.org/10.1594/PANGAEA.784999

Always quote citation above when using data! You can download the citation in several formats below.

RIS CitationBibTeX CitationShow MapGoogle Earth

Related to:
Henry, Pierre; Kanamatsu, Toshiya; Moe, Kyaw Thu; Expedition 333 Scientists (2011): NanTroSEIZE Stage 2: subduction inputs 2 and heat flow. Washington, DC (Integrated Ocean Drilling Program Management International, Inc.), 333, https://doi.org/10.2204/iodp.pr.333.2011
IODP/CDEX (2012): SIO7 Data Center, J-CORES Database. Ocean Drilling Program, Center for Deep Earth Exploration, Japan Agency for Marine-Earth Science and Technology, Yokohama Kanagawa 236-0001, JAPAN, https://www.jamstec.go.jp/sio7/j-cores.data/315/C0001H/
Other version:
IODP Hole 333-C0012C, snapshot taken on 2012-05-08, J-CORES, SIO7 Data Center [dataset]. https://www.jamstec.go.jp/sio7/j-cores.data/333/C0012C/
Coverage:
Latitude: 32.748245 * Longitude: 136.917362
Minimum DEPTH, sediment/rock: 2.545 m * Maximum DEPTH, sediment/rock: 120.560 m
Event(s):
333-C0012C * Latitude: 32.748245 * Longitude: 136.917362 * Elevation: -3510.5 m * Recovery: 128.62 m * Campaign: Exp333 (NanTroSEIZE Stage 2: Subduction Inputs 2 and Heat Flow) * Basis: Chikyu * Method/Device: Drilling/drill rig (DRILL)
Comment:
Geocode = [m CSF-A] Top Core depth (below sea floor)
Parameter(s):
#NameShort NameUnitPrincipal InvestigatorMethod/DeviceComment
Sample code/labelSample labelExpedition 333 ScientistsDSDP/ODP/IODP sample designation
DEPTH, sediment/rockDepth sedmGeocode
Depth, top/minDepth topmExpedition 333 Scientists[m CSF-B] Top Core depth (below sea floor)
Calcium oxideCaO%Expedition 333 ScientistsX-ray fluorescence (XRF)
Iron oxide, Fe2O3Fe2O3%Expedition 333 ScientistsX-ray fluorescence (XRF)
Potassium oxideK2O%Expedition 333 ScientistsX-ray fluorescence (XRF)
Magnesium oxideMgO%Expedition 333 ScientistsX-ray fluorescence (XRF)
Manganese oxideMnO%Expedition 333 ScientistsX-ray fluorescence (XRF)
Sodium oxideNa2O%Expedition 333 ScientistsX-ray fluorescence (XRF)
10 Phosphorus pentoxideP2O5%Expedition 333 ScientistsX-ray fluorescence (XRF)
11 Silicon dioxideSiO2%Expedition 333 ScientistsX-ray fluorescence (XRF)
12 Titanium dioxideTiO2%Expedition 333 ScientistsX-ray fluorescence (XRF)
13 Loss on ignitionLOI%Expedition 333 ScientistsMuffel furnace
14 Time StampTime StampExpedition 333 ScientistsXRF registration
Size:
234 data points

Data

Download dataset as tab-delimited text — use the following character encoding:


Sample label

Depth sed [m]

Depth top [m]

CaO [%]

Fe2O3 [%]

K2O [%]

MgO [%]

MnO [%]

Na2O [%]
10 
P2O5 [%]
11 
SiO2 [%]
12 
TiO2 [%]
13 
LOI [%]
14 
Time Stamp
333-C0012C-1H-2,21.02.5452.3968.8465.6252.6692.2380.0723.5380.12559.3800.61510.0919865602011-01-02T06:35:29
333-C0012C-1H-2,21.13.7603.54010.8696.6522.5352.9050.0573.1770.10056.9340.60912.6774912402011-01-01T17:57:27
333-C0012C-1H-2,21.27.2107.05912.1155.5812.5632.6650.0642.9120.10856.8560.63413.5552784302011-01-02T06:35:29
333-C0012C-1H-2,21.39.4359.1607.0776.6482.8252.9330.0543.2600.11159.7730.6439.9032940472011-01-01T17:57:27
333-C0012C-1H-2,21.412.35511.9183.1996.3783.1412.8970.0553.5140.09661.1540.7018.0959829992011-01-02T06:35:29
333-C0012C-1H-2,21.517.57017.3583.9656.9323.0162.8770.0653.7600.09760.8620.6798.9309596702011-01-02T06:35:29
333-C0012C-1H-2,21.627.96527.6791.5656.3543.2282.7280.0663.4230.09062.8330.6556.7452557362011-01-05T08:37:20
333-C0012C-1H-2,21.736.03535.9421.3296.8813.3222.8220.0633.4050.09162.4800.6837.0722269992011-01-01T17:57:27
333-C0012C-1H-2,21.846.97546.6601.4436.4923.1712.7410.0573.3490.08663.1950.7046.7144111512011-01-02T06:35:30
333-C0012C-1H-2,21.955.39555.1573.4936.2943.2672.6970.0783.1710.09260.5800.6998.2618595832011-01-05T08:37:20
333-C0012C-1H-2,21.1064.46564.1505.1446.1043.1682.6820.2943.1100.09759.7440.6879.4801819362011-01-01T17:57:27
333-C0012C-1H-2,21.1174.01573.9731.5706.0113.3082.6470.1133.1240.08962.5650.7206.6575383022011-01-02T06:35:30
333-C0012C-1H-2,21.1280.65080.4065.0066.5183.1772.6880.5542.7250.09062.4840.7108.9830270732011-01-05T08:37:19
333-C0012C-1H-2,21.1392.01091.7052.9876.5753.2792.5990.2822.8070.09361.8220.6777.4351782952011-01-01T17:57:27
333-C0012C-1H-2,21.1497.19096.8907.4455.8402.9952.4310.3052.6250.09159.3530.6589.9327735632011-01-06T01:27:34
333-C0012C-1H-2,21.15106.245105.32512.1355.5862.5882.1730.6822.2830.27955.5770.63612.8103664502011-01-02T06:35:29
333-C0012C-1H-2,21.16108.615108.5595.6836.1503.0302.3710.1972.4860.08760.8610.6879.1130181982011-01-02T06:35:29
333-C0012C-1H-2,21.17120.560119.5594.6275.7633.1842.3640.6062.5480.09761.2390.6698.4767447692011-01-02T06:35:29